Operating instructions

SERVICING INSTRUCTIONS
REPLACE ELEMENT
Fig. 4
Element Assembly
Unplug fryer and allow to cool before servicing.
A. REMOVE ELEMENT HEAD FROM FRYER
1. Remove two screws holding either element head pivot.
Remove pivot.
2. Lift element head assembly from fryer.
3. Remove bottom cover from control box.
B. DISCONNECT ELEMENT
1. Remove the handle and clamps from the element.
2. Disconnect the wiring from the element terminals.
3. Note position of each thermobulb and the routing of the
capillary tubes. Remove bulbs from element by removing two
bulb clips and three capillary clips from each bulb.
4. Undo both holding nuts from terminal end of the element.
5. Withdraw the element from the control box.
C. INSTALL NEW ELEMENT
1. Wipe area around element openings in control box to remove
any grease or other cooking debris.
2. Slide one fiber washer over each end of the new element.
3. Insert element into the control box. Slide a lock washer over
each element , then thread on the holding nuts. Make sure the
element is square with the control box. Tighten holding nuts.
4. Reconnect wiring to the element terminals.
5. Reinstall the thermobulbs. Be sure the wire ring is intact and in
place at each end of the thermobulb. Snap a bulb clip over the
element and over each end of bulb to secure the bulb to the
element. The wire rings must be between the bulb clips.
Carefully route the capillary tube and secure with three
capillary clips. Repeat for both bulbs.
6. Reinstall handle and clamps.
D. REINSTALL ELEMENT HEAD ON FRYER
1. Be sure the pivot washer is in place on the pivot brackets.
While holding the support rod in the forward position, slide the
element head assembly onto the pivot. Reinstall the pivot
removed In step A.
Test fryer for proper operation and return to service.
CAUTION:
BURN HAZARD
Allow fryer to cool before
performing this service.
CAUTION:
SHOCK HAZARD
Unplug fryer from electric
power before servicing.
IMPORTANT:
DO NOT damage the
capillary tubes. If the tubes
are pinched or kinked, they
are not repairable.
Fig. 5 Element Attachment
IMPORTANT:
Be sure wire rings are in
place on thermobulbs. Rings
must be positioned between
the bulb clips. Failure to
properly position the rings will
result in the immediate failure
of the thermostat due to
thermobulb damage.
Fig. 6 Cross-Section View of
Elements
5
305 504367 Service Manual - Countertop Fryer LLF-14