DSP85 Series Digital Repeater User’s Guide PRODUCT MANUAL WESTELL.COM ©Westell Technologies.
Digital Repeater Line DSP85 Series DISCLAIMER All information and statements contained herein are accurate to the best of Westell Technologies knowledge. Westell Technologies makes no warranty with respect there to, including without limitation any results that may be obtained from the products described herein or the infringement by such products of any property rights of any persons.
Digital Repeater Line DSP85 Series TABLE OF CONTENTS Preface ............................................................................................................................................................................... ix Purpose.................................................................................................................................................................................................................. ix Application ......................................
Digital Repeater Line DSP85 Series 3 4 2.5.3 Power Dividers ............................................................................................................................................................................. 21 2.5.4 Grounding Kit ............................................................................................................................................................................... 21 2.5.5 Directional Couplers .........................................
Digital Repeater Line DSP85 Series B.1.2 700 MHz Upper C Band Plan .................................................................................................................................................. 52 B.1.3 Cellular Frequency Band Plan ................................................................................................................................................. 52 B.1.4 AWS Frequency Band Plan ...........................................................................
Digital Repeater Line DSP85 Series E.2.4 Dual-band D1:D1 Port Configuration ................................................................................................................................. 70 E.2.5 MIMO Port Configuration ........................................................................................................................................................ 70 E.2.6 Single-band D1:D1 Port Configuration ....................................................................
Digital Repeater Line DSP85 Series Figure 4-2: Gender Adapter .............................................................................................................................................................................. 37 Figure 4-3: Tera Term Pro Web Start Up ...................................................................................................................................................... 37 Figure 4-4: Serial Radio Button ..............................................
Digital Repeater Line DSP85 Series Table D-5: Operating Power Parameters ......................................................................................................................................................64 Table G-1: Acronyms and Abbreviations ..................................................................................................................................................... 76 WESTELL.COM © 2016 Westell Technologies 1.877.844.4274 14 June 2016 Doc. No.
Digital Repeater Line DSP85 Series Preface This Preface includes the following: Purpose Application Document Organization Document Conventions Product Registration Information Safety Guidelines Important Safety Information Industry Certifications/Registration Numbers Technical Support Acronyms and Abbreviations Purpose The purpose of this document is to provide a procedure to help experienced technicians/engineers install and commission an in-building wireless enhanc
Digital Repeater Line DSP85 Series Appendix C: LTE Attenuator and Installation Notes – Provides the LTE Attenuator and installation notes including donor and server isolation Appendix D: Mechanical and Electrical Specifications– Provides mechanical and electrical specifications for this product Appendix E: Port Configurations – Details and illustrates the port configurations for each repeater type Appendix F: Mechanical Configurations – Details and illustrates the mechanical configuration for each repeater
Digital Repeater Line DSP85 Series Product Registration Information The product serial number is located on the label on the bottom panel, near the power connectors. Record the serial number, model number, purchase date and point-of-sale company in the boxes in Figure P-1 below. Retain this manual, along with proof of purchase, to serve as a permanent record of your purchase.
Digital Repeater Line DSP85 Series Use the following guidelines when considering separation distances. Place indoor antennas such that, under normal conditions, personnel cannot come within 20 cm (~8 in) from any inside antenna. Adhering to this minimum separation ensures that bystanders cannot exceed RF exposures beyond the maximum permissible limit for uncontrolled exposure. Position outdoor antennas such that, under normal conditions, personnel cannot approach closer than 183 cm (~6 ft.).
Digital Repeater Line DSP85 Series Technical Support If you suspect a malfunction with this product or if you have a technical question, call your dealer or the Westell Technologies In-Building Wireless Support Line at (603) 626-6677, Toll Free (USA) 1-877-844-4274, press option 2 then option 1, or email us at ibwsupport@westell.com. Acronyms and Abbreviations Refer to the Appendix G at the end of this manual for definitions of the acronyms and abbreviations used in this manual. 1 Product Overview 1.
Digital Repeater Line DSP85 Series User gain control (affects all passbands) Automatic gain control Automatic power control Overdrive protection (PA limiting) Under/Over voltage protection Fault protection Alarm notification - local/remote Upgrade support - local/remote External interfaces - USB/ethernet/Serial Re-loadable filters - local/remote Web-based monitoring and control - local/remote Persistent status and error information 1.
