User's Manual

-6-
The CSI-repeater incorporates the following features for convenient operation, access, protection, and control.
Control using a Windows based Graphical User Interface
and accessed by connecting a laptop or desktop computer
the NMS 9 pin sub-D serial port.
User Gain Control
Automatic Level Control
Automatic Shut Down Function
Oscillation Protection
Over Drive Protection
Under/Over Voltage Protection
Fault Protection
Alarm Notifi cation
External Interfaces - Serial
Persistent Status and Error information
Feature Overview
A complete line of accessories is available from Cellular Specialties, Inc. Check with your CSI distributor for any additional items
needed. Below are just a few examples suitable for most in-building needs.
Directional Couplers
6dB - model number: CSI-DC6/700-2.7K/N
10dB - model number: CSI-DC10/700-2.7K/N
15dB - model number: CSI-DC15/700-2.7K/N
20dB - model number: CSI-DC20/700-2.7K/N
30dB - model number: CSI-DC30/700-2.7K/N
Outside Donor Antenna
Panel - model number: CSI-AP/698/2.7K/7-10
UPS
Battery backup, 2 hr Single band
1 hour dual band - model number: CS48-985-600
Battery backup, 4 hr Single band
2 hour dual band - model number: CS48-985-601
Power Dividers
2:1 - model number: CSI-SPD2/700-2.7K/N
3:1 - model number: CSI-SPD3/700-2.7K/N
4:1 - model number: CSI-SPD4/700-2.7K/N
Grounding Kit - model number: CSI-GKIT
Lightning Arrestor - model number: CSI-CAP
Inside Omnidirectional Antenna
Quad-band - model number: CSI-AO/700/2.7K/3
Optional Accessories
Inadequate isolation between the outside and inside antennas may cause regenerative feedback in the system. This feedback can
cause the amplifi er to emit a continuous signal at maximum amplitude and, in some cases, interfere with normal operation of the donor
site. Careful consideration of the layout and placement of the system is imperative to minimize this possibility and to minimize the amount
of signal leaking from the building. See installation tips for general guidelines.
The installer should refer to the Safety Guidelines section and the Important Safety Information section for proper antenna selection
and installation. To avoid serious injury or death and damage to the repeater, do not install donor or server antennas near overhead power
lines or high power components. Allow enough distance so that if antennas should fall they will not come in contact with those compo-
nents.
Close proximity to the donor or server antennas with the repeater in operation may expose the user or installer to RF fi elds that
exceed FCC limits for human exposure.
WARNING! AMPLIFIER OR HANDSET DAMAGE MAY OCCUR IF A HANDSET IS CONNECTED DIRECTLY TO THE REPEATER
OR THE COAX THAT LEADS TO THE REPEATER.
Important Installation Notes