SERVICING INSTRUCTIONS (continued)
SERVICE
POWER BOARD
Repair time not to exceed 1.0 hour (including calibration)
A. Preparation
1. Disconnect Water-Max™ from electrical power.
2. Shut off water supply to Water-Max™.
B. Removal
1. Remove front assembly (see page 28).
2. Note wiring connections. Disconnect wiring from board.
3. Remove 4 ea. 11/32” nuts from corners of power board.
Remove power board from unit.
C. Installation
1. Install new board. Note orientation. Mounting nuts should be snug,
but not over-tight.
2. Connect wires per drawing below. Be careful that inlet and outlet
water temperature thermocouples are properly connected.
3. Reinstall front cover assembly. Do not install support cover yet.
WARNING
Electric Shock
Hazard
Disconnect Water-Max™
from electrical power before
removing any panel or
cover.
CAUTION:
SHOCK HAZARD
Removal of the top, front or
side panels results in
Exposed electrical circuits.
Setting the temperature
must be performed by a
qualified technician only.
Use care whenever working
around exposed electrical
circuits.
TOOLS REQUIRED:
Digital Thermometer
#2 Phillips Screwdriver
Small flat-blade screwdriver
11/32” Nut Driver
Container to hold fasteners
Needle Nose Pliers
36