System Software Specifications
Minimum System Requirements
Windows
®
2000 (32-bit) with SP4 or higher, or Windows XP
(32-bit) with SP1 or higher, or Windows Vista (32-bit) Home
Premium, Business or Enterprise, or Windows 7 (32-bit) Home
Premiuim or Professional, or Windows 2003 Server
300 MHz Pentium processor or faster
256 MB RAM
40 GB hard drive
Mouse and keyboard
CD-ROM drive
Printer with 300 dpi resolution
USB 1.1 or 2.0—2 USB ports
CD writer or equivalent for data backup
1024 x 768 screen resolution
Ordering Information
Kits and Systems
100710* PCH-100 Office Holter Software Kit
Includes software, 1 HR-100 Holter recorder,
and 7-lead patient cable
100711* PCH-100 Office Holter System
Includes laptop with 15” display, laser printer, Holter software,
1 HR-100 Holter recorder, and 7-lead patient cable
100712* PCH-200 Expert Holter Software Kit
Includes software, 1 HR-300 Holter recorder,
and 7-lead patient cable
100713* PCH-200 Expert Holter System
Includes laptop with 15” display, laser printer, Holter software,
1 HR-300 Holter recorder, and 7-lead patient cable
*Note: The above models include:
USB Bluetooth Adapter
USB SD Card Reader
Software
101510 PCH-100 Standalone Holter Software without Recorder
101511 PCH-100 LAN—3-user Holter Software without Recorder
101512 PCH-200 Standalone Holter Software without Recorder
101513 PCH-200 LAN—3-user Holter Software without Recorder
Accessories
401700 HR-100 Holter Recorder with 5-lead cable
401701 HR-100 Holter Recorder with 7-lead cable
401704 HR-300 Holter Recorder with 7-lead cable
704545 5-lead Patient Cable, AHA, HR-100
704547 7-lead Patient Cable, AHA, HR-100
704549 7-lead Patient Cable, AHA, HR-300
704553 HR-100 Carrying Case
704554 HR-300 Carrying Case
08113-0002 3-channel Holter Hookup Kit
45002-0000 Holter Electrodes, 500/case
Holter Recorder Characteristics
HR-100 HR-300
Length 3.8 in (96.5 mm) 4.4 in (112 mm)
Width 2.2 in (56 mm) 3.1 in (78 mm)
Height 0.7 in (18 mm) 1.4 in (36 mm)
Weight* 7 oz (198 g) 14 oz (397 g)
Keyboard Elastomer keypad with navigational
(HR 300 only) and soft menu keys.
*with battery (or batteries) and patient cable
Operation
HR-100 HR-300
Power Source one size AA two size AA
(size LR6) (size LR6)
alkaline battery alkaline batteries
Sampling Rate 200 sps 200, 500, 1,000 sps
Recording Period Maximum 24-48 hours continuous
Storage Capacity Up to 16 GB (SD card)
Storage Period Data remains valid for >5 years or until
memory card is initialized
Battery Life 48 hours
Pacemaker Detection ANSI/AAMI EC38-1998
Effective A/D Resolution 2.5 µV .5 mV
Dynamic Range +/- 300 mV +/- 300 mV
Frequency Response 0.05 to 100 Hz 0.05 to 250 Hz
Environmental Specifications
Operating Temperature 32 °F to 113 °F (0 °C to 45 °C)
Storage Temperature -10 °F to 149 °F (-23 °C to +65 °C)
Operating Humidity 10 to 95% noncondensing
Storage Humidity 5 to 95% noncondensing
Operating Altitude 700 to 1060 millibars
Storage Altitude 700 to 1060 millibars
Operating Shock 3 in (75 mm) drop to hard surface on any axis
Storage Shock 31.5 in (0.8 m) drop to hard surface on any axis
Operating Vibration 0.0002 G2/Hz from 5 to 350 Hz, ramping
to 0.0001 G2/Hz from 350 to 500 Hz, random
vibration spectrum, 10 minutes in each of
three orthogonal axes
Protection against ingress of water
IPX0—no protection against water
Device Classification
Meets or exceeds Council Directive 93/42/EEC, MDD, Class IIb
AECG, Device Type Type 1
EMC Class 2B
Conforms to Regulatory Standards
International Electro- CAN/CSA C22.2 No. 601.1-M90
Technical Commission UL 60601-1, IEC 60601-1-4, IEC 60601-1-1,
IEC 60601-1-2, IEC 60601-2-47
American Advancement of ANSI/AAMI EC38-1998
Medical Instrumentation
Australian Safety AZ/NZS 3200-1-0
Compatibility
CPT Codes
CPT Coding Options for Holter Monitoring
93230 Electrocardiographic monitoring for 24 hours by
continuous original ECG waveform recording
and storage without superimposition scanning
utilizing a device capable of producing a full
miniaturized printout; includes recording,
microprocessor-based analysis with report,
physician review and interpretation
93231 Recording (includes hook-up, recording,
and disconnection)
93232 Microprocessor-based analysis with report
93233 Physician review and interpretation
Welch Allyn Holter Systems
Specifications
A word about the coding information contained in this brochure.
Listed within this brochure are references to codes from the Current Procedural Terminology, Fourth Edition (CPT
®
).
Please note that the coding information contained here is neither conclusive nor does it ensure that you will be suc-
cessful in obtaining coverage and/or reimbursement from government and private payers.
Depending on circumstances that will vary from patient encounter to patient encounter, separate reimbursement
may or may not be allowed for use of a Welch Allyn product used during a specific procedure or service. Use of the
product may be included in the reimbursement for Evaluation and Management services provided by the physician.
Please check with the specific payer to confirm whether or not the use of a separate code is acceptable. Welch Allyn
does not assume any responsibility for the decisions made by payers regarding payment for procedures involving our
devices when the coding information suggested in this brochure is used.
Please refer to this page for a full listing of the codes and their accompanying descriptors before determining if the
code is suitable for submission on a claim to a payer.
® CPT is a registered trademark of the American Medical Association. All Current Procedural Terminology (CPT) five-
digit numeric codes, descriptions, numeric modifiers, instructions, guidelines, and other material are Copyright 2005
American Medical Association. All rights reserved.
Helping you improve patient care.
Welch Allyn
Holter Systems

Summary of content (6 pages)