Deep Cleaning Bagless Vacuum with Powerhead Deep Clean W3000 User Manual
Features 8 1 On/off button 2 Flexible hose 3 Telescopic wand 4 Wand length adjustment 5 Cord rewind button 6 Combination floor brush 7 Dust canister 8 Combination floor tool 9 Mini hand turbo tool 10 Dusting brush 11 Crevice tool 9 10 11 4 3 2 5 7 1 6
Congratulations on the purchase of your new Wertheim vacuum cleaner. There are many useful features built into your cleaner and we recommend that you carefully read this instruction manual so that you may take best advantage of them. Due to our program of continuous product improvement and innovation, sometimes the product you buy may differ slightly from the one shown on this product carton/manual.
BEFORE YOU BEGIN The cleaner must be operated in accordance with these instructions and used only for domestic household cleaning to remove DRY dirt and dust from household carpets, flooring and fabrics. This cleaner is not fit to be used as an industrial cleaner, and is not designed for the collection of vitreous building material including particle board, construction products and similar products such as wood/fibres, cement, fillers, fibre glass etc or excessive or frequent sand.
Important Always switch off the cleaner and remove the plug from the electricity power supply before cleaning your appliance, when not in use or attempting any maintenance task. The cleaner must only be connected to an AC power supply at the voltage shown on the rating label. This cleaner should only be used for its intended purpose as described in this instruction manual. Never operate the vacuum cleaner without filters.
SAFETY INSTRUCTIONS (cont’d) 8. Ensure the appliance is switched off before unplugging. 9. Do not handle or operate the appliance with wet hands and follow electrical safety precautions at all times. 10. Extreme caution should be exercised when using the appliance on stairs. 11. Do not attempt to change the attachments while the appliance is plugged in to mains power supply. Switch off and remove plug from mains power supply. Use only manufacturer’s recommended accessories. 12.
24. Do not use the vacuum cleaner if it is damaged or breaks down. Check the electrical regularly for defects. If connection cables, electrical hoses, electrical contacts and electric tubes are damaged, have them replaced immediately. 25. Never clean the vacuum cleaner or any of the electrical parts, especially the electrical connections with water or liquid cleaners. 26. Never attempt to make any modifications electrically to the vacuum cleaner. 27.
Instructions For Use Before using, unwind a sufficient length of cable and insert the plug into the power socket. A yellow mark on the power cable shows the ideal cable length. Do not extend the cable beyond the red mark. 6 1. Press the on/off button to turn the vacuum on. 2. To rewind the power cable, press the rewind button with one hand and guide the cable with the other hand to ensure that it does not whip, causing damage to the cable.
The cleaner should be switched off and disconnected from the mains power supply before you start to assemble. 1. Connect the hose body connector to the cleaner making sure it fits firmly. 2. Fit handle into the telescopic wand until it clicks into place. 3. Extend or reduce the length of the wand by depressing button and moving the slider.
INSTRUCTIONS FOR USE (cont’d) Assembling your Cleaner cont. 8 4. Push the wand into the powerhead until it clicks into place. To remove, press button and separate. 5. The powerhead can be controlled by the on/off switch on the handle. 6. Also provided is a combination floor tool. 7. Do not extend the power cable further than the yellow mark.
The use of a powerhead is recommended for the optimal cleaning of carpets. The rotating design allows the powerhead to move in any direction, making it easily manoeuvrable around obstacles. Safety Precautions 1. Keep hair, hands and feet away from the rotating brush roller while the powerhead is running. 2. Remember the powerhead will operate whenever it is connected to a running vacuum. If children are present, make sure to turn the vacuum system off when leaving powerhead unit unattended. 3.
MAINTENANCE How to Clear Blockages • Low suction or pick up may be due to a blockage in the system. Refer to the following steps to check for blockages, continuing with each step until the blockage is found. Hose/Wand Blockage • Disconnect the powerhead and telescopic wand from handle. • P lug vacuum in and turn it on. Check the hose end for suction. Remove any obstructions. • If there is no blockage in the hose, remove the powerhead from the telescopic wand and attach the wand to the hose.
Step 4: Remove any dirt or hair from the roller brush. Step 5: Replace the clear cover. Step 6: Lock the neck on the Mini Hand Turbo Brush by twisting clockwise. Step 7: Rotate the external bristles down and lock the side release buttons by pushing upwards.
MAINTENANCE (cont’d) Emptying and Cleaning the Cyclonic Separator (Dust Canister) The cleaner should be switched off and disconnected from the mains power supply before you start to empty or disassemble. 12 1. Press the dust canister release button to remove canister from cleaner. 2. To empty dust canister, press release button and dispose of dirt. 3. Hold canister body and rotate handle anti-clockwise lining the arrow up with the lock symbol.
Separate items for cleaning. Reassembly is a reversal of Step 3. 5. With a cloth dampened with water, clean all surfaces of the separator and canister and dry thoroughly. 6. When thoroughly dried, refit canister to handle/separator assembly and fit back into cleaner. Deep Clean W3000 4.
MAINTENANCE (cont’d) Changing Filters The cleaner should be switched off and disconnected from the mains power supply. Never operate without filters as overheating and damage to cleaner could occur. 14 1. To remove HEPA filter rotate wheel hub anti-clockwise. 2. Remove HEPA filter from wheel hub and discard. 3. Depending on usage, replace HEPA filter every 6 –12 months. Dirty filters will reduce performance.
To replace the motor filter, remove canister and locate the filter cover indentations A and B. 5. Lift filter cover by placing fingers into indentations. 6. The motor filter, if clogged or dirty, must be replaced. Deep Clean W3000 4.
TROUBLESHOOTING Service problems that appear to be major can often be solved easily. You can be your own troubleshooter by reviewing this guide. All other servicing should be done by an authorised service agent or qualified technician. Problem Cause Remedy Motor does not start or stops. No power supply. Check cable, plug and socket. If still inoperative, contact Customer Service. Suction force gradually decreases. Dust canister is full, suction hose, wand is blocked or clogged filters.
Online www.wertheim.net.au www.wertheim.co.nz Deep Clean W3000 This warranty on your cleaner commences from the original date of purchase and is not transferable; please retain your original proof of purchase for any warranty claims. This warranty is valid only in the country where the cleaner is purchased. The cleaner must be operated in accordance with these instructions and used only for domestic household cleaning to remove DRY dirt and dust from household carpets, flooring and fabrics.
International Cleaning Solutions Pty. Ltd. ACN 119 462 798 Level 1, Building 2, Brandon Business Park 530 Springvale Road, Glen Waverley, Victoria 3150 www.wertheim.net.au www.wertheim.co.nz enquiries@wertheim.net.