Operating instructions
SERVICING INSTRUCTIONS (continued) 
REPLACE TEMPERATURE CONTROL THERMOSTAT 
OR HI-LIMIT SAFETY THERMOSTAT 
Fig. 7 
Thermostat 
Installation 
Unplug fryer and allow to cool before servicing. 
A.  REMOVE ELEMENT HEAD FROM FRYER 
  1.  Remove two screws holding either element head pivot. 
 Remove pivot. 
  2.  Lift element head assembly from fryer. 
  3.  Remove bottom cover from control box. 
B. DISCONNECT THERMOSTAT 
  1.  Remove the control knob if replacing the temperature control 
 thermostat. 
  2.  Remove the two screws holding the thermostat to the control 
 box. 
  3.  Note the position of the wiring. Disconnect the wiring from the 
 thermostat terminals. 
  4.  Note position of the thermobulb and the routing of the capillary 
    tube. Remove the bulb from the element by removing two bulb 
    clips and three capillary clips. 
  5.  Undo the pass-thru fitting and withdraw the thermostat from the 
 control box. 
C.  INSTALL NEW THERMOSTAT 
  1.  Wipe area around pass-thru openings in control box to remove 
    any grease or other cooking debris. 
  2.  Undo nut and lock washer from pass-thru fitting of the new 
    element. Insert the bulb from the inside of the control box. 
  3.  Reconnect wiring to the thermostat terminals. Connect wiring 
    then attach the thermostat to the control box 
  4.  Reinstall the thermobulbs. Be sure the wire spacing rings are 
    intact and in place at each end of the thermobulb. Snap a bulb 
    clip over the element and over each end of bulb to secure the 
    bulb to the element. The wire spacing rings must be between 
    the bulb clips. Carefully route the capillary tube and secure 
 with three capillary clips. 
  5.  Carefully route capillary tube away from electrical terminals 
    inside of the control box. Tighten the pass-thru fitting then seal 
    the inside of the pass-thru fitting with hi-temp sealant. 
D. REINSTALL ELEMENT HEAD ON FRYER (see page 5) 
Test fryer for proper operation and return to service. 
6 
CAUTION: 
BURN HAZARD 
Allow fryer to cool before 
performing this service. 
CAUTION: 
SHOCK HAZARD 
Unplug fryer from electric 
power before servicing. 
IMPORTANT: 
DO NOT damage the 
capillary tubes. If the tubes 
are pinched or kinked, they 
are not repairable. 
Fig. 8 Capillary Tube Pass-
Thru Fitting 
IMPORTANT: 
Be sure wire rings are in 
place on thermobulbs. Rings 
must be positioned between 
the bulb clips. Failure to 
properly position the rings will 
result in the immediate failure 
of the thermostat due to 
thermobulb damage. 
Fig. 9 Thermobulb Installation 
305 504367 Service Manual - Countertop Fryer LLF-14 