User manual

15
Read these instructions and the
accompanying safety information
carefully before starting up the
device and starting work with the device.
Keep these instructions in a place that is accessible to all
users.
Safety information
Thisappliancecanbeusedby
childrenagedfrom8yearsand
above and persons with reduced
physical,sensoryormentalcapa-
bilitiesorlackofexperienceand
knowledgeiftheyhavebeengiven
supervision or instruction concer-
ning use of the appliance in a safe
wayandunderstandthehazardsin-
volved.Childrenshallnotplaywith
the appliance.
Cleaningandusermaintenance
shallnotbemadebychildrenwit-
hout supervision.
WARNING
Electrical shock
If the device is faulty, active electrical conduc-
tors may be bare or the PE conductor may not be
functional.
RepairsmustalwaysbereferredtoaWeller-trained
specialist.
‚Iftheelectricaltool‘‘spowersupplycordisdamaged,this
mustbereplacedwithaspeciallyprefabricatedpower
supplycordavailablethroughthecustomerservice
organisation.‘
WARNING
Danger of injury
Thedeviceorpartsofthedevicemayfalloffduring
transportation.
WARNING
Danger of asphyxiation, Danger of
poisoning
Improper installation can result in above-normal
workplace concentrations
Measure the workplace concentration upon completion
of installation work
Inappropriate maintenance cycles for gas media
may result in above-normal workplace concentra-
tions
Specifymaintenancecycle
Above-normal contamination levels in the ambient
air during cleaning work on the pipe system/extrac-
tion area
Ifsuctioncapacityisimpairedbybuild-upwithinthe
pipesystem,replacethecontaminatedparts
A saturated activated carbon lter will not be able
to capture harmful substances. The harmful subs-
tances will be released back into the environment
unltered.
Observetherecommendedlterreplacement
intervals.
High concentrations of harmful gases can lead to
overheating of the activated carbon and possibly
trigger spontaneous combustion of the lter.
Run the unit on clean air for several minutes before
switching off.
Specied Conditions Of Use
Thisltrationsystemissuitablefortheextractionand
ltrationofparticlesandgases,dependingonthelter
medium used.
Thisdevicemayonlybeusedatroomtemperature
and indoors.
Theunitisdesignedforuseasasurfaceextraction
unitandisnotsuitableforextractingfumesdirectly
from the soldering gun.
Soldering or welding enamelled wire
Forsolderingandweldingenamelledwire,usethe
standardprelterF7.
Extractionofadhesivevapours
Useabroadbandgaslter(withoutasuspended
matterlter)fortheextractionofadhesivevapours.
WARNING
Danger of asphyxiation, Danger of
poisoning
Improperusemayresultinrespiratoryproblems,
asphyxiation,poisoningorcancer
Particlesandgaseswhichareunsuitableforthelter
mediuminusemaynotbeextracted.
Liquidsandammablegasesmaynotbeextracted
Neverusethedevicewithoutalterorwithafulllter.
Never use the device without the fan cover
GB
ENGLISH