Owner`s manual
6
C. EQUIPMENT SET-UP
1. CURB or COUNTER MOUNTING
a. Setup the appliance only on a firm, level, non-combustable surface. Verify local codes for
requirements. Concrete, tile, terrazzo or metal surfaces are recommended. Metal over
combustible material may not meet code for non-combustible surfaces.
b. Appliance is approved for installation with zero clearance at bottom.
c. Recommend at least 3” clearance on sides and back to allow adequate air flow.
2. INSTALLING OPTIONAL CASTERS
a. Install casters, one on each corner of the appliance, in the holes provided. Locking casters
must be installed on the FRONT of the appliance.
b. Set up the appliance only on a firm, level, non-combustable surface. Verify local codes for
requirements. Concrete, tile, terrazzo or metal surfaces are recommended. Metal over
combustible material may not meet code for non-combustible surfaces.
c. LEVELING: Verify that the appliance sits firmly on all four casters when in its normal
operational position. With a spirit level, check that the appliance is level front-to-back and
side-to-side.
3. INSTALLING OPTIONAL LEGS (NOTE: Legs are not provided and must be purchased seprately.)
a. Install adjustable legs, one on each corner of the appliance, in the holes provided.
b. Set up the appliance only on a firm, level, non-combustable surface. Verify local codes for
requirements. Concrete, tile, terrazzo or metal surfaces are recommended. Metal over
combustible material may not meet code for non-combustible surfaces.
c. LEVELING: Verify that the appliance sits firmly ON ALL FOUR LEGS. With a spirit
level, check that the appliance is level front-to-back and side-to-side.
4. INSTALLING ON FABRICATED MOUNTING
a. Mounting must be capable of safely supporting 350 pounds (165 Kg.), and must be
fabricated to the following dimensions:
b. Attach the appliance securely to the mounting with four 3/4”-10 x 1” bolts.
1 (25mm) dia.
4 places
”
”
2
0-1/8
(
511mm)
”
25-15/16 (659mm)
FRONT