Ear and Forehead Thermometer INSTRUCTION MANUAL Item No. 91807 19.PJN174-14_GA-USA_HHD-Ohrthermometer_DSO364_28.07.14 Montag, 28.
TABLE OF CONTENTS USA D No. Topic Page Definition of symbols 5 2.0 Application and functionality 6 2.1 Intended use 6 2.2 Field of application 7 3.0 Safety instructions 7 3.1 General safety instructions 7 3.3 Environment for which the DSO 364 device is not suited 9 1.0 3.4 Usage by children and adolescents 10 3.5 Information on the application of the device 10 4.0 Questions concerning body temperature 13 4.1 What is body temperature? 13 4.
TABLE OF CONTENTS No. Topic USA Page 8.3 Backlighting / torch function 21 8.4 Energy saving mode 22 8.5 Setting °Celsius / °Fahrenheit 22 9.0 Display / setting time and date 23 9.1 Display of time and date 23 9.2 Setting time and date 23 10.0 Memory mode 26 11.0 Measuring the temperature in the ear 28 12.0 Measuring the temperature on the forehead 30 13.0 Object temperature measurement 32 14.0 Disposal of the device 33 15.
BASIC INFORMATION USA D Thank you for purchasing Ear and Forehead Thermometer. For safe use of this product, be sure to read and fully understand this manual as well as the safety precautions, prior to any use. Please keep this manual safely stored for convenient reference. The device is intended for the intermittent measurement and monitoring of human body temperature by consumers in the home.
BASIC INFORMATION USA 1.0 Definition of symbols The safety symbols shown in this instruction manual contain information concerning the correct use of the device and your safety.
USA D BASIC INFORMATION 2.0 Application and functionality The Ear and Forehead Thermometer is an infrared temperature measurement device with which you can easily and straightforwardly carry out precise measurements of the body temperature on the forehead or in the ear as well as the temperature of liquids or surfaces. An acoustic signal indicates the end of the temperature measurement; then, you can read the temperature measured on the LCD display.
SAFETY INSTRUCTIONS USA 2.2 Field of application This device is intended to be used and applied only in a domestic environment, but it is not suitable for commercial usage. 3.0 Safety instructions 3.1 General safety instructions 3.1.1 In case of a defect, the device must not be used. Do not try to modify (change), disassemble or repair the device or replace any parts. 3.1.2 If irregularities occur during the use of the device, you must stop the application immediately and seek medical advice. 3.1.
USA D SAFETY INSTRUCTIONS 3.1.8 Do not drop the device, do not shake it and do not expose it to any impacts. 3.1.9 In order to ensure precise measurement results, particularly protect the infrared sensor of the device against moisture, dirt and damage. 3.2.0 Do not expose the device to direct sunlight and excessively high or low temperatures. Use and store the device only in dry environments free from any contamination. 3.2.
SAFETY INSTRUCTIONS USA 3.3 Environment for which the DSO 364 device is not suited 3.3.1 Do not use the device in damp and wet environments. Keep the device away from any liquids while in use and, above all, never immerse it in liquids. 3.3.2 Do not use the device near highly flammable substances or gases or near explosives. 3.3.3 While using the device, it may interfere with other electric devices or may be impaired by other electric devices. Therefore, do not use the device near other electric devices.
USA D SAFETY INSTRUCTIONS 3.4 Usage by children and adolescents 3.4.1 The device must be stored out of the reach of children and adolescents younger than 18 years. 3.4.2 Supervise children in order to prevent them from playing with the device. 3.4.3 Keep the device out of the reach of children. Small parts or batteries could be swallowed by children who might then choke. Children could hurt themselves when using the device. 3.5 Information on the application of the device 3.5.
SAFETY INSTRUCTIONS USA 3.5.5 Do not use the device if it is damaged. Using a damaged device might result in injuries, serious risks and inaccurate measurement results. 3.5.6 Do not perform any measurements in the ear if you suffer from an ear disease or if there is still water in the ear (e.g. after having taken a shower, after swimming...). 3.5.7 Earwax or oily skin on the forehead might result in inaccurate measurements. Therefore, clean the ear and / or the forehead before carrying out a measurement.
USA D SAFETY INSTRUCTIONS 3.6.1 If ear drops or other medication were administered in one ear, the measurement of the body temperature should be carried out in the other ear. 3.6.2 Babies and toddlers have a higher body temperature than adults. With increasing age, the body temperature decreases. In most cases, temperature fluctuations are higher for children and occur more quickly and more frequently. 3.6.
