Specifications
SERVICING INSTRUCTIONS (continued)
SERVICE
30
These servicing instructions are intended for use by qualified technical personnel only.
These servicing instructions are intended for use by qualified technical personnel only.
WARNING
Electric Shock
Hazard
Disconnect from electrical
power before removing any
panel or cover.
CAUTION
BURN
HAZARD
Allow fryer to cool. Be sure all
pressure is relieved before
proceeding.
TOOLS REQUIRED:
7/16" Nut Driver
1" Open End Wrench
Container to hold
fasteners
Food-Grade Silicone Sealant
DEAD WEIGHT ASSEMBLY
A. Access
Remove RIGHT SIDE PANEL, LEFT SIDE PANEL and UPPER
REAR PANEL.
B. Pressure Relief Components
Unlatch DEAD WEIGHT COVER and lift off.
DEAD WEIGHT lifts straight out of the CAGE.
The GASKET may be lifted out of the BODY ASSEMBLY
C. Body Assembly
Remove PIVOT ARM and RELIEF PIN (see page 31).
Disconnect PRESSURE HOSE ASSEMBLY from BODY.
Be careful that the hose does nor twist or kink.
Remove four nuts holding body assembly to cabinet. Remove
body. Note that body may be attached with sealant to cabinet top.
Reassemble in reverse order.
When reinstalling relief pin, do not over tighten retaining plate
screws. Relief pin must be free to drop of its own weight.
Be sure to seal body to cabinet top with a thin bead of food-grade
silicone sealant.