8
Ultra-low consumption shut down mode
Digital received signal strength indicator(RSSI)
Configurable date packet structure
Operating Temperature Range:-40 ~ +85°C
Applications
Automated Meter Reading
Home and Building Automation
Wireless Alarm and Security Systems
Industrial Monitoring and Control
Long range Irrigation Systems
Electrical Characteristics
Test Conditions: T
A
= 25°C, 3.3V, F
c
= 915 MHz
Parameter Value Note
Frequency range 862-960MHz
1
Frequency error ±10ppm
Frequency drift ±20ppm -40°C~85°C
Modulation
FSK/GFSK/MSK/
GMSK/LoRa/OOK
Date Rate 0.18-37.5kbps
2
Working at LoRa Mode
TX Power 18dBm±1dB 862-960MHz
Spurious Emission ≤-30dBm
TX Current ≤130mA
3
862-960MHz
RX Sensitivity -134dBm
4