507 WELLS BLOOMFIELD, LLC 2 ERIK CIRCLE, P. O. Box 280 Verdi, NV 89439 telephone: 775-689-5707 fax: 775-689-5976 www.wellsbloomfield.com SUPPLEMENTAL SERVICE INSTRUCTIONS WV-FG WV-FGRW and WV-FGRWT ELECTRIC FRYER/GRIDDLE with VENTLESS HOOD SYSTEM IMPORTANT: WELLS BLOOMFIELD, LLC PROPRIETARY INFORMATION. DISSEMINATION OF THIS INFORMATION TO ANYONE OTHER THAN WELLS AUTHORIZED SERVICE AGENTS IS STRICTLY PROHIBITED.
PRECAUTIONS AND GENERAL INFORMATION GENERAL WARNING: RISK OF INJURY Installation procedures must be performed by a qualified technician with full knowledge of all applicable electrical and plumbing codes. Failure can result in personal injury and property damage. WARNING: ELECTRIC SHOCK HAZARD All servicing requiring access to non-insulated electrical components must be performed by a qualified technician. Some procedures involve exposed live circuits.
TABLE OF CONTENTS GENERAL GENERAL Precautions & General Information …………….………… xi Specifications ..……………………………...................….. 1 Features & Operating Controls ……………………………. 2 VENTILATOR HOOD SECTION Filter Arrangement .......................................................... 8 Service Indicator Lights .…….......................................… 9 Operational Notes ........................................................... 10 Filter System ............................................................
FEATURES & OPERATING CONTROLS GENERAL 28 VENTILATOR CONTROL PANEL see pages 4 & 5 1 VENTILATOR POWER ON CHECK FILTERS REPLACE PREFILTER 56 SERVICE REQUIRED REPLACE FILTER PACK VCS 2000 53 a15 VENTLESS COOKING SYSTEM 19 5 16 18 16 18 57 a11 22 22 COOKING CONTROLS see pages 4 thru 7 58 58 a10 ANSUL 40 12 IN CASE OF FIRE ® PULL HANDLE 41 TO ACTIVATE FIRE SUPPRESSION SYSTEM 44 a6 COCKED FIRED a31 43 OPTIONAL DRAWER WARMERS see page 6 & 7 8 9 2 38 SV507 SvcManual WV-FG(RW)) F
FEATURES & OPERATING CONTROLS (continued) ITEM DESCRIPTION COMMENT 1. NAMEPLATE Gives manufacturer, make and model description. Also lists voltage and amperage data. 5. APPLIANCE LIGHT ON when hood power switch is ON. Illuminates cooktop. FIRE SUPPRESSION AGENT TANK (1.5 gal.) Container for Ansulex™ Low-pH liquid fire suppression liquid. 8. ADJUSTABLE (FRONT) LEG Allows the unit to be leveled. 9.
FEATURES & OPERATING CONTROLS (continued) GENERAL VENTILATOR POWER ON REPLACE PREFILTER CHECK FILTERS SERVICE REQUIRED REPLACE FILTER PACK VCS 2000 VENTLESS COOKING SYSTEM V.01 V.02 V.03 V.04 V.05 V.06 Fig. 2 Ventilator Section Controls & Indicator Lights F.03 ELEMENT HEAD (SHOWN LOWERED) F.04 F.05 F.06 F.07 F.12 F.08 F.09 F.10 F.01 FRYER (ELEMENT HEAD SHOWN RAISED) F.02 Fig. 3 Griddle & Warmer Drawer Operating Features & Controls 4 SV507 SvcManual WV-FG(RW)) F.
FEATURES & OPERATING CONTROLS (continued) DESCRIPTION COMMENT VENTILATOR SECTION CONTROLS * V.01 POWER SWITCH Energizes BLOWER MOTOR. If, after 10 seconds, proper conditions are met, cooking appliances are energized. APPLIANCE LIGHT is ON when POWER SWITCH is ON. V.02 POWER ON INDICATOR GREEN. Glows when POWER switch is ON. V.03 CHECK FILTERS ALARM INDICATOR AMBER. Glows if one or more filters are out of position. Check all filters and baffles for proper installation. V.
