Specifications

INSTALLATION (continued)
5
NOTE: This equipment must
be installed to comply with
applicable federal, state and
local plumbing codes and
ordinances.
CAUTION:
SHOCK HAZARD
Dispenser must be properly
grounded to prevent possible
shock hazard. DO NOT
assume a plumbing line
will provide such a ground.
Electrical shock will cause death
or serious injury.
IMPORTANT:
Supply power must match
nameplate for voltage and
phase. Connecting to the
wrong voltage will damage the
appliance or result in decreased
performance. Such damage is
not covered by warranty.
IMPORTANT: Do not connect
dispenser to electrical power
until you are ready to ll the
tank.
IMPORTANT: The ground
prong of the plug is part of a
system designed to protect
you from electrical shock in
the event of internal damage.
Never cut off the ground prong
nor twist a blade to t an
existing receptacle. Contact a
licensed electrician to install the
proper circuit and receptacle.
NSF requires that the unit be able to be moved for cleaning
underneath. A ex line or loops of copper tubing will satisfy this
requirement. See Figure 2 below.
In some areas, local codes require a backow preventer (check
valve) to be installed on the inlet water line. If a backow
preventer is used, you must install a water hammer arrester in the
incoming line, between the backow preventer and the brewer
inlet, as far away from the brewer as space will allow. This will
relieve the excessive back pressures that can cause faucet leaks
and solenoid malfunctions.
ELECTRICIAN’S INSTALLATION INSTRUCTIONS
REFER TO ELECTRICAL SPECIFICATIONS - Page 1
Check the nameplate to determine correct electrical service
required for the dispenser to be installed.
IMPORTANT: Before connecting to electricity, make sure
dispenser is connected to the water supply.
Model 1222 is equipped with a cord and plug. It requires a
115 - 125 volt 20 amp circuit (50/60 Hz, 2 wire plus ground, with
NEMA 5-15R).
Model 1222CA is equipped with a cord and plug. It requires a
115 - 125 volt 15 amp circuit (50/60 Hz, 2 wire plus ground, with
NEMA 5-15R).
CAUTION: EQUIPMENT DAMAGE
DO NOT connect Model 1225 to a circuit with voltage
higher than 208V. Equipment damage will result.
Such damage is NOT covered by warranty.
Model 1225: is equipped with a cord and plug. It requires
a 208V, 30 amp circuit (50/60 Hz, 2 wire plus
ground, with NEMA 6-30R).
Model 1226: is equipped with a cord and plug. It requires
a 240V, 30 amp circuit (50/60 Hz, 2 wire plus
ground, with NEMA 6-30R).
IL2351
COPPER LOOPS OR
FLEX LINES
(PROVIDED BY
PLUMBER)
SOLENOID
STRAINER
WASHER
FLOW
WATER
SUPPLY
WATER INLET
FITTING
SHUT-OFF VALVE
(PROVIDED BY
PLUMBER)
Fig. 2 Water Supply Installation
712 p/n 2M-76580 1222_1225_1226 Owmers Manual
712 p/n 2M-76580 1222_1225_1226 Owmers Manual