BODY TEMPERATURE USA 4.0 Questions concerning body temperature 4.1 What is body temperature? The body temperature is the internal temperature of the body (core temperature). It fluctuates during the course of the day and is lowest in the early morning and highest in the late afternoon. The normal value of the body temperature is not a fixed value, but rather a temperature range. In general, the body temperature decreases with increasing age.
USA D BODY TEMPERATURE Measurements performed on different parts of the human body produce different results: Usually, the body temperature measured rectally is approx. 0.5 °F / 0.3 °C higher than the body temperature measured in the mouth, and this, in turn, is 0.5 °F / 0.3 °C higher than the body temperature measured in the armpit.
BODY TEMPERATURE USA 4.3 Information on measuring the body temperature in the ear For babies younger than 12 months: Gently pull the ear slightly diagonally backwards in order to straighten the ear canal. Carefully insert the measuring probe into the ear canal in order to ensure that the measuring probe is directed towards the eardrum (see Fig. 3).
USA D SCOPE OF DELIVERY 5.0 Scope of delivery / contents 1x instruction manual 1x Ear and Forehead Thermometer DSO 364 with stand 2x AAA batteries 16 19.PJN174-14_GA-USA_HHD-Ohrthermometer_DSO364_28.07.14 Montag, 28.
DESIGNATION OF THE PARTS USA 6.0 Designation of device parts 1. LCD display 2. Backlighting green / red as temperature range indicator and “Cleaning” warning indicator 3. MEM button to recall the measured values saved 4. SET button to set date / time 5. ( ) button to switch on the torch 6. ( ) button to measure the temperature in the ear 7. ( ) button to measure the temperature on the forehead 8. Measuring tip with infrared sensor 9. Plug-on attachment for measuring the temperature on the forehead 10.
USA D LCD DISPLAY 7.0 LCD display 1. Segment display of the temperature measured 2. Segment display for FE (fever indicator) and CL (“Cleaning” warning indicator) 3. Symbol PM (“post meridiem” = in the afternoon if the time is displayed in the 12-hour mode) 4. Symbol “Memory” ( ) when recalling the memory ) for “weak batteries”: change 5. Symbol ( batteries 6. Symbol ( ) for measuring the temperature on an object (liquids / surfaces) 7. Symbol ( ) for measuring the temperature in the ear 8.
BASIC FUNCTIONS USA 8.0 Basic functions 8.1 Commissioning of the device The two batteries have already been inserted in the device, but are protected by means of an insulating strip. Before using the device for the first time, open the cover of the battery compartment on the rear Fig. 4 side of the device (see also page 34). Remove the insulating strip as shown in Fig. 4 and close the cover of the battery compartment. Now, the device switches on with 4 short acoustic signals and, on the LCD Fig.
USA D BASIC FUNCTIONS if you hold the device in such a manner that the front side with the buttons is facing the user. In the temperature measurement mode and in the memory mode, it is the other way round: In this case, the display is in the correct position if you hold the device in such a manner that the rear side is facing the user.
BASIC FUNCTIONS USA 8.2 Warning indicator if the body temperature is too high The device is equipped with a backlighting, which immediately indicates by means of different colours after the body temperature has been measured in which range the body temperature is: Green backlighting: the body temperature measured is below 99.5 °F (37.5 °C) Red backlighting: the body temperature measured is in the elevated temperature range from 99.5 °F (37.5 °C) to 100.3 °F (37.
USA D BASIC FUNCTIONS 8.4 Energy saving mode By default, the device has been set in such a way that it switches to the standby mode (time, date and ambient temperature are shown alternately) approx. 30 - 60 seconds, depending on the respective mode, after the last button has been pressed. If you wish that the device switches off completely after approx. 1 minute, you can proceed as follows: Press the SET button in the standby mode and keep it pressed for approx.
TIME AND DATE USA 9.0 Display / setting time and date 9.1 Display of time and date In the standby mode and in the memory mode, the device alternately shows ambient temperature (°C or °F), time (hours / minutes) in the 24hour or 12-hour mode (PM) and date (month / weekday). The two flashing points between the hour and minute display signal intervals of one second. 9.2 Setting time and date Step 1: Press the SET button and keep it pressed for approx. 2 seconds in order to access the setting mode.
