Troubleshooting (cont’d)
Diagnosing Faults
The controller includes a number of features designed to help the user track down operational, wiring, or
internal controller faults. The diagnostic LED mounted next to the calibrator connectors on the front of the
controller serves as a simple diagnostic tool. Use the table below to identify faults. Faults are cleared by
re-initiating the start sequence.
Diagnostic LED Flash Fault Descriptions
LED Display Description
ON No fault, normal conditions
OFF Internal controller fault
1 Flash Personality out of range
2 Flashes Illegal start condition (Traction)
3 Flashes MOSFET Short circuit
4 Flashes Contactor fault or motor open circuit
5 Flashes Motor stalled
6 Flashes Accelerator wire off fault
7 Flashes Low or high battery voltage or BDI cutout operating
8 Flashes Over temperature or timed cutback
9 Flashes Internal monitor function tripped / Maintenance required
10 Flashes Power up autozero has not been completed
Calibrator Fault Identifi cation Codes
In addition to the LED indication, a more detailed description of the fault may be found by using the
calibrator. Menu item 13.01 gives a fault identifi cation code which further defi nes the detected fault. The
following table lists the fault ID codes.
ID Code Fault Name Flash Fault
0 NO_FAULT LED_ON
1 UNIT_TOO_HOT 8
2 MONITOR_TRIPPED 11
3 I2T_CURRENT_LIMIT 8
4 MOTOR_TOO_HOT 12
5 MAINTENANCE_CLOSE_FAULT 9
6 ACCELERATOR_FAULT 6
7 ACCELERATOR_POWER_UP_FAULT 6