Use and Care Manual

9
OPERATION
ADJUSTING THE DRIVING DEPTH
WARNING: To reduce risk of serious injury from accidental actuation when attempting to adjust depth,
always disconnect the air supply and avoid contact with trigger during adjustments.
1. To drive a nail shallower, rotate the depth setting wheel to the right.
2. To drive a nail deeper, rotate the depth setting wheel to the left.
CLEARING A JAMMED NAIL
WARNING: Disconnect air line from tool and remove fasteners from magazine before making adjust-
ments or personal injury may result.
If a nail becomes jammed in the nosepiece, keep the tool pointed away from you and follow these instructions:
1. Disconnect the air supply from the tool.
2. Open the magazine. Pull down the door latch and swing the door open. The door swings to the left. Swing
magazine cover open. Magazine cover swings to the right.
3. Remove jammed nail. Use pliers if necessary.
4. If the piston assembly is in the down position, insert screwdriver or other rod into nosepiece and push the pis-
ton back into position.
5. Remove the rod and close the magazine.
6. Make sure the trigger and safety bracket move freely without sticking or binding.
7. Load nails into magazine (see the previous “Loading the Fasteners” section).
8. Reattach the air supply.
TO CHANGE THE TRIGGER (FIG. H)
WARNING: Disconnect air line from tool and remove fasteners from
magazine before making adjustments or personal injury may result.
To swap out the trigger switch:
1. Remove the o-ring on the side of the trigger pin.
2. Remove the trigger pin, the trigger and the trigger spring.
3. Swap the trigger switch out for the alternative trigger.
4. Replace the trigger spring, the trigger, the trigger pin and the o-ring.
Fig. H
FIRING NAILS
WARNING: To reduce the risk of injury, always wear proper eye and hearing protection when operating
this tool.
WARNING: If the red trigger is installed, a nail will fire each time the trigger is pressed as long as the
safety bracket remains activated. This could result in inadvertent actuation.
For sequential fire, press the safety bracket firmly against the work surface. Then, pull the trigger to shoot a nail.
For bump fire, hold the trigger down. Then, press the safety bracket against the surface to fire the nail.
Sequential fire and bump fire both require the red trigger to be installed. For single fire, install the black trigger.
This means that both the trigger and the safety bracket need to be disengaged between each fired nail.