User's Manual

7 – 9
Operating data
D101583 0207 BL ident
7
Operating data for read-write head
– TB-M30-H1147/S1126
Table 7:
Operating data
TB-M30-H1147/
S1126
Corresponding
data carrier
Read-write distance
Recommended
[mm]
Maximum
[mm]
TW-R16-B128 12 23
TW-R20-B128 15 27
TW-R30-B128 13 30
TW-R50-B128 20 43
TW-R22-HT-B64 5 17
TW-R50-90-HT-B128 5 10
TW-I14-B128 15 27
TW-L43-43-F-B128 25 42
TW-L82-49-P-B128 20 43