Installation Instructions For Converting an M4200 From I to 3 Phase
4. With step 3 completed, remove the existing plug and strip the black cord jacket back to
expose the red wire approximately 2". Slide the 90° adaptor (P/N 44256) over the cord.
Be sure that all four wires are of the same length and strip the wire insulation back
1/2". Now connect the plug (P/N 43924) to the four wires. Be sure to place the green
wire into the green lug of the plug. The remaining wires have no designated location.
Now mate the 90° adaptor with the plug.
5. With step 4 completed, take the new nameplate (P/N 44642 for 208V and P/N
44643 for 240V) and adhere it in place to the right of the cord over the
existing nameplate.
Note: Be sure to clean the surface before mounting. Failure to clean away
any grease or film will cause the nameplate to fall off or not stick
at all.
6. A receptacle (P/N 43874) has been provided for your convenience. This should be
mounted by an authorized electrician only.
7. With all steps completed, the side panel can now be put back in place. This may
be done by reversing step 2 as it applies.
If additional help is required, please call Wells Manufacturing Company Customer Service at
(702) 345-0444.