Word Length Data Bits
This programming selection allows you to set the   at seven or eight
bits of data per character. If an application requires only ASCII Hex characters
0 through 7F decimal (text, digits, and punctuation), select 7 data bits. For
applications requiring use of the full ASCII set, select 8 data bits per character.
Default = seven data bits.
Parity
This programming selection provides a means of checking character bit
patterns for validity. The decoder can be configured to operate under Even,
Odd, MarkĂ/ĂNone, or Space parity options. The host terminal must be set up
for the same parity as the decoder, to ensure reliable communication.
Default = Even parity.
Word Length Stop Bits
This programming selection allows you to set the   at one or two
stop bits. Default = one stop bit.
 RSĆ232D Function Code Transmit programming may be found in General