MODEL 3417 HEAVY DUTY AIR FILTRATION SYSTEM For replacement parts visit 4005867 WENPRODUCTS.COM IMPORTANT: Your new tool has been engineered and manufactured to WEN’s highest standards for dependability, ease of operation, and operator safety. When properly cared for, this product will supply you years of rugged, trouble-free performance. Pay close attention to the rules for safe operation, warnings, and cautions.
TABLE OF CONTENTS Technical Data.................................................................................2 General Safety Rules........................................................................3 Safety Rules For Air Filtration Systems..............................................5 Electrical Information.......................................................................6 Unpacking........................................................................................
GENERAL SAFETY RULES Safety is a combination of common sense, staying alert and knowing how your item works. SAVE THESE SAFETY INSTRUCTIONS. WARNING: To avoid mistakes and serious injury, do not plug in your tool until the entire instruction manual and all labels affixed to the tool have been read and understood. WORK AREA SAFETY 1. Keep work area clean and well lit. Cluttered or dark areas can cause accidents. Do not work on floor surfaces that are slippery with sawdust or wax. 2.
GENERAL SAFETY RULES POWER TOOL USE AND CARE 1. Avoid accidental start-ups. Make sure the power switch is in the OFF position before connecting to power source, picking up or carrying the tool. 2. Check power tool for damaged parts. Check for misalignment of moving parts, jamming, breakage, improper mounting, or any other conditions that may affect the tool’s operation. Do not use the power tool if the switch does not turn ON/OFF. Any part that is damaged should be properly repaired or replaced before use.
SAFETY RULES FOR AIR FILTRATION SYSTEMS WARNING: Do not let comfort or familiarity with the product replace strict adherence to product safety rules. Failure to follow the safety instructions may result in serious personal injury. 1. To reduce the risk of injury and electric shock hazards, disconnect the air filtration system from the power source before making adjustments, servicing or changing filters. 2.
ELECTRICAL INFORMATION GROUNDING INSTRUCTIONS IN THE EVENT OF A MALFUNCTION OR BREAKDOWN, grounding provides the path of least resistance for an electric current and reduces the risk of electric shock. This tool is equipped with an electric cord that has an equipment grounding conductor and a grounding plug. The plug MUST be plugged into a matching outlet that is properly installed and grounded in accordance with ALL local codes and ordinances.
UNPACKING Carefully unpack the air filtration system and all its parts. Check all components and compare against the list below. Do not discard the packaging until the air filtration system is completely assembled. If any part is damaged or missing, please contact our customer service at (800) 232-1195, M-F 8-5 CST or email techsupport@wenproducts.com. • Air Filtration System with Inner and Outer Filters Installed • Mounting Hangers (4) • Mounting Brackets (4) • Hex Wrenches (2) • M6 X 4.
ASSEMBLY & INSTALLATION WARNING: To prevent serious injury from accidental operation, make sure the power cord is disconnected from the power source and the tool is switch to OFF before assembly or making any adjustments. The air filtration system is designed to circulate air and filter wood and other non-metallic dust. To achieve the best performance possible, it is important to consider how and where to place the unit. When selecting a site, make sure there is a suitable power source nearby.
ASSEMBLY & INSTALLATION CEILING MOUNTING (FIG. 3) WARNING: Only anchor the air filtration system to building structures capable of holding AT LEAST 100 lbs. Do not mount the air filtration system to non-structural surfaces such as dry wall or false ceiling grids. The unit must be situated at least 7 feet above the floor and at least 3 feet (1 m) away from any heating, cooling, or air circulation vents. 1. Install the wood screw hooks (Fig. 4 - 1) into the building support structure.
OPERATION TURNING ON/OFF AND SETTING THE SPEED (FIG. 5 & 6) The air filtration system can be operated using the control panel or with the remote control. 1. Plug the power cord into an appropriate power source. 2. Press the ON/SPEED button on the control panel (Fig. 5 - 1) or the remote control (Fig. 6 - 1) to power on the air filtration system. The air filtration system will start running at low speed. The “LO” LED will light up on the panel, indicating that the unit is operating at low speed. 3.
MAINTENANCE CHANGING THE FILTERS (FIG. 7, 8, 9) Check the inner and outer filters periodically, depending on the amount of use and the environment of the shop. Change the filters when needed. Clogged filters will reduce the amount of air circulating through the filter and possibly overload the unit. 1 Replacement filters for this unit are available in two packs at wenproducts.
MAINTENANCE REPLACING THE REMOTE CONTROL BATTERIES 1. Open the remote control battery compartment on the back of the remove control. 2. Replace the used batteries with 2 new AAA batteries. 3. Close the battery compartment. CHECKING AND REPLACING THE FUSE (FIG. 10) If the unit is overloaded, the line inside the fuse will break to cut the circuit and protect the unit. To replace the fuse: 1. Turn the fuse cap (Fig. 10 - 1) counterclockwise to loosen and pull the fuse (Fig. 10 - 2) out of the control panel.
WARRANTY STATEMENT WEN Products is committed to building tools that are dependable for years. Our warranties are consistent with this commitment and our dedication to quality. LIMITED WARRANTY OF WEN CONSUMER POWER TOOLS PRODUCTS FOR HOME USE GREAT LAKES TECHNOLOGIES, LLC (“Seller”) warrants to the original purchaser only, that all WEN consumer power tools will be free from defects in material or workmanship for a period of two (2) years from date of purchase.
EXPLODED VIEW & PARTS LIST 35 34-ASM 36 37 38 39 40 41 42 43 34 33 32 44 31 30 46 29 28 27 48 45 47 26 25 24 49 23 50 22 21 20 53 19 18 17 16 15 14 51 13 12 11 14 10 9 8 7 6 5 4 3 2 1 52
EXPLODED VIEW & PARTS LIST No. Part No. Description Qty. No. Part No. Description Qty.
THANKS FOR REMEMBERING