HW5500/HW5500E Portable Generator Owner’s Manual Portable Gasoline Generator Electric Start Read and Save These Instructions For product inquiries or support, please visit www.honeywellgenerators.com or call toll-free at 1-888-494-3571.
Congratulations on owning a Honeywell portable generator This manual contains important instructions for operating this generator. For your safety, and the safety of others, be sure to read this manual thoroughly before operating the generator. Failure to properly follow all instructions and precautions can cause you and others to be seriously hurt or killed. Please use spaces provided below to write down important information about your generator.
PRODUCT REGISTRATION To register your product, please complete the information below and mail to the mailing address at the end of form, or register online at www.honeywellgenerators.
3 – DEMOGRAPHIC INFORMATION GENDER: MALE HOUSEHOLD INCOME LESS THAN $15,000 FEMALE MARITAL STATUS: MARRIED SINGLE / / DD $125,000 - $149,000 $30,000 - $49,999 $150,000 – $174,999 $50,000 - $79,999 $175,000 – $199,999 $80,000 - $99,999 $200,000 OR OVER PRIMARY METHOD OF PURCHASING HOUSEHOLD ITEMS: DATE OF BIRTH: MM $100,000 - $124,999 $15,000 - $29,999 IN-STORE YYYY ONLINE TV INCLUDING YOUR SELF, HOW MANY PEOPLE LIVE IN YOUR HOUSEHOLD? MAIL ORDER TYPES OF CREDIT CARDS HELD BY HOUSEHOLD MEM
CONTENTS IMPORTANT SAFETY RULES............................................................................................ 1 Safety Messages ............................................................................................................................................1 Location of Important Labels ..........................................................................................................................3 GETTING STARTED ..........................................................
THIS PAGE INTENTIONALLY LEFT BLANK ii www.honeywellgenerators.
SAVE THESE INSTRUCTIONS IMPORTANT SAFETY RULES ANYONE using or servicing generator must read, understand, and follow all safety and operation instructions provided in product manual. Failure to closely follow these instructions can result in circumstances leading to death, serious injury, and property damage.
Safety Messages Electric Shock Hazards Generator produces powerful voltage that can cause death or great physical harm. • When using generator for backup power, notify utility company. Use approved transfer equipment to isolate generator from electric utility. • NEVER connect to a building's electrical system unless a transfer switch has been installed by a qualified electrician. Generator Damage Hazards Improper treatment or misuse of generator can cause permanent damage.
Location of Important Labels Location of Important Labels Your generator is packaged with several labels which provide important safety and maintenance information. Samples of these labels are provided below. Should any of these labels become illegible or damaged, contact Customer Hotline at 1-888-4943571 to request replacements. NOTE: Illustration below shows battery, which is available only with HW5500E models.
THIS PAGE INTENTIONALLY LEFT BLANK 4 www.honeywellgenerators.
GETTING STARTED Use the information in this section to get your generator ready for operation. ANYONE using the generator must read, understand, and follow all safety and operation instructions provided in the product manual. Failure to closely follow these instructions can result in circumstances leading to death, serious injury, and property damage. Unpacking Guidelines Generator is heavy! Lifting generator can cause back or other bodily injury. NEVER lift generator without assistance. 1.
Record Generator Information Record Generator Information It is recommended that you take a moment to write down the identification information specific to your generator in the spaces provided on the inside cover of this Owner’s Manual. You can find this information on generator’s name plate, located on rear side of generator (see illustration below). FIGURE 1: Generator Name Plate Location 6 www.honeywellgenerators.
Assembly Assembly Generator must be empty of engine oil and fuel. Drain engine oil and fuel, if necessary. Generator is heavy! Lifting generator can cause back or other bodily injury. NEVER lift generator without assistance. Wheel Kit FIGURE 2: Wheel Assembly Components i NOTE: Illustration above shows battery, which is available only with HW5500E models.
Assembly Step 1: Install Support Legs 5. To install support legs, you will need: Attach a rubber stopper to bottom of each support leg using a 25 mm full-thread hex bolt and 13 mm flange serrated nut; tighten until securely seated. 25 mm full-thread hex bolts (2) 5/16" washers (2) 13 mm flange serrated nuts (6) 16 mm full-thread hex bolts (4) Socket Wrench with 10 mm Socket* * Not included FIGURE 4: Rubber Stopper Attachment to Support Leg 6. Generator must be empty of engine oil and fuel.
Assembly 4. Slide second 9/16" washer onto axle. To install wheel assembly, you will need: 5. Slide cotter pin into pre-drilled hole until fully seated. Socket wrench with 10 mm socket* 6. Using needlenose pliers, bend each end of cotter pin in opposing directions to secure wheel to axle.
Assembly Step 3: Install Handle Assembly To install handle assembly, you will need: Once properly installed, the handles can be collapsed, if desired. Handle Brackets (2) Hands and fingers can be pinched from collapsible handles. Handle Bars (2) Rubber Handle Grips (2) 40 mm Washer Style Hex Bolts (6) 10 mm flange serrated nuts (6) Socket wrench with 8mm socket* * Not included 1. Hold handle bracket over pre-drilled holes on frame as shown in Figure 9.