Digital Repeater Line DSP85 Series is in the boot up process. A blinking green LED (two seconds on/three seconds off) indicates a filter configuration file is loading. IMPORTANT Do not unplug the repeater while it is in the boot-up process. 1.4 Local Communication Interface Ports To allow monitoring and control, Westell repeaters are equipped with four ports that provide external communication access: one ethernet, one DB-9 serial, and two USB ports.
Digital Repeater Line DSP85 Series 1.7 Ethernet This port is used to provide local or remote access to the GUI. 1.8 Monitoring and Alarms The DSP85 Series can be monitored via an ethernet connection using SNMP, SSH and/or HTTP protocols. Public safety DSP models have dry contacts for traditional alarm panel monitoring as well. 1.9 Circuit Operational Description The repeater uses a single down-conversion/up-conversion scheme. There are multiple RF amplifier stages before each down-converting mixer.
Digital Repeater Line DSP85 Series Figure 1-2: Dual Band Functional Block Diagram WESTELL.COM © 2016 Westell Technologies 1.877.844.4274 14 June 2016 Doc. No.
Digital Repeater Line DSP85 Series Figure 1-3: Single Band Functional Block Diagram WESTELL.COM © 2016 Westell Technologies 1.877.844.4274 14 June 2016 Doc. No.
Digital Repeater Line DSP85 Series 2 Optimizing the System during Installation 2.1 System Setup Considerations Check all cables for shorts and opens. Verify that there are no cables with loose or poor connections. RF leakage could cause oscillation to occur under some conditions. Check the rooftop antenna (donor antenna), if directional, for proper alignment along the calculated compass heading. Typically, the directional antenna is aimed at the same site that your handset uses, but it may not always be.
Digital Repeater Line DSP85 Series 2.3 Important Installation Notes Inadequate isolation between the outside and inside antennas may cause regenerative feedback in the system. This feedback can cause the amplifier to emit a continuous signal at maximum amplitude and, in some cases, interfere with normal operation of the cell site. It is important to consider the layout and placement of the system carefully.
Digital Repeater Line DSP85 Series 2.4.2 Antennas Use omnidirectional antennas indoors, and locate them centrally with respect to the intended coverage area to minimize signal leakage to the outside. Use directional antennas indoors only in special cases when higher gain and directionality would be helpful and RF exposure limits will not be exceeded.
Digital Repeater Line DSP85 Series 2.5.5 2.5.6 Directional Couplers 6 dB - model number ClearLink-DC6/698-2.7K/N 10 dB - model number ClearLink -DC10/698-2.7K/N 15 dB - model number ClearLink -DC15/698-2.7K/N 20 dB - model number ClearLink -DC20/698-2.7K/N 30 dB - model number ClearLink -DC30/698-2.7K/N 19” Rack Shelf 2.5.7 2.5.
Digital Repeater Line DSP85 Series 3 Web-based GUI 3.1 Web-based GUI Session You may access the repeater using a LAN connection and a web browser program such as Internet Explorer, Figure 3-1. Figure 3-1: User Connection Login The repeater ships with the default IP address of 192.168.1.100, but you can change it later if you need to. 1.
Digital Repeater Line DSP85 Series 3.2 System Status After login, the System Status page displays, Figure 3-2. The Navigation Menu on the left side of the page (highlighted in Figure 3-2) shows available operations. Clicking a menu item displays the page for that operation. Figure 3-2: System Status WESTELL.COM © 2016 Westell Technologies 1.877.844.4274 14 June 2016 Doc. No.
Digital Repeater Line DSP85 Series 3.3 Local Network Click Local Network in the System Status left page menu to display the Local Network screen, Figure 3-3, displays. This page allows you to modify the network configuration. The default Boot Mode is Static. Check with your IT department for explanation and approval of the DHCP and DHCP server options you plan to use before you select them. Figure 3-3: Local Network NOTE In repeaters with software version 2.2.
Digital Repeater Line DSP85 Series 3.4 RF Configuration Click RF Configuration in the left page to display and modify the RF Configuration page, Figure 3-4. To change gain settings, select the Uplink only or Uplink and downlink radio buttons. Enter the desired gain value between 53.5 dB and 85 dB. The repeater will not allow values outside this range. Implement change in gain by clicking the Change Settings button at the bottom of the page. Figure 3-4: RF Configuration WESTELL.
