Installation and operating instructions for oven

18
GB
Electrical connection to the controller
The sauna equipment (sauna oven, control unit and
light, etc.) may only be connected to the mains
supply by a locally authorized electrician using a
permanent connection. All the connection cables
installed inside the booth must be suitable for an
ambient temperature of at least 140°C. Silicon
cables are ideal for this purpose. If single-core
cables are used to make the connection, these must
be protected by a pliable metal tube. The minimum
cross-section of the connection cable and the
minimum size of the sauna booth are listed in the
following table.
The electrical connection is to be made as shown in
the connection diagram. There is a connection
diagram on the inside of the connection cover.
Please note that live cables should not be installed
on the inside of the booth for safety reasons. For this
reason most sauna booths have empty tubes for
cable installation in the wall element with the air
intake opening.
If your booth does not have any empty tubes, drill a
hole approximately 10 - 12 mm in diameter in the
wall of the booth immediately next to the oven at the
point where the cable comes out of the oven and
thread the cable through this hole to the outside and
then route it to the control unit. The cable and all
other connection cables (supply cables to the mains
and to the booth light) should also be protected from
damage on the outside of the booth. This protection
may take the form of installation tubes or strips of
wood.
Oven type Connection Suitable for Minimum cross-sections mm
2
(copper cable)
rating booth size SHG 7.5 -9.0 kW: Connect to 400 V AC 3N
in kW in m
3
SHG 3.6 kW: Connect to 230 V 1N
Mains cable Oven connection Fuse in
from mains to cable from control A
control unit unit to oven (silicon)
SHG 3,6 kW 3,6 approx. 4 - 6 3 x 1,5 3 x 1,5 16
SHG 7,5 kW 7,5 approx.. 8 - 12 5 x 2,5 5 x 1,5 16
SHG 9,0 kW 9,0 approx. 10 - 14 5 x 2,5 5 x 1,5 16
SHG 7,5 kW 7,5 approx. 8 - 12 5 x 2,5 7 x 1,5 20
+ 1,5 kW
with evaporator
SHG 9,0 kW 9,0 approx. 10 - 14 5 x 2,5 7 x 1,5 20
+ 1,5 kW
with evaporator