Installation Guide

Options
Shower arm range
Fixed head arms – easyfit
Wall mounted
Cut the outlet pipe to the finished length (55mm – 150mm measured from the finished
wall surface) using a rotary type cutter. If a hacksaw is used, the pipe end must be
carefully de-burred and chamfered.
1
Slide the wall spacer down the projecting pipe flush with
the finished wall surface.
2
Ensure the pipe is clean and free of dust and slide the
fixing bush onto the pipe flush with the finished wall
surface.
3
Slide the fixed head arm over the fixing bush flush with the wall surface and mark the
four fixing points.
4
Carefully remove the fixed head arm and drill and prepare the fixings using the fixings
provided, if suitable, taking care to avoid pipework hidden in the wall.
5
Ensuring the fixing bush is clean and free of dust, fit the
15mm ‘O’ring against the end of the fixing bush.
Lubricate the ‘O’ring using a suitable silicone base
lubricant.
6
Refit the shower arm and secure it to the wall using the
screws provided.
7
Run the shower for a few seconds to clear any debris that may be present.
8
Slide the cover plate into position flush with the finished
wall surface.
9
Ceiling mounted
The ceiling mounted fixed head is supplied with screws for fixing the product to a noggin.
A NOGGIN MUST BE USED AS PART OF THIS INSTALLATION
!
Run a 15mm outlet pipe from the valve/processor to the preferred position for the fixed
head.
1
Locate the position for the fixed head in the bathroom
and firstly drill a pilot hole to mark the position before
checking that there is suitable space behind the ceiling
for the fixing assembly.
2
The minimum height required behind the ceiling is 50mm and the space must allow for
an 80mm wide, 50mm deep noggin to be used to support the assembly.
!
Drill a hole (minimum ø28mm, maximum ø40mm) through the ceiling and the noggin.
3
Remove the fixing bracket carefully from the fixed head arm.
4
Set the fixing bracket into position and mark the fixing
points. Remove the bracket and drill and prepare
suitable fixings. Refit the fixing bracket and secure it
through the ceiling and into the noggin using the
screws provided if suitable.
5
Feed the arm through the fixing bracket to the correct
depth. Tighten the nut using a 32mm spanner if
necessary to facilitate.
6
Cut off the excess pipe allowing for a suitable working length to allow for the required
22mm connection. If a push fit connector is to be used then the pipe must be abraded
to remove all chrome plating.
7
Connect the pipe work from the valve, diverter or processor to the end of the fixed head
pipe using a suitable coupling.
8
Run the shower for a few seconds to clear any debris and to check for any leaks.
!
Lubricate the ‘O’ ring if necessary and carefully
slide the cover plate back over the fixed head arm
and into position against the ceiling.
9
Secure the cover plate to the arm using the grub screw
and 2.5mm hexagonal key provided.
10
The ‘O’ ring must be positioned on the 15mm pipe up to
the fixing bush, not onto the fixing bush shaft.
!

Summary of content (2 pages)