-GALLON AIR COMPRESSOR 224876 Model # 2281 For replacement parts visit WENPRODUCTS.COM bit.ly/wenvideo IMPORTANT: Your new tool has been engineered and manufactured to WEN’s highest standards for dependability, ease of operation, and operator safety. When properly cared for, this product will supply you years of rugged, trouble-free performance. Pay close attention to the rules for safe operation, warnings, and cautions.
TABLE OF CONTENTS Technical Data General Safety Rules Specific Rules for Air Compressors Electrical Information Know Your Compressor Operation Maintenance Troubleshooting Parts List & Exploded View Warranty 2 3 4 6 7 8 10 11 12 14 TECHNICAL DATA Model Number: Motor: Capacity: Max PSI: Approximate Cut-in Pressure: Approximate Cut-out Pressure: Air Outlet: Air Flow: Compression Process: Product Dimensions: Weight: 2 2281 120V, 3.5A, 60 Hz 1 Gallon 125 PSI 95 PSIG 125 PSIG Quick-Coupler, 1/4˝ NPT 0.
GENERAL SAFETY RULES Safety is a combination of common sense, staying alert and knowing how your item works. SAVE THESE SAFETY INSTRUCTIONS. WARNING! Read all safety warnings and all instructions. Failure to follow the warnings and instructions may result in electric shock, fire and serious injury. To avoid mistakes and serious injury, do not plug in your tool until the following steps have been read and understood. WORK AREA SAFETY 1. Keep work area clean and well lit.
GENERAL SAFETY RULES POWER TOOL USE AND CARE 1. Avoid accidental start-ups. Make sure the power switch is in the OFF position before connecting the plug to a power source or carrying the tool. 2. Check power tool for damaged parts. Check for misalignment of moving parts, jamming, breakage, improper mounting, or any other conditions that may affect the tool’s operation. Do not use the power tool if the switch does not turn ON/OFF. Any part that is damaged should be properly repaired or replaced before use.
SPECIFIC RULES FOR AIR COMPRESSORS 5. Keep your air compressor in a well-ventilated area. Do not cover during use. 6. Do not spray flammable liquids in a confined area or towards a hot surface. The spray area must be well-ventilated. Do not smoke while spraying. Do not spray when a spark or flame is present. 7. Do not adjust the regulator higher than the marked maximum pressure of any attached pneumatic tools or equipment. 8. Do not direct the air stream at people or animals. 9.
ELECTRICAL INFORMATION GROUNDING INSTRUCTIONS IN THE EVENT OF A MALFUNCTION OR BREAKDOWN, grounding provides the path of least resistance for an electric current and reduces the risk of electric shock. This tool is equipped with an electric cord that has an equipment grounding conductor and a grounding plug. The plug MUST be plugged into a matching outlet that is properly installed and grounded in accordance with ALL local codes and ordinances. DO NOT MODIFY THE PLUG PROVIDED.
KNOW YOUR AIR COMPRESSOR Carefully unpack the air compressor from the box. Check all components and compare against the graph below. If any part is damaged or missing, please contact our customer service at (800) 232-1195, M-F 8-5 CST.
OPERATION TURNING THE COMPRESSOR ON & OFF (Fig. 1) 1. Move the switch to the left to set the tool to ON/AUTO mode. 2. Move the switch to the right to set the tool OFF mode. AU TO CLOSING & OPENING THE TANK DRAIN VALVE (Fig. 2) 1. Before operation, close the tank drain valve by moving the valve clockwise (perpendicular to the drain tube). 2. After operation, drain the tank by moving the tank drain valve counterclockwise (in line with the drain tube) to open. OFF Fig.
OPERATION SHUTTING DOWN THE COMPRESSOR 1. Turn the pressure switch to the OFF position. Then unplug the power cord. 2. Reduce pressure in the tank through the outlet hose or by pulling the pressure relief valve ring (Fig. 4 - 1). This is an emergency overpressure relief. When pulled open, it will lower the pressure down to 75 PSI and close automatically. To lower the pressure below 75 PSI or to drain the tank, pull on the ring and hold it open. 3.
MAINTENANCE WARNING: Always shut off and unplug the compressor and relieve all air pressure from the system before performing any cleaning or inspection on the air compressor. CLEAN AND INSPECT DAILY 1. Pull the pressure release valve ring to open the valve after each operation (Fig. 4). 2. Open the tank drain valve (Fig. 2) underside the compressor to drain the tank daily after each operation.
TROUBLESHOOTING CAUTION: Stop using the tool immediately if any of the following problems occur or risk serious personal injury. Have the repair or replacement performed by a qualified service technician before operating this tool. Problem Air leaks from the regulator. Regulator does not regulate pressure any more. Low PSI pressure and/or compressor does not stop. Common Causes Solution The regulator has become damaged Replace the regulator/internal parts. or dirty. 1. Tank drain valve is open. 2.
EXPLODED VIEW AND PARTS LIST 12
EXPLODED VIEW AND PARTS LIST No. Part No.
LIMITED TWO YEAR WARRANTY WEN Products is committed to building tools that are dependable for years. Our warranties are consistent with this commitment and our dedication to quality. LIMITED WARRANTY OF WEN CONSUMER POWER TOOLS PRODUCTS FOR HOME USE GREAT LAKES TECHNOLOGIES, LLC (“Seller”) warrants to the original purchaser only, that all WEN consumer power tools will be free from defects in material or workmanship for a period of two (2) years from date of purchase.
THANKS FOR REMEMBERING