Specifications

9
C. TEMPERATURE OFFSET MODE
1. A user preference offset mode is provided should the user feel the oven cooks too hot or too cold.
2. The OFFSET MODE can be used to offset the set / displayed temperature from the sensed
temperature by as much as ± 35ºF, in 5ºF increments:
a. Rotate the TIME controller until the time digits on the display read "00:00".
b. Rotate the TEMP control until the temp digits display between 400º and 500º.
c. Press and hold the START TIMER key for five seconds.
d. Turn either the TIME or TEMP control until the desired offset is displayed.
e. Press the ACTUAL TEMP key to exit.
D. CONVECTION OVEN CLEANING INSTRUCTIONS
CAUTION: Burn Hazard
Do not attempt to clean the oven until it has cooled to 150ºF or less
1. Turn OVEN POWER SWITCH to FAN and FAN SPEED SWITCH to HIGH. With the door held
open, allow the oven to cool. When the oven interior has cooled to 150ºF or less, turn the OVEN
POWER SWITCH to OFF.
2. Remove racks and rack suports. Remove fan baffle.
CAUTION: Cut Hazard
FAN BLADES ARE SHARP. Use care when cleaning and/or wiping.
3. Brush the fan wheel and wipe it with a moist cloth. Sponge out all loose particles.
4. Scrub entire interior of convection oven with a plastic scouring pad and non-abrasive
cleanser.
5. For baked-on food spills, sparingly use a conventional oven cleaner. Wipe the area with vinegar
solution to neutralize the oven cleaner.
6. Wipe down the entire interior using a clean cloth or sponge, with hot water and a mild detergent.
IMPORTANT: Always wipe or rub in the direction of the polish lines or grain of the metal.
7. Clean oven door glass. NEVER USE ABRASIVE SCRUB PADS on the door glass. Always read
and follow direction on the container when using commercial cleaners. Dry with soft clean cloth.
8. Clean oven racks and rack supports in a sink or dishwasher.
9. Reinstall the fan baffle, paying particular attention that the lip on the right side of the fan baffle is fully
seated in the slot in the edge of the oven cavity. Reinstall rack supports and racks.
10. Turn power switch to FAN and fan switch to LOW. Verify that fan runs smoothly and does not
contact fan baffle. Turn power switch to OFF. Reposition fan baffle if necessary.