Digital Repeater Line DSP85 Series 3.5 Program a Filter Click Program a Filter in the left page menu. The Program a Filter page, Figure 3-5, displays. Change the selected filter in the band/sub-band and modulation options. Deselect undesired bands/sub-bands if they are selected (highlighted). The Clear All button on the selected band deselects all band and sub-bands simultaneously. Clicking the Program button completes the selection and loads the desired filter. This process may take several minutes.
Digital Repeater Line DSP85 Series 3.6 Remote Network If the repeater includes a USB modem kit, click Remote Network in the left page menu. The Remote Network page displays, Figure 3-6. Highlight the carrier on whose network the repeater and modem will be configured and click the Change Settings button. Refer to the documentation included with the modem kit for additional information about modem configuration.
Digital Repeater Line DSP85 Series 3.7 SNMP Configuration To change SNMP settings, click SNMP Configuration in the left page menu. The SNMP Configuration page, Figure 3-7, displays. Check with an IT professional for proper SNMP setting requirements. Figure 3-7: SNMP Configuration 3.8 Time Configuration Click Time Configuration in the left page menu to display the Time Configuration page, Figure 3-8. This page allows you to set the current system time and time zone.
Digital Repeater Line DSP85 Series 3.9 System Health Click System Health in the left page menu to display the System Health page, Figure 3-9. This page displays the current repeater status. Click the Clear Log button to clear LED indicators, alarms and the event log. If required, display the System Health screen, click Trigger Test Alarm and wait for confirmation that the WSP representative that is responsible for monitoring the repeater has been notified of the alarm.
Digital Repeater Line DSP85 Series 3.10 Install and Upload Click Install & Upload in the left page menu to display the Install & Upload page, Figure 3-10. Use this page to perform a software installation or upgrade. Contact Westell Technologies for new software versions. Figure 3-10: Install & Upload IMPORTANT You must click to select the Yes radio button before you click the button. If you do not, the installation will not be performed and an error message will display. WESTELL.
Digital Repeater Line DSP85 Series 3.11 Reboot Click Reboot in the left menu to display the Reboot page, Figure 3-11, which allows you to reboot the repeater. A reboot takes approximately three to five minutes to complete. Figure 3-11: Reboot WESTELL.COM © 2016 Westell Technologies 1.877.844.4274 14 June 2016 Doc. No.
Digital Repeater Line DSP85 Series 3.12 Alarm Configuration Click Alarm Configuration in the left page menu to display the Alarm Configuration page, Figure 3-12. This page displays the current alarm configurations for each band and allows you to make changes by editing alarm settings and the clicking the Apply Settings button. Letters, numbers and hyphens are the only acceptable nomenclature for the location field. Hyphens may not be used as the first or last character.
Digital Repeater Line DSP85 Series 3.13 Email Configuration Clicking Email Configuration in the left page menu displays the Email Configuration page, Figure 3-13. This page allows you to enter up to five e-mail addresses to which the repeater can send specified alarm messages. Alarm messages can be sent only when the repeater is connected via ethernet or wireless modem, and e-mail alarm notification or remote networking are enabled. The software will not allow you to enter invalid characters in any field.
Digital Repeater Line DSP85 Series 3.14 Log Configuration Click Log Configuration to display the Log Configuration page, Figure 3-14. This page provides you with the ability to change three aspects of the way log files are created and stored: Log Rotate Frequency, Log Rotate File Size and Log Rotate File Count. Enter the desired settings for each and click the Configure Logs button to save the settings. Figure 3-14: Log Configuration WESTELL.COM © 2016 Westell Technologies 1.877.844.
Digital Repeater Line DSP85 Series 3.15 Account Credentials Clicking Account Credentials in the left page menu displays the Account Credentials page, Figure 3-15. On this page, you can create a new account or reset the repeater password. The old account is removed when the new account is created. If you need to recover a password you have set, contact Westell Technologies technical support line at 1.877.844.4274, Option 2, then Option 1 for assistance. Figure 3-15: Account Credentials WESTELL.
Digital Repeater Line DSP85 Series 4 Console Interface 4.1 Text Menu Interface (Local Access) To gain local access to the repeater TMI, also known as the console interface, connect a null modem serial cable as shown in Figure 4-1, from the serial connector of the laptop to the serial port on the repeater. This connector is labeled COM. In some cases, if the gender of the connector is not the same as the connectors shown in Figure 4-1, a gender adapter (optional), Figure 4-2 may also be required.