FEATURES & OPERATING CONTROLS (continued) GRIDDLE SECTION G.05 G.06 G.07 G.01 FR YE R GENERAL G.04 G.02 G.03 Fig. 4 Griddle Operating Features 7 Controls HUMITROL RACK DRAWER INSERT PAN OPTIONAL DRAWER WARMER SECTION D.03 RW-STYLE D.01 D.04 D.06 RWT-STYLE D.05 Fig. 3 Drawer Warmer Operating Features & Controls 6 SV507 SvcManual WV-FG(RW)) D.
FEATURES & OPERATING CONTROLS (continued) DESCRIPTION COMMENT GRIDDLE SECTION G.01 GRIDDLE TEMPERATURE CONTROL Thermostatic control of griddle temperature G.02 GRIDDLE HEAT INDICATOR Glows when heating elements are energized. G.03 GREASE DRAWER Collects cooking waste from GRIDDLE. Removable for cleaning. G.04 COOKING SURFACE Heated portion for cooking food. G.05 SPLATTER SHIELD Helps control grease splatter and contamination between the GRIDDLE and FRYER sections. G.
HOOD OPERATION - FILTER ARRANGEMENT FAN WALL OF UNIT FILTER PA CK SE AL FILTER PACK FILTER PA CK AIR FLOW VENTILATOR HOOD FILTER PA CK PO SITIO N SWITCH HOL DE R CLIP GRE ASE B AFFLE PO SITIO N SWITCH H OLDER CLIP CLIPS ONTO LEDGE PRE -FILTER AS SEMB LY GRE ASE BA FFL E GRE ASE TROUGH PRE -FILTER NOTE: AIR FL OW A RRO W PO INTS AWAY FROM INSTAL LER WHEN PRO PERLY INSTA LLE D FILTER HOOK R E TE R FILTER HOOK FILTER RAIL FILTER HANDLE FILTER FRAME NOTE: P RE-FILTER IS S ENSE D AS B EING IN P
HOOD OPERATION - SERVICE INDICATOR LIGHTS POWER SWITCH SV507 SvcManual WV-FG(RW)) INDICATOR LIGHT When lit, indicates that electrical power is available, (GREEN) VENTILATOR and that the power switch (V.01) is turned ON. POWER ON INDICATOR LIGHT (AMBER) CHECK FILTERS (POSITION) When lit, indicates that the BAFFLE, PRE-FILTER and/or FILTER PACK is not in its proper position, or that an interlock switch is out of adjustment.
HOOD OPERATION - OPERATIONAL NOTES WARNING: FIRE AND HEALTH HAZARDS VENTILATOR HOOD DO NOT bypass or attempt to bypass the filter placement interlocks. Operating the appliance without filters properly in place will compromise the fire protection and air filtration capabilities of this unit. Serious personal injury and/or substantial property damage may result.
HOOD SECTION - OPERATIONAL NOTES (continued) FIRE DAMPER LABEL SHUTTER DAMPER SUPPORT FUSIBLE LINK 280ºF FIRE DAMPER INSTRUCTIONS 1. The FIRE DAMPER is accessible by removing the TOP PANEL The FIRE DAMPER sets in the DAMPER SUPPORT and may be removed by lifting straight up. SV507 SvcManual WV-FG(RW)) 2. The FIRE DAMPER normally needs no maintenance. If it becomes heavily contaminated with dust and/or grease, it must be replaced. 3.
HOOD SECTION - FILTER SYSTEM HOOD ASSEMBLY (LOOKING UP) VENTILATOR HOOD FILTER PACK POSITION MONITOR GREASE BAFFLE POSITION MONITOR PRE-FILTER ASSEMBLY NOTE AIR FLOW ARROWS ON GREASE BAFFLE, PRE-FILTER AND FILTER PACK. INSTALL THESE COMPONENTS SUCH THAT ARROWS POINT TOWARD FAN FILTER PACK GREASE BAFFLE 1. The GREASE BAFFLE separates grease particles and water vapor from the air stream by the centrifugal force of the air moving through its inter-leaved baffle plates.
HOOD SECTION - VACUUM SYSTEM FAN PORT A VS4 PORT A VS1 VENTILATOR HOOD PORT B FAN PORT C PORT C PORT C VS3 PORT B PLENUM PORT (AFTER FILTER PACK) VS2 SV507 SvcManual WV-FG(RW)) VS2 FILTER PACK ALERT Will illuminate "REPLACE FILTER PACK" indicator if pressure drop across the filter pack exceeds setting. VS3 PRE-FILTER ALERT Will illuminate "REPLACE PRE-FILTER" indicator if pressure drop across the prefilter exceeds setting.
