Product manual

Wells WFPE-68KFC Pressure Fryer
Wells WFPE-68KFC Pressure Fryer 01/26/04 Page 7
10
Refrigerate
collector
gasket in
water
Remove o-ring from collector and clean with cold, damp
towel. Place o-ring in fresh water in refrigerator.
Clean collector at sink with HOT water ONLY.
11
Clean
frypot
Place large stockpot under frypot
Scrape crackling ring from frypot and discard.
Rinse frypot with hot water.
Scrub frypot behind heating element coils and
heater brackets with the teflon brush and hot
water, then rinse.
Wipe frypot with damp towel, then with dry
towel.
Remove stockpot.
12
Dry coils
and
brackets
Wrap dry towel around bristle end of brush and dry heating
element coils and brackets.
13
Replace
lid and
collector
o-rings
Remove spare lid and collector o-rings from refrigerator.
Dry o-rings thoroughly, then lubricate with liquid shortening.
Install lid o-ring on lid and collector o-ring on collector.
(The collector o-ring must be in place to prevent shortening
from leaking.)
14
Install
collector
Install collector in frypot. Press to seat against bottom of fryer.
Leave heat plate on top of fryer overnight.
15
Remove
and clean
condensate
tray
Slide condensate tray out of fryer. Use both handles to carry.
Pour contents into a container to let shortening solidify. Skim
off shortening and discard. Pour ONLY WATER down floor
drain.
Clean condensate tray. Spray at sink with hot water ONLY.
Dry condensate tray with a towel, then reinstall in fryer.