USA D TIME AND DATE Step 4: On the display, the minute display flashes now and you can set the value from 00 to 59 by pressing the MEM button and save the value set by pressing the SET button. Step 5: On the display, the calendar year display flashes now and you can set the value from 2001 to 2099 by pressing the MEM button and save the value set by pressing the SET button.
TIME AND DATE USA PLEASE NOTE: If you press the MEM button when setting the date and time values, the respectively next higher value is set. If you press the MEM button and keep it pressed, the values which can be set are shown quickly one after another. This facilitates setting the values if a larger number of values which can be set is available. If you release the MEM button, the setting remains at the respectively reached value.
USA D MEMORY MODE 10.0 Memory mode The device saves the last 9 body temperature measurements carried out in the ear or on the forehead in the memory, with the current measurement being shown last in the memory. If all 9 memory locations are occupied, the oldest measurement is deleted from the memory. In the standby mode, hold the device in order to display the measured data saved in such a manner that the rear side of the device is facing you and press the MEM button (see Fig. 6).
MEMORY MODE USA been reached, the display switches back to the standby mode after the MEM button has been pressed once again and returns to the most recent entry only after the MEM button has been pressed once more (e.g. 8, see Fig. 7 on page 26) etc. PLEASE NOTE: If no measured values have been saved, the (-- -°C) display with the ( ) symbol is shown on the display.
TEMPERATURE MEASUREMENT USA D 11.0 Measuring the temperature in the ear Step 1: Before measuring the temperature in the ear, remove the plug-on attachment for measuring the temperature on the forehead (9) from the device. Prior to the measurement, check if the infrared sensor is clean. Hold the device as shown in Fig. 11 with your thumb or index finger on the ( ) “Ear measurement” button, but do not press the ( ) button yet.
TEMPERATURE MEASUREMENT USA Step 3: Keep the device still and then press the ( ) “Ear measurement” button (see Fig. 15). A single acoustic signal indicates that the measurement has been started. After approx. 2 seconds, two acoustic Fig. 15 signals confirm that the temperature measurement has been completed. The ( ) symbol and the ear temperature measured are shown on the display (e.g. as shown in Fig. 16). At the same time, the backlighting Fig.
USA D TEMPERATURE MEASUREMENT 12.0 Measuring the temperature on the forehead Step 1: Put the plug-on attachment for measuring the temperature on the forehead (9) firmly on the device. Prior to the measurement, check if the infrared sensor is clean. Hold the device as shown in Fig. 17 with your thumb on the ( ) “Forehead measurement” button, but do not press the ( ) button yet. Step 2: Hold the device to the middle of the forehead (see Fig.
TEMPERATURE MEASUREMENT USA temperature in the range from 99.5 °F to 100,3 °F (single acoustic signal and red flashing light / approx. every 2 seconds) or if the body temperature is in the fever range from 100.4 °F to 109,3 °F (two acoustic signals and red flashing light at intervals of one second; in addition to this, FE (for fever) is shown on the display). PLEASE NOTE: The corresponding temperature values in °C (degree Celsius) can be found in section 8.2 on page 21).
USA D TEMPERATURE MEASUREMENT 13.0 Object temperature measurement Step 1: Before measuring the object temperature (liquid / surface), remove the plug-on attachment for measuring the temperature on the forehead (9) from the device. Prior to the measurement, check if the infrared sensor is clean. Simultaneously press the ( ) “Ear measurement” and ( ) “Forehead measurement” buttons.
DISPOSAL / BATTERY CHANGE USA PLEASE NOTE: If you wish to immediately return to the standby mode, you can simultaneously press the ( ) “Ear measurement” and ( ) “Forehead measurement” buttons. Returning to the standby mode is also carried out automatically if you do not press any button within a period of approx. 1 minute. 14.0 Disposal of the device Dispose of the DSO 364 forehead and ear thermometer according to the applicable local regulations and the EPA (Environmental Protection Agency / www.epa.
USA D DISPOSAL / BATTERY CHANGE 15.2 Battery types: For the Ear and Forehead Thermometer DSO 364, alkaline batteries of the type AAA are required. Do not use any rechargeable batteries! In order to open the cover of the battery compartment on the rear side of the device, press against the locking clip and remove the cover. Remove the used batteries. Then, insert two new alkaline batteries (size AAA).
