User's Manual

Chapter 1 Hardware
1-22
1-8 Memory Backup Period (Battery for
backup)
XIT-100-BW has two drive areas to store the file: F drive (Non-volatile) and S drive (Volatile). The application
data download from host computer is stored in F drive, so the data won't be lost even if the battery pack has
worn out. (Refer "2-1-1 Data Storage" "Information about the data storage (drive configuration)" See P.2-2).
■Memory Back Up by battery pack
Battery
Battery pack
Use
The operation by XIT-100-BW
Charging time
Charging the battery by using a Dedicated charger, Approximately 2.5
hours to complete charging.
Backup Period
The data storage period with a full charged battery pack attached is as fol-
lows.
The data in S drive and resume (suspended) information
Approximately 25 days
Notes in Use
When the battery pack is removed during operation, the data in the S drive
and resume information will be lost. When temporary storage is per-
formed, be sure to press the
key to power off, and then remove the bat-
tery pack. Refer to "1-10 Resume function"(P.1-25) for resume function.
If such an operation as removing a battery pack each time the terminal is
not used (the memory back up by the back up battery is applied), the
backup period will get extremely shortened in approximately half a year.
In this case, the replacement of the backup battery is necessary (paid)
therefore please attach the battery pack except for changing the battery.