HEAVY DUTY AIR FILTRATION SYSTEM CSA MODEL TA25 184841 For replacement filters visit WENPRODUCTS.COM bit.ly/wenvideo IMPORTANT: Your new tool has been engineered and manufactured to WEN’s highest standards for dependability, ease of operation, and operator safety. When properly cared for, this product will supply you years of rugged, trouble-free performance. Pay close attention to the rules for safe operation, warnings, and cautions.
TABLE OF CONTENTS Technical Data General Safety Rules Specific Safety Rules For Air Filtration Systems Electrical Information Unpacking Know Your Air Filtration System Assembly and Adjustments Operation Maintenance Exploded View & Parts List Warranty 2 3 4 5 6 6 7 8 9 10 12 TECHNICAL DATA Model Numbers: Motor: Air Flow: 3415, 3415T 110-120 V, 60 Hz, 3A 1044 CFM (High Speed) 702 CFM (Medium Speed) 556 CFM (Low Speed) Air Filters: 5-Micron Outer Air Filter - Model 3415AF5 1-Micron Inner Air Filter - Model
GENERAL SAFETY RULES Safety is a combination of common sense, staying alert and knowing how your item works. SAVE THESE SAFETY INSTRUCTIONS. WARNING: To avoid mistakes and serious injury, do not plug in your tool until the following steps have been read and understood. 1. READ and become familiar with this entire instruction manual. LEARN the tool’s applications, limitations, and possible hazards. 2. AVOID DANGEROUS CONDITIONS. Do not use power tools in wet or damp areas or expose them to rain.
GENERAL SAFETY RULES 15. DO NOT OVERREACH. Keep proper footing and balance at all times. Wear oil-resistant rubber-soled footwear. Keep the floor clear of oil, scrap, and other debris. 16. MAINTAIN TOOLS PROPERLY. ALWAYS keep tools clean and in good working order. Follow instructions for lubricating and changing accessories. 17. CHECK FOR DAMAGED PARTS. Check for alignment of moving parts, jamming, breakage, improper mounting, or any other conditions that may affect the tool’s operation.
ELECTRICAL INFORMATION GROUNDING INSTRUCTIONS IN THE EVENT OF A MALFUNCTION OR BREAKDOWN, grounding provides the path of least resistance for an electric current and reduces the risk of electric shock. This tool is equipped with an electric cord that has an equipment grounding conductor and a grounding plug. The plug MUST be plugged into a matching outlet that is properly installed and grounded in accordance with ALL local codes and ordinances. DO NOT MODIFY THE PLUG PROVIDED.
UNPACKING Carefully unpack the air filtration system and all its parts. Check all components and compare against the list below. Do not discard the carton or any packaging until the air filtration system is completely assembled. If any part is damaged or missing, please contact our customer service at (800) 232-1195, M-F 8-5 CST. • Air Filtration System with Inner and Outer Filters Installed • Mounting Hangers (4) • Mounting Brackets (4) • Hex Wrenches (2) • M6 X 4.
ASSEMBLY AND ADJUSTMENTS WARNING: To prevent serious injury from accidental operation, make sure the power cord is disconnected from the power source and the tool is switch to OFF before assembly or making any adjustments. The air filtration system is designed to circulate air and filter wood and other non-metallic dust. To achieve the best performance possible, it is important to consider how and where to place the unit. When selecting a site, make sure there is a suitable power source nearby.
OPERATION TURNING ON/OFF AND SETTING THE SPEED (Fig. 4 & 5) The air filtration system can be operated using the control panel or with the remote control. 1. Plug the power cord into an appropriate power source. 2. Press the ON/SPEED button on the control panel (Fig. 4 - 1) or the remote control (Fig. 5 - 1) to power on the air filtration system. The air filtration system will start running at low speed. The “LO” LED will light up on the panel, indicating that the unit is operating at low speed. 3.
MAINTENANCE WARNING: To reduce the risk of injury and electric shock, unplug the air filtration system from the power source before changing the air filters or servicing the unit. CHANGING THE FILTERS (Fig. 6 & 7) Check the inner and outer filters periodically depending on the amount of use and the environment of the shop. Change the filters when needed. Clogged filters will reduce the amount of air circulating through the filter and possibly overload the unit.
47 43 46 1 27 2 11 12 10 57 44 2 56 34 45 39 31 38 40 36 22 37 35 42 41 28 33 21 23 1 25 26 9 24 30 29 55 51 5 6 50 52 58 8 20 7 4 18 3 13 53 54 14 19 17 16 15 EXPLODED VIEW & PARTS LIST
EXPLODED VIEW & PARTS LIST No. Part No. 1 3415-001 2 3415-002 3 3415-003 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 3415-004 3415-005 3415-006 3415-007 3415-008 3415-009 3415-010 3415-011 3415-012 3415-013 3415-014 3415-015 3415-016 3415-017 3415-018 3415-019 3415-020 3415-021 3415AF1 3415-023 3415AF5 3415-025 3415-026 3415-027 3415-028 Description Phillip’s Head Screw M6-1X16 Lock Washer 6mm Phillip’s Head Screw M4-0.7X2 Fan Housing Cap Screw M6-1X20(LH) Flange Disk 6.
LIMITED TWO YEAR WARRANTY WEN Products is committed to building tools that are dependable for years. Our warranties are consistent with this commitment and our dedication to quality. LIMITED WARRANTY OF WEN CONSUMER POWER TOOLS PRODUCTS FOR HOME USE GREAT LAKES TECHNOLOGIES, LLC (“Seller”) warrants to the original purchaser only, that all WEN consumer power tools will be free from defects in material or workmanship for a period of two (2) years from date of purchase.