Operating instructions
LOWER CONTROL PANEL
(Located behind the Door)
1. FILTER SWITCH: ON position energizes the FILTER PUMP when the POWER
SWITCH is in the FILTER position.
2. HIGH LIMIT SAFETY THERMOSTAT: Turns the HEATING ELEMENT OFF if the
cooking oil temperature exceeds 425º F, or if the HEATING ELEMENT is energized
without oil covering the top of the HEATING ELEMENT.
The HI-LIMIT SAFETY THERMOSTAT is reset by pushing the Red button after the
cooking oil has been allowed to cool.
3. TEMPERATURE CONTROL THERMOSTAT: Controls the temperature of the
cooking oil by energizing / de-energizing the HEATING ELEMENT.
Set the Pointer to the desired cooking temperature marked on the panel.
The HEAT LIGHT will be ON any time the HEATING ELEMENT is energized.
5
ºF
ON
OFF
250
275
300
325
350
375
1
2
3
FILTER
THERMOSTAT
HI-LIMIT
RESET
CAUTION
FRYER MUST BE OFF
BEFORE USING FILTER