Operating instructions
SERVICING INSTRUCTIONS 
REPLACE ELEMENT 
Fig. 4 
Element Assembly 
Unplug fryer and allow to cool before servicing. 
A.  REMOVE ELEMENT HEAD FROM FRYER 
  1.  Remove two screws holding either element head pivot. 
 Remove pivot. 
  2.  Lift element head assembly from fryer. 
  3.  Remove bottom cover from control box. 
B. DISCONNECT ELEMENT 
  1.  Remove the handle and clamps from the element. 
  2.  Disconnect the wiring from the element terminals. 
  3.  Note position of each thermobulb and the routing of the 
    capillary tubes. Remove bulbs from element by removing two 
    bulb clips and three capillary clips from each bulb. 
  4.  Undo both holding nuts from terminal end of the element. 
  5.  Withdraw the element from the control box. 
C.  INSTALL NEW ELEMENT 
  1.  Wipe area around element openings in control box to remove 
    any grease or other cooking debris. 
  2.  Slide one fiber washer over each end of the new element. 
  3.  Insert element into the control box. Slide a lock washer over 
    each element , then thread on the holding nuts. Make sure the 
    element is square with the control box. Tighten holding nuts. 
  4.  Reconnect wiring to the element terminals. 
  5.  Reinstall the thermobulbs. Be sure the wire ring is intact and in 
    place at each end of the thermobulb. Snap a bulb clip over the 
    element and over each end of bulb to secure the bulb to the 
    element. The wire rings must be between the bulb clips. 
    Carefully route the capillary tube and secure with three   
    capillary clips. Repeat for both bulbs. 
  6.  Reinstall handle and clamps. 
D.  REINSTALL ELEMENT HEAD ON FRYER 
  1.  Be sure the pivot washer is in place on the pivot brackets. 
    While holding the support rod in the forward position, slide the 
    element head assembly onto the pivot. Reinstall the pivot 
    removed In step A. 
Test fryer for proper operation and return to service. 
CAUTION: 
BURN HAZARD 
Allow fryer to cool before 
performing this service. 
CAUTION: 
SHOCK HAZARD 
Unplug fryer from electric 
power before servicing. 
IMPORTANT: 
DO NOT damage the 
capillary tubes. If the tubes 
are pinched or kinked, they 
are not repairable. 
Fig. 5 Element Attachment 
IMPORTANT: 
Be sure wire rings are in 
place on thermobulbs. Rings 
must be positioned between 
the bulb clips. Failure to 
properly position the rings will 
result in the immediate failure 
of the thermostat due to 
thermobulb damage. 
Fig. 6 Cross-Section View of 
Elements 
5 
305 504367 Service Manual - Countertop Fryer LLF-14 