Digital Repeater Line DSP85 Series 1. Select the Serial radio button and click OK, Figure 4-4. Figure 4-4: Serial Radio Button NOTE It may be necessary, to determine which COM port your computer uses for the communications port. Do this in by viewing the system properties section of the control panel using device manager. In this case, the communications port is COM 1. This is not to be confused with the serial port on the bottom panel of the repeater that is also labeled COM 1. 2. Click OK.
Digital Repeater Line DSP85 Series 4. Configure the terminal program for the correct COM port, Figure 4-6. a. Under the Port drop-down list, select COM 1. b. Under the Baud rate drop-down list, select 115200. Figure 4-6: Serial Port Setup 5. After completing the serial port changes, click OK. A dialog displays, prompting you to enter a user name and password. 6. Enter a username and password and press the Enter key. The TMI Main Menu displays, Figure 4-7.
Digital Repeater Line DSP85 Series Figure 4-7: TMI Menus WESTELL.COM © 2016 Westell Technologies 1.877.844.4274 14 June 2016 Doc. No.
Digital Repeater Line DSP85 Series When you select an item in the Set Parameter menu, a sub-menu expands to allow configuration of the selected parameter. For example, Selecting 1 - Adjust Gain in the Link Configuration menu, displays the Links: menu shown in Figure 4-8. Figure 4-8: Adjust Gain Selecting option (1) downlink in the Links: menu displays the current user gain, Figure 4-9. Change the gain value by entering the desired gain value at the prompt.
Digital Repeater Line DSP85 Series All other sub-menu items function in much the same way as the Adjust Gain item. Some of the items will offer additional selections and will be self-explanatory. Figure 4-10 is one example of these additional options. This menu displays when (3) Filter Programming is selected. Figure 4-10: Selecting Filter Programs IMPORTANT Navigate to File>Disconnect to terminate a session. If you do not, the port may become disabled and the system will need to be rebooted. 4.
Digital Repeater Line DSP85 Series When the Tera Term application opens, the window in Figure 4-11 displays. Figure 4-11: Default IP Address 1. Change the default host IP address to the IP address of the repeater to be controlled. In the case of a new install, the default address is 192.168.1.100 and has been assigned at the factory. a. 2. Select Service>Telnet. The TCP port must be 23. Click OK. The login screen, Figure 4-12, displays. Figure 4-12: Login Screen 3. Enter the username and password.
Digital Repeater Line DSP85 Series 4. After you enter the password, press Enter. The main menu, Figure 4-13, displays. Telnet and serial sessions both provide access to the same TMI. Figure 4-13: Main Menu 4.3 Modem Interface (Remote Access with Login) If the repeater is properly equipped, you may use a modem to gain remote access to the repeater. A selection of modems are available as options. After you have installed and activated the modem, you can access it from any web browser.
Digital Repeater Line DSP85 Series 4.4 Additional Tips Follow the steps in this section to change the TCP/IP settings on your Windows computer. 1. Open your computer’s Control Panel as shown in Figure 4-14. Figure 4-14: Control Panel 2. Click on View network status and tasks, under Network and Internet as shown in Figure 4-15. Figure 4-15: View Network Status and Tasks 3. On the left side, click Change adapter settings as shown in Figure 4-16. WESTELL.COM © 2016 Westell Technologies 1.877.844.
Digital Repeater Line DSP85 Series Figure 4-16: Change Adapter Settings 4. Right click Local Area Connections and select Properties as shown in Figure 4-17. Figure 4-17: Local Area Network 5. Double click Internet Protocol Version 4 (TCP/IPv4), or highlight Internet Protocol Version 4 (TCP/IPv4) and select Properties, Figure 4-18. WESTELL.COM © 2016 Westell Technologies 1.877.844.4274 14 June 2016 Doc. No.
Digital Repeater Line DSP85 Series Figure 4-18: Internet Protocol Version 4 (TCP/IPv4) 6. Click to select the radio button next to Use the following IP address, which will allow you to populate the IP address and Subnet mask fields. In the IP address enter 192.168.1.2, and click OK, Figure 4-19. NOTE The Subnet mask will automatically populate to 255.255.255.0. Figure 4-19: Enter IP Address WESTELL.COM © 2016 Westell Technologies 1.877.844.4274 14 June 2016 Doc. No.
