User Manual
22
GB
Menu navigation
ZERO SMOG
VER BL.FW
SPEED 100 %
MANUAL / AUTOMATIC
FILTER TIME 0
CURRENT HOURS
FILTER TIME OFF
DEFAULT
OFF MODE
5 sec
5 sec
Display after power-on
BL = bootloader version
FW = rmware version
OFF MODE
The turbine and the backlit display
are off.To activate/deactivate, press
the UP/DOWN keys simultaneously.
Zero Smog 4V / 6V
The speed (30-100%) can be
entered using the UP/DOWN
keys.
Zero Smog 20T
The controlled vacuum (60%-
100% = approx. 6000-10000
Pa) is entered using the UP/
DOWN buttons.
Displays lter time (lter operating
hours) elapsed since last Reset.
5 sec
Species the xed nominal l-
ter life/nominal lter operating
hours
Adjustable from one hour to 999 days
Default setting as-delivered 200 days
After this time expires, the unit
switches to „red“
and an audible signal also sounds
Default opera-
ting mode
Filter time display
Specied lter time
Submenu functions
To select a menu item,
press the Menu key. Each
time the.
Menu key is pressed, the
next menu item is selected.
The display automatically
returns to the default
operating mode after ve
seconds.
FILTER TIME NO
RESET
VACUUM 60 %
Zero Smog
4V / 6V
Zero Smog
20T