User manual

Page 10 of 14
PROGRAM 1
E X I T L O A D S A V E
The program memories 1 - 10 can be selected using the UP/DOWN Control Keys (2)/(3).
The preferred program can be selected by pressing the LOAD Control Key (6).
The indication on the display changes to the automatic mode and displays the selected parameters.
If a temperature-profile has been prepared, it can be saved in the selected program memory by
pressing the SAVE Control Key (5).
The menu can be exited without saving any changes using the EXIT Control Key (7).
3. External Sensor
When using an external sensor (Thermocouple Type K), two different operating modes are
available. By pressing the Control Key "TIME" / "PREHEAT" (5) when switching on the unit (4), you
can toggle between the operating modes "MEASURE MODE" and "CONTROL MODE". The
following appears briefly in the display (1):
THERMOCOUPLE or THERMOCOUPLE
MEASURE MODE CONTROL MODE
Both operating modes only become active once the external sensor (14) has been connected.
3.1 External Sensor with measuring function "MEASURE MODE" (factory setting)
In this operating mode, the external sensor only has a measuring function. The temperature of the
external sensor is shown in the display (1). The Hot Air Tool temperature control regulates the
setpoint value for the nozzle temperature.
External sensor active in "MEASURE MODE"
UP
PRESS AT
THE SAME
TIME
DOWN
TEMP AIR PREHEAT
250 °C 25 l OFF