Digital Repeater Line DSP85 Series 7. Click OK, then click OK again. 8. Retry the connection. Use a crossover ethernet cable (supplied) for web interface access. You must verify that the ethernet port on your laptop is powered. If your laptop is on battery power, the ethernet port may be inactive by default. If this is the case, plug the laptop into a 110 VAC source or change the power settings to enable the ethernet port when the laptop is using battery power.
Digital Repeater Line DSP85 Series Appendix A Attenuation and Dynamic Range Guidelines A.1 Donor Port If a repeater is installed in an area with very strong wanted and/or unwanted signals, ensure that the overall signal levels are optimized to be within the best operating range of the repeater. Avoid de-sensing of a nearby base station site. You can accomplish these goals by properly attenuating the antenna port(s) in the path of the donor antenna(s).
Digital Repeater Line DSP85 Series A.3 Dynamic Range Thresholds Table A-1: Dynamic Range Thresholds Input Signal Max Gain Input Signal Max Gain <-45 dBm -44.3 dBm -43.6 dBm -42.9 dBm -42.2 dBm -41.5 dBm -40.6 dBm -39.7 dBm -38.8 dBm -37.9 dBm -37 dBm -36.2 dBm -35.4 dBm -34.6 dBm -33.8 dBm -33 dBm 85 dB 84 dB 83 dB 82 dB 81 dB 80 dB 79 dB 78 dB 77 dB 76 dB 75 dB 74 dB 73 dB 72 dB 71 dB 70 dB -32.2 dBm -31.4 dBm -30.6 dBm -29.8 dBm -29 dBm -28.2 dBm -27.4 dBm -26.6 dBm -25.8 dBm -25 dBm -24.
Digital Repeater Line DSP85 Series Appendix B Band Plans and Filter File Naming Conventions B.1 Frequency Band Plans B.1.1 700 MHz Lower A, B and C Band Plan Figure B-1: 700 MHz Lower A, B and C Band Plan WESTELL.COM © 2016 Westell Technologies 1.877.844.4274 14 June 2016 Doc. No.
Digital Repeater Line DSP85 Series B.1.2 700 MHz Upper C Band Plan Up Link (MHz) 776 781.5 787 Dow n Link (MHz) 746 751.5 757 C0 UL776-787 DL746-757 C1 UL776.5-786.5 DL746.5-756.5 Figure B-2: 700 MHz Upper C Band Plan B.1.3 Cellular Frequency Band Plan Uplink (MHz) 824 825 Dow nlink (MHz) 869 A” UL 824-825 DL 869-870 870 835 845 846.5 849 880 890 891.5 894 A B UL 825-835 DL 870-880 UL 835-845 DL 880-890 A’ B’ UL 846.5-849 DL 891.5-894 UL 845-846.5 DL 890-891.
Digital Repeater Line DSP85 Series B.1.
Digital Repeater Line DSP85 Series B.1.6 US PCS Frequency Band Plan Uplink (MHz) 1850 Downlink (MHz) 1930 1870 1945 1950 B0 UL 1850-1865 DL 1930-1945 UL 1870-1885 DL 1950-1965 A2 A1 UL 1857.5-1865 DL 1937.5-1945 A3 A4 A5 UL 185 0-185 5 UL 185 5-186 0 UL 186 0-186 5 DL 193 0-193 5 DL 193 5-194 0 DL 194 0-194 5 A8 UL 1850-1852.5 DL 1930-1932.5 UL 1852.5-1855 DL 1932.5-1935 UL 1855-1857.5 DL 1935-1937.5 B2 A9 A10 A11 D2 UL 1857.5-1860 DL 1935-1937.5 UL 1860-1862.5 DL 1940-1942.
Digital Repeater Line DSP85 Series B.2 Filter File Naming Conventions B.2.1 700 MHz Filter Naming Convention Westell Technologies digital repeaters use an alphanumeric file naming convention for its filter files. The descriptions below will allow you to understand the methodology to determine the desired file for your application.
Digital Repeater Line DSP85 Series B.2.
Digital Repeater Line DSP85 Series B.2.
Digital Repeater Line DSP85 Series B.2.
