Installation manual

BT
GENERATOR
This
generator
is
a
four-pole;
brushless, self-excited generator
which
requires
only
the
driving force
of
the engine
to
pro-
duce
AC
output.
The copper and laminated iron
in
the exciter
stator
are
responsible
for
the
self-exciting feature of this gen-
erator.
The
magnetic
field
produced causes
an
AC
voltage
to
be
induced
into
the
related exciter rotor windings during rota-
tion.
Diodes
located
in
the
exciter rotor rectify this voltage
to
DC
and
supply
it
to
the
windings of the rotating
field.
This
creates
an
electromagnetic field which rotates through the
windings
of
the
main
stator,
inducing
an
AC
voltage which is
supplied
to
a
load.
A step
down
transformer is connected
in
parallel
to
the
AC
output of
the
main stator. An
AC
voltage
is
produced
in
the
auxiliary windings
of
the transformer and the
main
stator
and
is,
in
turn,
supplied
to
a full-wave bridge rec-
tifier.
The
rectifier produces a
DC
voltage
to
further excite
the
exciter stator windings, enabling the generator
to
produce
a
rated
AC
output.
An
optional solid-state voltage regulator is
available
to
work
in
tandem with
the
transformer regulator
to
produce
a
more
stable
AC
output.
AC
TERMINAL
BOARD
AC
TERMINAL
BOARD
(12
STUD)
BRIDGE
RECTIFIER
A circuit breaker is installed
on
all
WES1ERBEKE
genera-
tOJS.
This circuit breaker will automatically disconnect
gener-
ator power
in
case of
an
electrical overload. The circuit
breaker
can
be manually shut off when servicing
the
genera-
tor
to
ensure
no
power is corning into the boat.
NOTE:
This circuit breaker is available as a WESTERBEKE
add-on kit
for
earlier model generations; contact your
WESTERBEKE dealer.
SHIMS
BT
GENERATOR
SINGLE
PHASE
[6
STUD]
BT
GENERATOR
SINGLE
PHASE
[12
STUD]
COMPOUND
TRANSFORMER
Engines & Generatqrs
37