HOOD SECTION - ANSUL® FIRE DETECTION SYSTEM HOOD ASSEMBLY VIEWED FROM REAR SERIES DETECTOR VENTILATOR HOOD FUSE LINK 212ºF FUSE LINK 212ºF IN ANS CA FIRSE O E F BLIND HOLE PU HA NLDL LE FIRTO E AC SU TIV P SY PR ATE ST ES EM SIO UL ® N MANUAL PULL STATION THREADED THRU HOLE CABLE SITS IN GROOVE IN PULLEY PULLEY ELBOW IMPORTANT: All servicing of the fire detection system to be performed by an authorized Ansul® agent only. 1.
HOOD SECTION - ANSUL® FIRE SUPPRESSION SYSTEM HOOD ASSEMBLY VIEWED FROM REAR FLEX HOSE NOZZLE 290 APPLY SEALANT TAPE PLENUM NOZZLE ASSY NOZZLE 1W SEAL WITH TEFLON TAPE INS ID E OU TS IDE FIBER WASHER IS ALWAYS ON THE INSIDE CABINET WALL SV507 SvcManual WV-FG(RW)) SEAL WITH TEFLON TAPE TYPICAL BULKHEAD FITTING FIRE SUPPRESSION MEDIA TANK PRESSURE CARTRIDGE 1. Actuation of the Ansul® system will cause the pressure cartridge seal to be punctured, which will pressurize the 1.5 gallon media tank.
HOOD SECTION - TROUBLESHOOTING SUGGESTIONS SYMPTOM VENTILATOR HOOD Entire unit inoperative No lights glow No buzzer sounds Cooking appliance inoperative “POWER” light on hood ON. Vent fan working ok with no service Cooking appliance inoperative “POWER” light on hood ON. Vent fan working OK.
HOOD SECTION - TROUBLESHOOTING SUGGESTIONS (continued) POSSIBLE CAUSE Prefilter is at end of service life Vent fan working OK, but amber “REPLACE PREFILTER” light ON. Vacuum Switch VS3 damaged “REPLACE PREFILTER” light turns on some of the time. “REPLACE FILTER PACK” light ON. Replace prefilter Replace vacuum switch VS3 Pre-filter frame not hooked in position at top Hook metal pre-filterframe at top to prevent air blowing around filter Pre-filter position switch SW1 misadjusted or damaged.
GRIDDLE SECTION - OPERATIONAL NOTES SPLASH GUARD EXTENSION GRIDDLE ASSEMBLY w/TROUGH THERMOSTAT LOWER CONTROL PANEL CONTROL KNOB GRIDDLE PART OF FRYER HEATING INDICATOR (AMBER) GREASE TRAY CAUTION: BURN HAZARD 2. The griddle has a single section. Control is via capillary and bulb thermostat with DPST switch. 3. The griddle is heated by two identical elements, wired in parallel. 4. Griddle is powered by the cooking appliance contactor.
GRIDDLE SECTION - ELEMENT CLAMPING DIAGRAM 53474 53474 52038 51968 52028 51968 53474 53474 51968 51968 51968 52038 52038 53474 GRIDDLE 52028 52038 53474 FRONT ELEMENT MOUNTING STUD LOCATION 50512 ELEM 240V 3000W TROUBLESHOOTING SUGGESTIONS SV507 SvcManual WV-FG(RW)) DESCRIPTION Griddle will not heat POSSIBLE PROBLEM SUGGESTED REMEDY Hood section not "ON" Verify that Hood Power Switch is "ON". If "SERVICE REQUIRED" indicator is lit, rectify filter problem.
FRYER SECTION - PERIODIC CLEANING CAUTION: PERIODIC CLEANING BURN HAZARD Add 1/2 cup of granulated dishwasher detergent to frypot. Fill with water to the MAX OIL line. Be sure frypot and elements are dry before returning unit to service. Water left in the frypot will boil off when heating, splattering hot oil. Lower the element into the frypot and set the control knob to 225ºF Boil the mixture for five minutes. Turn the control knob to OFF. Allow the mixture to set in the frypot overnight.
FRYER SECTION - DISPOSAL OF USED OIL DANGER: BURN HAZARD Contact with hot oil will cause severe burns. Allow the fryer to cool before cleaning. Always wear protective clothing and heat resistant gloves when handling hot oil. PREPARATION Turn temperature control to OFF Allow fryer to cool completely before draining FREQUENCY Daily, or as needed TOOLS Container for disposal of used oil. OIL DISPOSAL CAUTION: BURN HAZARD Allow fryer to cool completely before draining. CAUTION: 1.