Digital Repeater Line DSP85 Series US PCS sub-blocks Uplink Downlink A2 1850-1857.5 1930-1937.5 A1 1857.5-1865 1937.5-1945 A3 1850-1855 1930-1935 A4 1855-1860 1935-1940 A5 1860-1865 1940-1945 D2 1865-1867.5 1945-1947.5 D1 1867.5-1870 1947.5-1950 B2 1870-1877.5 1950-1957.5 B1 1877.5-1885 1957.5-1965 B3 1870-1875 1950-1955 B4 1875-1880 1955-1960 B5 1880-1885 1960-1965 E2 1885-1887.5 1965-1967.5 E1 1887.5-1890 1967.5-1970 F2 1890-1892.5 1970-1972.5 F1 1892.5-1895 1972.
Digital Repeater Line DSP85 Series B.2.5 Column: Definition: AWS Filter Naming Convention 1 2 Band a=AWS 3 4 5 6 7 8 9 10 11 Mod type Block Sub-block 1 1 Block Sub-block 2 2 Block Sub- block 3 3 Block Sub-block 4 4 g=gsm A-F A-F A-F A-F c=CDMA 0=Full 1-2=Sub 0=Full 1-2=Sub 0=Full 1-2=Sub 0=Full 12 Separator - Variant 0=Standard 1-2=Sub w=WCDMA e=E-UTRA l=LTE u=UMTS AWS example acA1C0E0F2-0 = (AWS band, CDMA mod type, A1, C full, E full, F2 with standard guard band).
Digital Repeater Line DSP85 Series Appendix C LTE Attenuator and Installation Notes C.1 Important LTE Attenuator and Installation Notes - Donor and Server Isolation Inadequate isolation between the outside and inside antennas may cause regenerative feedback in the system. Carefully consider the layout and placement of the system. Set repeater gain well below line of sight donor path loss, as shown in C.1.1 Line of Sight Propagation Path Loss Table.
Digital Repeater Line DSP85 Series Appendix D Mechanical and Electrical Specifications D.1 Digital Repeater Mechanical and Electrical Specifications D.1.1 Mechanical Specifications Table D-1: Mechanical Specifications Parameters Single Band Dual Band 18.5 x 10 x 4.7 in (approx.) 19.25 x 18.6 x 4.7 in (approx.) Repeater Dimensions DSP85/DSP85-201 DSP85N DSP85-250 and 251 20 x 16 x 6 in (approx.) - 19 x 18 x 3.5 in (2U) (approx.) 19 x 18 x 3.5 in (2U) (approx.) 18.63 x 19.25 x 5.
Digital Repeater Line DSP85 Series D.1.2 Electrical Specifications Table D-2: Electrical Specifications Parameters Single Band Dual Band Passband Options 1 MHZ – full band 1 MHZ – full band Linear output power (typical) ½ Watt 27dBm 27dBm 1 Watt 30dBm 30dBm 5 Watts 37dBm 37dBm Noise figure @ max. gain 5.0 dB 5.0 dB Propagation Delay <2.5 microseconds <2.5 microseconds Gain Adjustment Range 30dB, 0.5 dB steps 30dB, 0.5 dB steps VSWR <1.5:1 <1.
Digital Repeater Line DSP85 Series D.1.5 Operating Power Parameters Table D-5: Operating Power Parameters Parameters Specifications Notes Maximum RF input power without damage 10 dBm Linear gain 85 dB Pass band ripple ±1.5 dB Automatic gain control (AGC) 30 dB max range In 0.5 dB steps Manual gain control 53.5 dB to 85 dB In 0.5 dB steps OIP3 41 dBm Measured with two CW tones at 14 dBm/ tone RMS vector error (EVM) 3% max TDMA, EDGE, W-CDMA, CDMA2000 CDMA RHO 0.
Digital Repeater Line DSP85 Series Appendix E Port Configurations E.1 Digital Repeater Port Configurations, Original Series E.1.1 Dual-band D2:D1 Port Configuration Input: Two single-band duplex ports, one from the low-band donor antenna and one from the high-band donor antenna. Output: One dual-band duplex port to the server antennas. Figure E-1: Dual-band D2:D1 Port Configuration E.1.2 Dual-band D1:D2 Port Configuration Input: One dual-band duplex port from dual-band donor antenna.
Digital Repeater Line DSP85 Series E.1.3 Dual-band D2: D2 Port Configuration Input: Two single-band duplex ports, one from the low-band donor antenna and one from the high-band donor antenna. Output: Two single-band duplex ports, one to the low-band server antennas and one to the high-band server antennas. Figure E-3: Dual-band D2: D2 Port Configuration E.1.4 Dual-band D1:D1 Port Configuration Input: One dual-band duplex port from dual-band donor antenna.