Grounding the Generator strap. Carefully cut cable strap to disengage battery lead. Grounding the Generator Generator must be grounded to prevent electrical shock from faulty appliances. • Before using generator, consult a qualified electrician, electrical inspector, or local agency having jurisdiction for local codes or ordinances that apply to the intended use of generator. Before using generator, a ground wire must be connected to the ground terminal (Figure 13).
Using Generator for Backup Power Using Generator for Backup Power Before connecting to building’s electrical system, consult your local utility company or a qualified electrician. Improper connections to a building's electrical system can be deadly. Electrical current from generator to feedback into utility lines. Such feedback may electrocute utility company workers or others who contact utility lines during a power outage. Electrical current can feedback into generator.
COMPONENTS Use information provided in this section to become familiar with your generator’s components. Information below is provided for reference only. Refer to Operation section (page 15) for instructions on operating generator. K J L A E M I B H G C F D FIGURE 14: HW5500/5500E Portable Generator (Illustration shows battery, which is available only with HW5500E models) A—Power Control Center Household Outlets 120V 20 Amp Duplex outlets to connect 120V appliances to generator for power.
THIS PAGE INTENTIONALLY LEFT BLANK 14 www.honeywellgenerators.
OPERATION Preparing for Operation Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell. NEVER use inside a home Only use OUTSIDE and far or garage, EVEN IF doors away from windows, doors, and vents. and windows are open.
Starting Generator 2. Turn fuel valve to ON position. When engine starts, the engine control switch gradually settles at RUN (center) position. i NOTE: While engine is running, a small “trickle” charge is applied to starting battery.This keeps an adequate battery charge. Manual (Recoil) Start: FIGURE 15: Fuel Valve Lever — ON/OFF position 3. Press engine control switch to RUN position. Pull choke control to ON position.
Stopping Generator exceed rated output of generator. Power rating information can usually be found on an appliance’s product label, or stamped inside or on back of appliance. See Table 1 for a listing of average appliance wattage requirements. Stopping Generator In an emergency: Press and hold engine control switch to STOP position until engine stops. In normal use: 1. Turn OFF any connected appliances and unplug any connected power cords. 2. Allow generator to run for 2-3 minutes. 3.
Powering Appliances Appliance Typical Running Watts Dishwasher* 1200-2400 (using drying feature greatly increases energy consumption) Dehumidifier* 785 Electric blanket (Single/Double) 60 / 100 Starting appliances that have motors requires more power. Examples of motorized appliances include refrigerators, water pumps, and furnace blowers. Be sure that power rating of appliance does not exceed that of generator.
MAINTENANCE Maintenance Schedule Periodic maintenance and adjustment is necessary to keep generator in good operating condition. Perform service and inspection at intervals shown in Generator Maintenance Schedule (Table 2). Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell. Accidental starting of generator can cause severe injury or death. Before performing maintenance, disconnect spark plug cap from spark plug.
Engine Oil Oil level should be at “H” or somewhere between the “L” and “H”. Engine Oil Engine oil is a major factor affecting engine performance and service life. Non-detergent and 2-stroke engine oils will damage engine and are not recommended. • Be sure to use engine oils specified under “Engine Oil Recommendations.” It is very important to maintain proper level of engine oil to keep engine in good running condition. • Check engine oil level prior to each use. Refill engine oil if oil level is too low.
Engine Oil Changing Engine Oil 6. Using a socket wrench with 12 mm socket, loosen drain plug bolt; remove drain bolt and sealing washer. Frequent or prolonged contact with engine oil may cause skin cancer. • Immediately after handling engine oil, thoroughly wash hands and any areas of skin exposed to engine oil, with soap and water.
Adding Fuel 14. Reinstall oil fill cap and tighten until fully seated. • i NOTE: Dispose of used motor oil according to guidelines established by your local or state government. Some states (and provinces in Canada) require this information to be posted on the fuel pump. If you notice undesirable operating symptoms, switch to a conventional unleaded gasoline. Adding Fuel Before each use, check fuel gauge on fuel tank. If fuel level is low, refill tank with recommended fuel. NEVER OVERFILL.
Air Filter Maintenance 4. Slowly pour gasoline into fuel tank. Be careful not to overfill. 2. Remove air cleaner cover. FIGURE 29: Fuel Level 5. Reinstall fuel tank cap and fully tighten. i NOTE: Occasional, light spark knock, "pinging", or rattling noise is normal while operating under heavy loads. If spark knock, pinging, or rattling occurs at a steady engine speed, under normal load, drain fuel (page 27) and refill with fresh gasoline. If noise persists, see an authorized generator dealer.
Cleaning Fuel Sediment Cup Soak air filter in clean engine oil and squeeze out excess oil. 7. A Frequent or prolonged contact with engine oil may cause skin cancer. • Thoroughly wash hands and any areas of skin exposed to used oil with soap and water. i NOTE: Engine will smoke during initial start-up if too much oil is left in filter. B C FIGURE 34: Fuel Sediment Cup Assembly Pieces 5. Clean fuel screen (A), o-ring (B), and sediment cup (C), with soap and water. 8. Reinstall air filter. 6.
