INSTALLATION
When installing WESTERBEKE engines and generators,
it
is important that strict
attention
be
paid to the following information:
CODES
AND
REGULATIONS
Federal regulations, ABYC guidelines and safety codes must be complied with when
installing engines and generators in a marine environment.
SIPHON-BREAK
For installations where the exhaust manifold/water-injected exhaust elbow is close to
or
will be below the vessel's waterline, provisions
must
be
made to install a siphon-break
in the raw water supply hose to the exhaust elbow. This hose
must
be looped a mini-
mum
of
20 in.
(51
cm) above the vessel's waterline. Failure to use a siphon-break
when
the
exhaust manifold injection port is at or below
the
load waterline will result
in raw water damage to the engine
and
possible flooding
of
the
boat.
If
you have any doubt about the position
of
the water-injected exhaust elbow relative to
the vessel's waterline under any
of
the vessel's various operating conditions
or
when
the vessel is not underway,
install a siphon-break. This precaution is necessary to pro-
tect your engine.
NOTE:
A siphon-break requires periodic inspection
and
cleaning to ensure proper oper-
ation. Failure to properly maintain a siphon-break can result in catastrophic engine
damage. Consult the siphon-break manufacturer
for
a proper maintenance schedule.
EXHAUST
SYSTEM
The exhaust hose must
be
certified for marine use. The system must be designed to
prevent water from entering the exhaust under any sea conditions and at any angle
of
the vessel's hull.
A
detailed
40-page
Marine
Installation
Manual
covering
gasoline
and
diesel,
engines
and
generators,
is
available
from
your
WESTERBEKE
dealer.
Engines & Generators