Digital Repeater Line DSP85 Series E.1.5 Single-band D1:D1 Port Configuration Input: One single-band duplex port from donor antenna. Output: One single-band duplex port to server antennas. Figure E-5: Single-band D1:D1 Port Configuration E.1.6 Dual-band D2:S4 Port Configuration Input: Two single-band duplex ports from the donor antenna, one from the high-band, one from the low-band. Output: Four dingle-band simplex ports, two uplink, two downlink, one uplink and one downlink for each band.
Digital Repeater Line DSP85 Series E.1.7 Dual-band D1:S4 Port Configuration Input: One dual-band duplex port from dual-band donor antenna. Output: Four single-band simplex ports, two uplink, two downlink, one uplink and one downlink for each band. Figure E-7: Dual-band D1:S4 Port Configuration E.1.8 Single-band D1:S2 Port Configuration Input: One single-band duplex port from donor antenna. Output: Two single-band simplex ports, one for uplink and one for downlink.
Digital Repeater Line DSP85 Series E.2 Digital Repeater Port Configurations E.2.1 Dual-band D2:D1 Port Configuration Input: Two single-band duplex ports, one from the low-band donor antenna and one from the high-band donor antenna. Output: One dual-band duplex port to the server antennas. Figure E-9: Dual-band D2:D1 Port Configuration E.2.2 Dual-band D1:D2 Port Configuration Input: One dual-band duplex port from dual-band donor antenna.
Digital Repeater Line DSP85 Series E.2.3 Dual-band D2:D2 Port Configuration Input: Two single-band duplex ports, one from the low-band donor antenna and one from the high-band donor antenna. Output: Two single-band duplex ports, one to the low-band server antennas and one to the high-band server antennas. Figure E-11: Dual-band D2:D2 Port Configuration E.2.4 Dual-band D1:D1 Port Configuration Input: One dual-band duplex port from dual-band donor antenna.
Digital Repeater Line DSP85 Series E.2.6 Single-band D1:D1 Port Configuration Input: One single-band duplex port from donor antenna. Output: One single-band duplex port to server antennas. Figure E-14: Single-band D1:D1 Port Configuration E.2.7 Dual-band D2:S4 Port Configuration Input: Two single-band duplex ports from the donor antenna, one from the high-band, one from the low-band. Output: Four dingle-band simplex ports, two uplink, two downlink, one uplink and one downlink for each band.
Digital Repeater Line DSP85 Series E.2.8 Dual-band D1:S4 Port Configuration Input: One dual-band duplex port from dual-band donor antenna. Output: Four single-band simplex ports, two uplink, two downlink, one uplink and one downlink for each band. Figure E-16: Dual-band D1:S4 Port Configuration E.2.9 Single-band D1:S2 Port Configuration Input: One single-band duplex port from donor antenna. Output: Two single-band simplex ports, one for uplink and one for downlink.
Digital Repeater Line DSP85 Series Appendix F Mechanical Configurations F.1 DSP85-250 and DSP85-251 Series Mechanical Drawing Figure F-1: DSP85-250 and DSP85-251 Series Mechanical Drawing WESTELL.COM © 2016 Westell Technologies 1.877.844.4274 14 June 2016 Doc. No.
Digital Repeater Line DSP85 Series F.2 DSP85-250 and DSP85-251 Series Mounting The following diagrams illustrate the methods for mounting the repeater(s) in a typical wall or rack installation. Brackets are provided for both options. Rack mounting a repeater requires two brackets mounted to the front corners of each module, Figure F-2. Figure F-2: Rack Mounting Wall mounting uses four brackets, one at each corner.
Digital Repeater Line DSP85 Series Mount the cross band coupler on the wall close enough to the repeater modules to allow the RF jumpers to reach from the CBC to the repeaters. The attachment system used to anchor the CBC to the wall must be able to support at least 8.4 lbs (3.8 kg). Use a wall anchoring system for the repeaters that can support at least 42.lbs (19.05 kg) for each dual band module and 23 lbs (10.43 kg) for each single band add on module.
Digital Repeater Line DSP85 Series Appendix G Acronyms and Abbreviations Table G-1 is a list of acronyms and abbreviations used in this manual.
Digital Repeater Line DSP85 Series WESTELL.COM ©Westell Technologies.