FRYER SECTION - SERVICE INSTRUCTIONS 5/8-18 NUT LOCK WASHER FIBER WASHER CAUTION: BURN HAZARD CAPILLARY CLIP 6 places Allow fryer to cool before performing this service. ELEMENT BULB CLIP 4 places CAUTION: SHOCK HAZARD 2 places HI-LIMIT BULB (ref) Element Assembly Disconnect fryer from electric power before servicing. IMPORTANT: DO NOT damage the capillary tubes. If the tubes are pinched or kinked, they are not repairable.
REPLACE FRYER SPRING SECTION FOR-FRYHEAD SERVICE INSTRUCTIONS SUPPORT ROD HI-LIMIT THERMOSTAT CONTROL KNOB CAUTION: BURN HAZARD Allow fryer to cool before performing this service. Thermostat Installation TEMP CONTROL THERMOSTAT CAUTION: SHOCK HAZARD CAPILLARY CLIP 6 places Disconnect fryer from electric power before servicing. BULB CLIP 4 places TEMP CONTROL THERMOSTAT BULB IMPORTANT: Disconnect from electric power and allow fryer to cool before servicing. A.
FRYER SECTION - SERVICE INSTRUCTIONS CAUTION: BURN HAZARD Allow fryer to cool before performing this service. Support Rod Spring Installation CAUTION: SHOCK HAZARD Disconnect fryer from electric power before servicing. IMPORTANT: Disconnect from electric power and allow fryer to cool before servicing. A. REMOVE ELEMENT HEAD FROM FRYER Note: Some operations can be performed without removing the fryhead. However, doing so will ease access to components and fasteners. 1.
FRYER SECTION - TROUBLESHOOTING SUGGESTIONS DESCRIPTION POSSIBLE PROBLEM SUGGESTED REMEDY Unit not plugged in or circuit breaker tripped Plug into proper receptacle Reset circuit breaker Ventilator not running Press ventilator power switch ON Cooking appliance contactor not energized Refer to hood section to troubleshoot ventilator problems Fryer power switch not ON Press fryer heat switch ON Temperature control knob not set to desired temperature Set to desired temperature Hi-limit safety trip
DRAWER WARMER SECTION - OPERATIONAL NOTES OPTIONAL HUMITROL RACK DRAWER STOP PRODUCT PAN LATCH ASSEMBLY OPTIONAL DIAL THERMOMETER DRAWER ASSEMBLY THERMOSTAT CONTROL KNOB OPTIONAL ELECTRONIC CONTROL CONTROL MODULE POWER SWITCH ºF OR ºC INDICATORS LED READOUT CONTROL MODULE "PROCESS" KEY PROCESS LOAD INDICATOR INCREMENT AND DECREMENT KEYS CAUTION: BURN HAZARD DRAWER WARMER NOTE: In the absence of a drawer warmer appliance, the WVG-136 is equipped with a storage cabinet in the base.
DRAWER WARMER SECTION - CONTROL MODULE for RWT- STYLE UNITS CONTROL MODULE ITEM 1 2 3 DESCRIPTION 1 PROCESS Key: Press to view actual temperature of cavity. 2 4 Character LED Display: Normally shows SETPOINT temperature. 3 ºF or ºC Indicator: Glows to indicate if unit is configured for degrees Fahrenheit or degrees Celsius. 4 LOAD Indicator: Glows when heating element is energized.
DRAWER WARMER SECTION - TROUBLESHOOTING SUGGESTIONS SYMPTOM No lights or heat (both drawers) No heat (one drawer) POSSIBLE CAUSE SUGGESTED REMEDY Hood power switch not "ON" Press power switch to "ON" NOTE: Drawer warmer is energized any time hood power switch is "ON" and Ansul® system is ready. Hood need not be operating. Temperature control not set Set for desired temperature. Damaged thermostat or heating element (RW-style units) Inspect thermostat, heating element, wiring and connections.
