Specifications

FEATURES & OPERATING CONTROLS (continued)
3
VENTILATOR SECTION
ITEM DESCRIPTION COMMENT
1 NAMEPLATE
Gives Manufacturer, Model and Serial Number information.
Also lists electrical specications.
a6.
FIRE SUPPRESSION
AGENT TANK (1.5 gal.)
Container for Ansulex™ Low-pH liquid re suppression liquid.
8 ADJUSTABLE (FRONT) LEG Allows the unit to be leveled.
9 RIGID (REAR) CASTER
Allows the unit to be easily positioned by lifting the front of the unit
slightly.
a10. MANUAL PULL STATION
Provides a means of manual activation of the re suppression
system. PULL ONLY IN CASE OF FIRE!
a11. FUSIBLE LINKS
Automatically activates re suppression system in the event of re
on the cooktop.
12 LOWER REAR ACCESS PANEL
Allows access to Ansul® re suppression agent tank (a6) and
controls also access to main power contactor (41).
a15. DISCHARGE NOZZLE Fire suppression media discharges here (2 places).
16 GREASE BAFFLE Extracts and drains most grease and moisture from the air ow.
18 PRE-FILTER ASSEMBLY
Comprises the PRE-FILTER FRAME and a replaceable PRE-
FILTER. Stops larger particles of grease from reaching the FILTER
PACK for reduced maintenance costs.
19 HEPA/CHARCOAL FILTER PACK
Stops most grease and smoke particles. Also assists in some
cooking odor removal.
22 GREASE CUP Collects grease/moisture drained from grease trough (23).
23 GREASE TROUGH Directs grease/moisture removed by grease bafe to grease cup.
28 VENTILATOR EXHAUST DUCT
Exit point for ventilator airow - on top left rear of unit.
DO NOT BLOCK
a31. STATUS INDICATOR
Displays status of re suppression system (COCKED - FIRED) If
FIRED, a buzzer will sound continuously.
38 POWER CORD 6’ cord and cap. Plug for NEMA 15-60R (receptacle by user).
40 FUSES Provide over-current protection of cooking appliance.
41 POWER CONTACTOR
Energizes cooktop only while ventilator section is sensed as
operational.
42 BUILDING FIRE ALARM RELAY Reports re alarm condition to building re management system.
43 GROUND LUG Ground wire of power cord connects here.
44 INTERLOCK TERMINAL
Provides connection for shut-down control by building re
management system.
53 FILTER INTERLOCK SWITCHES
Proper installation of grease bafe and lter pack close these
switches in ventilator sensor circuit. Provides air movement for
ventilation.
56 VENTILATOR FAN Provides air movement for ventilation.
58 SIDE SPACERS Maintain required 6: spacing from combustible surfaces.
70 COOLING FAN Provides cooling for cooktop controls.
M506 2M-304964 Owners Manual WVOC-4H
M506 2M-304964 Owners Manual WVOC-4H