DISPOSAL / BATTERY CHANGE USA 15.5 Batteries may be fatal if swallowed. Therefore, store batteries and products out of the reach of infants. If a battery was swallowed, seek medical advice immediately. 15.6 If a battery has leaked, avoid any contact with the skin, the eyes and the mucous membranes. Immediately rinse the affected parts with plenty of clear water and instantly consult a doctor or seek medical advice. 15.
USA D CLEANING AND CARE 16.0 Cleaning and care 16.1 In order to achieve a precise measurement result, it is very important to ensure that the infrared sensor of the device is clean and free from scratches. Therefore, check the sensor Fig. 24 prior to each measurement and / or when the “Cleaning” warning indicator (see Chapter 17.0, page 37) flashes and, if required, clean it carefully using a cotton bud (see Fig.
“CLEANING” WARNING INDICATOR USA 17.0 “Cleaning” warning indicator The device is equipped with a special warning indicator reminding the user to clean the infrared sensor on the measuring tip of the device. If you have not used the device for a longer period of time and / or after Fig. 26 approx. 5 - 6 measurements, the CL warning (“Cleaning” warning indicator) appears top left of the display and the green backlighting of the device flashes for approx. 30 seconds at intervals of 1 second (see Fig.
USA D CALIBRATION 18.0 Calibration The Ear and Forehead Thermometer DSO 364 was calibrated at the factory after manufacture had been completed. If the device is used according to the provisions and information provided in this instruction manual for private and non-commercial usage, it is not necessary to calibrate the device at specified time intervals. However, if you doubt the accuracy of the measured values, you should contact your dealer immediately.
MALFUNCTIONS USA 19.0 Malfunctions Malfunction The batteries have been inserted, but no information is shown on the display. Cause Solution There might be foreign particles in the battery compartment. Remove the foreign particles from the battery compartment. The batteries are empty (used) or have not been inserted with the correct polarity. Replace the empty batteries by full batteries. Observe the correct polarity. The battery con- Check the battacts do not fit tery contacts. closely.
MALFUNCTIONS USA D 19.0 Malfunctions Malfunction The temperature measurement is inaccurate and / or there are doubts regarding the measurement result. Cause Solution Operating temperature exceeds the valid range. Please comply with the operating conditions (see page 42). Check if the infrared sensor is dirty. Clean the infrared sensor (see page 36). Check if the device is used according to the instructions.
TECHNICAL SPECIFICATION USA 20.0 Technical specification Model / type: Dimensions: (L x W x T) Weight: Material: Power supply: Measurement: Method: Duration: Distance: Display: DSO 364 approx. 136.5 x 44.5 x 40.5 mm approx. 53.5 g (without batteries and table stand) Plastics, metals 3.0 V DC, 2 x AAA batteries (V = volt, DC = direct current) Contactless infrared measurement approx. 2 seconds approx.
USA D TECHNICAL SPECIFICATION 20.0 Technical specification Body temperature: Measurement range: Measurement accuracy: Object temperature: Measurement range: 89.6 °F - 109.3 °F (32.0 °C - 42.9 °C) from 95.9 °F - 107.6 °F: (35.5 °C to 42.0 °C) +/-0.4 °F (+/-0.2 °C) Other ranges: +/-0.5 °F (+/-0.3 °C) 68.0 °F - 140.0 °F (20.0 °C - 60.0 °C) +/-2.0 °F (+/-1.0 °C) Measurement accuracy: Ambient temperature: Measurement range: 41.0 °F - 139.8 °F (5.0 °C - 59.9 °C) Measurement accuracy: +/-2.0 °F (+/-1.
TECHNICAL SPECIFICATION USA 20.0 Technical specification 1060 hPa 700 hPa 2014-06 Type plate of the device: Atmospheric pressure: 700 hPa - 1060 hPa Use and store the device in a dry place Lot designation: V5214DSO364 Serial number: 00001 (consecutive number) Date of manufacture: 2014-06 (year, month) Manufactured for: Handelshaus Dittmann GmbH, Kissinger Straße 68, D-97727 Fuchsstadt / Germany Protection against electric shock according to type BF (body floating).
USA D WARRANTY 21.0 Warranty Handelshaus Dittmann GmbH warrants this product to be free from defects in material and workmanship for a period of ninety (90) days from the date of purchase. Should this product prove to be defective at any time during the warranty period, Handelshaus Dittmann GmbH will, at its option, either replace or repair it without charge. After the warranty period, a service charge will be applied for replacement of parts or labor for repair.