EXPLODED VIEWS PARTS BREAKDOWN for ANSUL® COMPONENTS FOR USE ONLY BY AUTHORIZED ANSUL© SERVICE PERSONNEL Refer to Ansul© part no. 418078-05 R-102 Restaurant Fire Suppression System Design, Installation, Recharge and Maintenance ref. ADAPTER, QUICK-SEAL 3/8” ANSUL© p/n 77284 ref. NOZZLE 290 ANSUL© p/n 419342 (2 places) ref. NOZZLE 1W ANSUL© p/n 419336 FUSIBLE LINK 212ºF MODEL K 503037 ASSY, PULL STATION ANSUL© 501389 F TO IT UN ON FR ref.
EXPLODED VIEWS HOOD CABINET COMPONENTS INTERNAL BRACKETS FIRE DAMPER ASSY 280ºF (ref.
FITTING, 1/2” CONDUIT STRAIGHT 57748 ASSY, BLOWER 240V 502584 VACUUM SWITCH #4 502593 VACUUM SWITCH #1 502590 VACUUM SWITCH #3 502592 ASSY, VAC TUBE MANIFOLD 502588 VACUUM SWITCH #2 502591 ref Ansul® 77284 ref Ansul® 77284 SWITCH, POWER 8528-40 SWITCH, FILTER INTERLOCK 500407 (2 pl) BUZZER, 240V 64834 LIGHT, INDICATOR GREEN 240V 55697 LIGHT, INDICATOR AMBER 240V 50516 (3 pl) OD FR ON TO C LE L CA P - U I TR FH R PE LIGHT, INDICATOR RED 240V 51157 E OO D HO TERMINAL BLOCK 2P 250V
GRIDDLE PLATE & ELEMENTS EXPLODED VIEWS INSULATION PAD 57407 (pk 2'x4') CLIP, INSULATION 53474 (pk12) (6 ea) CLAMP, THERMO 52028 (4 ea) CLAMP, ELEM CENTER 51968 (5 ea) NUT, 1/4-20 HEX Ni 51253 (pk100) (36 ea) CLAMP, ELEM END 52038 (4 ea) HEATING ELEMENT 50512 (240V) (2ea) SV507 SvcManual WV-FG(RW)) NUT, 10-32 HEX 55313 (16 ea) T ON GRIDDLE SHOWN INVERTED (ref.
EXPLODED VIEWS GRIDDLE CABINET EXTENSION, GRIDDLE SPLASHGUARD 504415 SEALANT 1/4”x98” 53306 SHIELD, THERMO 51974 (2 reqd) THERMO, CONTROL 502825 SCREW, 6-32x3/16 51718 (pk10) KNOB 502826 SV507 SvcManual WV-FG(RW)) LIGHT, SIGNAL AMBER 50516 HANDLE 51973 SHROUD, GREASE DRAWER 51989 TRAY FRONT 53948 LIGHT, SIGNAL RED 51157 GREASE TRAY ASSY COMPLETE 50279 SWITCH 2P 50A 84098 33 PART OF FRYER SECTION
DRAWER WARMER SECTION 21488 55487 (pk 50) part of 50471 18-302 55565 55530 (pk 10) 67096 heavy-duty drawer assy complete 55487 (pk 50) 69251 50483 (pk 6) CLO SED OPE N 51796 64475 OPTIONAL THERMOMETER 52112 50471 (includes strike and catch) 18-302 (typ.