Cleaning Spark Arrestor Screen 3. Remove spark plug cap. 11. Inspect spark plug washer and verify it is in good con- dition. 12. Reinstall spark plug by hand to prevent cross-thread- ing. 13. After spark plug is seated, tighten with spark plug wrench to compress washer. If installing a new spark plug, tighten l/2 turn after the spark plug seats to compress the washer. If reinstalling a used spark plug, tighten l/8 - l/4 turn after the spark plug seats to compress the washer.
Transporting Generator 4. Pull off enclosure panel. C A Storing Generator Follow service procedures for preparing generator for storage. Inadequate or improper care of generator can result in damage to generator components and will void limited warranty. Before storing generator for extended period of time: B FIGURE 39: Spark Arrestor Assembly 5. Using a screwdriver, loosen and remove screw holding spark arrestor clamp (A). 6. Slide off spark arrestor clamp. 7.
Storing Generator Draining Fuel 1. Turn fuel lever to OFF position. 2. Run engine until it stops due to lack of fuel. 3. Place suitable container underneath drain hole to catch fuel. 4. Loosen bolt (underneath fuel sediment cup). FIGURE 40: Loosen Bolt to Drain Fuel 5. Turn fuel lever to ON position. FIGURE 41: Fuel Valve Lever — ON/OFF position 6. Allow fuel to drain into container. 7.
THIS PAGE INTENTIONALLY LEFT BLANK 28 www.honeywellgenerators.
TROUBLESHOOTING ANYONE using or servicing generator must read, understand, and follow all safety and operation instructions provided in the product manual. Failure to closely follow these instructions can result in circumstances leading to death, serious injury, and property damage. Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell.
THIS PAGE INTENTIONALLY LEFT BLANK 30 www.honeywellgenerators.
SPECIFICATIONS HW5500 HW5500E Length 27 inches (685.8 mm) 27 inches (685.8 mm) Width 21.5 inches (546.1 mm) 21.5 inches (546.1 mm) Height 21.5 inches (546.1 mm) 21.5 inches (546.1 mm) 185 lb (83.9 kg) 195 lb (88.
THIS PAGE INTENTIONALLY LEFT BLANK 32 www.honeywellgenerators.
WARRANTIES E. Fuel tank, cap and screen F. Carbon Canister (if equipped) NORTHSHORE POWER SYSTEMS EMISSIONS CONTROL WARRANTY Honeywell Portable Generator 2. A. Air cleaner B. Vent lines C. Intake manifold WARRANTY STATEMENT US Environmental Protection Agency (EPA) requires manufacturers of small off-road engines (SORE) to warranty their products with a 2 year warranty for those components that are specified as being part of the emission control system.
NORTHSHORE POWER SYSTEMS EMISSIONS CONTROL WARRANTY QUESTIONS If you have questions regarding your emissions warranty rights and responsibilities, you should contact the Warranty and Service department at NSP. By phone: (414) 332-2375 Via web: www.honeywellgenerators.com By US mail: Northshore Power Systems, LLC Attention: Product Warranty and Service Dept. 4425 N Port Washington Road Suite 105 Milwaukee WI 53212-1082 34 www.honeywellgenerators.
NORTHSHORE POWER SYSTEMS LIMITED WARRANTY NORTHSHORE POWER SYSTEMS LIMITED WARRANTY Honeywell Portable Generator Effective April 1, 2008 LIMITED WARRANTY Northshore Power Systems, LLC, (NSP) will repair or replace, free of charge, to the original retail customer, in North America, any parts of the portable generator found by NSP or an authorized service center to be defective in material or workmanship. This limited warranty covers the cost of the replacement parts and labor for defects.
THIS PAGE INTENTIONALLY LEFT BLANK 36 www.honeywellgenerators.
INDEX INDEX stopping 17 storing 26 transporting 26 unpacking guidelines 5 warranty 35 Ground 11 special requirements 11 terminal 13 A Air Filter maintenance 23 Appliances powering 17 rules for powering 17 wattage information 17 Assembly battery 10 handle 10 wheels 9 H Handles installing 10 High Altitude operation 17 C Checklist generator shipment 5 Components and Controls breakers 13 choke control 13 engine switch 13 fuel valve 13 outlets Household 13 Transfer Switch 13 recoil starter grip 13 spark plug
INDEX U Unpacking guidelines 5 W Warranty emissions control 33 limited product 35 Wattage typical appliance 17 Wheels installing 9 38 www.honeywellgenerators.
HW5500/5500E MAINTENANCE PARTS To order maintenance parts, visit www.honeywellgenerators.com or call Customer Hotline at 1-888-494-3571.
Northshore Power Systems, LLC 4425 N. Port Washington Rd., Suite 105 Milwaukee, WI 53212-1082 USA HW5500/5500E – P/N: 100900A March 2008 © 2008 Northshore Power Systems, LLC TEL 1-888-494-3571 The Honeywell Trademark is used under license from Honeywell International Inc. www.honeywellgenerators.com Honeywell International Inc.