Datasheet
13
Menu 2
Pressing and holding the Menu button (three seconds) takes you to menu 2
Fixed temperatures
Activation of the two xed temperatures which can be individually adjusted.
Option Description
ON Fixed temperatures Activated
OFF Fixed temperatures Deactivated (factory setting)
If the xed temperatures are activated, they can be selected and changed by pressing the UP and
DOWN buttons.
Backlighting
Option Description
0-100% LCD-Brightness (factory setting 80%)
Floating switching output
Selection of Zero-Smog output or robot output
Option Description
ES FE Zero-Smog output activated (factory setting)
ES rob Robot output activated
Sensitivity
Option Description
1
Non-Sensitive – Reacts to heavy (long) movement
2
3 Standard (factory setting)
4
5 Sensitive - Reacts to light (short) movement
GB
ENGLISH
1
3
2
5
4