WIRING SCHEMATIC HOOD SECTION G L1 L2 L3 CAC-1 CAC-2 CAC-3 WIRING SERVICE REQUIRED INDICATOR PS1-1 FS1(NC) CHECK FILTER INDICATOR SW1 VS4 VS1 SW2 PS1-2 COIL TB1 JUMPER COOKING APPLIANCE CONTACTOR BLOWER MOTOR POWER ON INDICATOR VS3 REPLACE PREFILTER INDICATOR VS2 REPLACE FILTER PACK INDICATOR NC NC COIL DRAWER WARMER RELAY FS1(NO) ZZZ ANSUL® SYSTEM BUZZER TO BLDG FIRE ALARM SYSTEM TO DRAWER WARMER TO FRYER/GRIDDLE 36 WV-FG(RW) HOOD SECTION WIRING SCHEMATIC LEGEND CAC = COOKING APPLI
WIRING DIAGRAM HOOD SECTION VENTILATOR POWER SWITCH SERVICE REPLACE REPLACE PREFILTER FILTER PACK REQUIRED INDICATOR INDICATOR INDICATOR CHECK FILTER INDICATOR POWER ON INDICATOR 16 EXTERNAL CONTROL TERMINAL BLOCK 1 EXTERNAL SHUTDOWN CONTROL 13 JUMPER 2 3 21 22 6 10 14 15 BLACK WHITE HOOD LIGHT 7 12 9 VACUUM SWITCH VS4 (AIRFLOW) POWER CORD 4 35 24 RED ANSUL® SYSTEM BLOWER MOTOR GREASE BAFFLE POSITION SW 3 2 BLACK 23 19 C NO T1 T2 T3 C 4 17 NO 18 NO CONTACTOR 5 208/240V
WIRING SCHEMATIC COOKTOP SECTION FROM COOKING APPLIANCE CONTACTOR WIRING POWER SWITCH POWER LIGHT FRYER HEATING ELEMENT HI-LIMIT T'STAT T TROUBLE LIGHT T FRYER CONTROL T'STAT TEMP LIGHT FRYER GRIDDLE TEMP LIGHT T GRIDDLE CONTROL T'STAT GRIDDLE HEATING ELEMENTS 38 SV507 SvcManual WV-FG(RW)) WV-FG(RW) COOKTOP SECTION WIRING SCHEMATIC
WIRING DIAGRAM GRIDDLE HEATING ELEMENTS FRYER HEATING ELEMENT 65 TROUBLE LIGHT (RED) FRYER CONTROL THERMOSTAT 68 TEMP LIGHT (AMBER) 73 72 HI-LIMIT T'STAT POWER LIGHT (GREEN) 70 60 61 62 GRIDDLE SECTION 52 67 55 FRYER POWER SWITCH 64 GRIDDLE 63 CONTROL THERMOSTAT L1 L2 L3 56 69 TEMP LIGHT (AMBER) L1 L1 L2 L2 L3 L3 FROM COOKING APPLIANCE CONTACTOR 51 59 71 66 58 FRYER SECTION SV507 SvcManual WV-FG(RW)) WIRING DIAGRAM WV-FG from part no.
WIRING SCHEMATIC DRAWER WARMER SECTION (RW-STYLE) L1 L3 T3 T WIRING T4 T DRAWER WARMER ELEMENT (UPPER) HEATING INDICATOR DRAWER WARMER ELEMENT (LOWER) HEATING INDICATOR WV-FGRW DRAWER WARMER SECTION WIRING SCHEMATIC LEGEND T3, T4 = DRAWER WARMER THERMOSTAT DRAWER WARMER SECTION (RWT-STYLE) L1 L3 DRAWER WARMER ELEMENT (UPPER) E CONTROLLER E2 DRAWER WARMER ELEMENT (LOWER) E CONTROLLER WV-FGRWT DRAWER WARMER SECTION WIRING SCHEMATIC LEGEND E1, E2 = DRAWER WARMER TEMPERATURE CONTROLLER N.O.
WIRING DIAGRAM DRAWER WARMER SECTION (RW-STYLE) 1 INDICATOR LIGHT T 7 WIRE NUT LOWER HEATING ELEMENT 240VAC 900WATTS 8 8 2 3 4 T THERMOSTAT 7 WIRE NUT WIRE NUT 32 31 33 THERMOSTAT FROM DRAWER WARMER RELAY WIRING WIRE NUT UPPER HEATING ELEMENT 240VAC 900WATTS WIRING DIAGRAM RW-26 from p/n 300959 issue A INDICATOR LIGHT SV507 SvcManual WV-FG(RW)) DRAWER WARMER SECTION (RWT-STYLE) UPPER HEATING ELEMENT 240VAC 900WATTS UPPER HEATING ELEMENT 240VAC 900WATTS 4 4 7 TEMP PROBE 7 CONTROLL
MSDS - ANSULEX™ Low pH FIRE SUPPRESSION MEDIA DOCUMENTATION SV507 SvcManual WV-FG(RW)) 42
SV507 SvcManual WV-FG(RW)) DOCUMENTATION MSDS - ANSULEX™ Low pH FIRE SUPPRESSION MEDIA 43
SV507 SvcManual WV-FG(RW)) 44 WELLS BLOOMFIELD, LLC DOCUMENTATION
SV507 SvcManual WV-FG(RW)) WELLS BLOOMFIELD, LLC 45 Replace two (2) fire suppression links at cooking appliance: each link is rated @ 212ºF Replace fire damper fusible link: rated @ 280ºF Max interval: 12 months DOCUMENTATION