Datasheet

13
Menu 2
Pressing and holding the Menu button (three seconds) takes you to menu 2
Fixed temperatures
Activation of the two xed temperatures which can be individually adjusted.
Option Description
ON Fixed temperatures Activated
OFF Fixed temperatures Deactivated (factory setting)
If the xed temperatures are activated, they can be selected and changed by pressing the UP and
DOWN buttons.
Backlighting
Option Description
0-100% LCD-Brightness (factory setting 80%)
Floating switching output
Selection of Zero-Smog output or robot output
Option Description
ES FE Zero-Smog output activated (factory setting)
ES rob Robot output activated
Sensitivity
Option Description
1
Non-Sensitive – Reacts to heavy (long) movement
2
3 Standard (factory setting)
4
5 Sensitive - Reacts to light (short) movement