Specifications

FRYPOT ELECTRICAL COMPONENTS
A. Access
Remove LOWER FRONT PANEL then UPPER FRONT PANEL.
Note wiring connections to control panel, switches and indicators.
Disconnect wiring and set upper front panel aside.
Carefully remove insulation from around frypot electrical terminals.
B. Temperature Probe
Disconnect temperature probe connector. Work pins out of
connector with Molex™ tool.
Remove nut and o-ring (interior of frypot). Withdraw probe and
fitting from frypot.
Remove compression nut and ferrule, then remove probe from
fitting.
Reassemble in reverse order.
Be sure frypot surfaces are clean before reassembly.
Use a fresh fiber washer and o-ring.
Be sure connector pins are fully
seated in connector.
F. REPLACE HI-LIMIT THERMOSTAT
Disconnect wiring from old hi-limit
thermostat.
Remove old hi-limit probe from frypot.
Remove and discard old hi-limit
thermostat and bulkhead fitting.
Mount new hi-limit thermostat bracket
to cabinet. Be sure green ground
wire is attached to one of the bracket
screws.
WARNING
Electric Shock
Hazard
Disconnect from electrical
power before removing any
panel or cover.
CAUTION
BURN
HAZARD
Drain oil and allow fryer to
cool before proceeding
TOOLS REQUIRED:
#2 Phillips Screwdriver
Assorted open wrenches
from 3/8" to 15/16"
Molex™ connector tool
Container to hold fasteners
IMPORTANT:
Tighten fittings only enough
to prevent leaks.
Over tightening is not
necessary.
ASSEMBLY & TORQUE
SPECS:
Temperature Probe
25 ft.-lbs
Compression Nut
35 ft.-lbs
Hi-Limit Thermostat
25 ft.-lbs
Compression Nut
35 ft.-lbs
Element
Element Clamp
23 in.-lbs
Bulkhead Fitting
30 ft.-lbs
Terminal Nut, Inner
8 in.-lbs
Terminal Nut, Outer
30 in.-lbs
Terminal Locknut
30 in.-lbs
SERVICING INSTRUCTIONS (continued)