Installation manual

SPECIFICATIONS
11.5KW
BTD
AC
GENERATOR
(Single
Phase)
Single
Phase
Voltage
Voltage
regulation:
Frequency
regulation:
Rating
(Volts
AC)
60
Hertz
(1800
rpm)
11.5KW
50
Hertz
(1500
rpm)
9.2KW
Generator
Cooling
Air
Requirements
(60
Hertz)
at
1800
rpm
Generator
Compartment
Ambient
Temperature
Recommendations
Brushless,
four-pole,
revolving
field.
Pre-lubricated,
single
bearing
design.
Reconnectable,
single
phase
transformer
regulation
(optional
solid-state
voltage
regulation)
..
120
or
120/240
Volts
-
60
Hertz
230
Volts
-
50
Hertz
±
5%
no
load
to
full
load.
.3
Hertz
(.5%)
no
load
to
full
load.
120
Volts
95.8
Amps
120/240
Volts
95.8/47.9
Amps
230
Volts
40Amps
225
-
250
cfm
(5.66
-
6.37
cmm)
NOTE:
Increase
air
supply
15%
for
50
Hertz
operation
(1500
rpm)
122"F
(50"C)
maximum
NOTE:
Forced
ventilation
should
be
provided
to
maintain
generator
compartment
temperature
below
122"F
(50"C)
AC
GENERATOR
(3
Phase)
General
- 3
Phase
11.5
KW-
60
Hertz
9.2
KW-
50
Hertz
Voltage
- 3
Phase
(60
Hertz)
Voltage
- 3
Phase
(50
Hertz)
Amperage
- 3
Phase
(60
Hertz)
Amperage
- 3
Phase
(50
Hertz)
Generator
Cooling
Air
Requirements
(60
Hertz)
at
1800
rpm
Generator
Compartment
Ambient
Temperature
Recommendations
Brushless
six
pole,
revolving
field.
Sealed
lubricated
single
bearing
design.
12
Lead
reconnectable
for
low
voltage
WYE,
high
voltage
Delta.
Solid
State
voltage
regulator
with
protection
circuitry.
Low
voltage
WYE
High
voltage
WYE
DELTA
High
voltage
WYE
DELTA
Low
voltage
WYE
High
voltage
WYE
DELTA
240volts
480
volts
240
volts
400
volts
230
volts
34Amps
17
Amps
34Amps
High
voltage
WYE
16
Amps
DELTA
29
Amps
225
-
250
cfm
(5.66
-
6.37
cmm)
NOTE:
Increase
air
supply
15%
for
50
Hertz
operation
(1500
rpm)
122"F
(50"C)
maximum
NOTE:
Forced
ventilation
should
be
provided
to
maintain
generator
compartment
temperature
below122'f
(50"C)
SPECIFICATIONS
12.5KW BTDB
AC
GENERATOR
(Single
Phase)
AC
GENERATOR
(3
Phase)
Single
Phase
Brushless,
four-pole,
revolving
field.
General
- 3
Phase
Brushless
six
pole,
revolving
field.
Sealed
Pre-lubricated,
single
bearing
design.
12.6
KW-
60
Hertz
lubricated
single
bearing
design.
12
Lead
Reconnectable,
single
phase
transformer
10.4
KW-
50
Hertz
reconnectable
for
low
voltage
WYE,
high
regulation
(optional
solid-state
voltage
voltage
Delta.
Solid
State
voltage
regulator
regulation)
..
with
protection
circuitry.
Voltage
120
or
120/240
Volts
-
60
Hertz
Voltage
- 3
Phase
Low
voltage
WYE
240volts
220
Volts
-
50
Hertz
(60
Hertz)
High
voltage
WYE
480
volts
Voltage
regulation:
±
5%
no
load
to
full
load.
DELTA
240
volts
Voltage
- 3
Phase
High
voltage
WYE
400
volts
Frequency
regulation:
± 3
Hertz
(5%)
no
load
to
full
load.
(50
Hertz)
DELTA
230
volts
Rating
(Volts
AC)
Amperage
- 3
Phase
Low
voltage
WYE
34Amps
60
Hertz
(1800
rpm)
120
Volts
98.5
Amps
(60
Hertz)
High
voltage
WYE
19
Amps
12.5KW
120/240
Volts
195.8/49.9
Amps
DELTA
34Amps
50
Hertz
(1500
rpm)
230
Volts
40Amps
Amperage
- 3
Phase
High
voltage
WYE
18Amps
10.4KW
(50
Hertz)
DELTA
32Amps
Generator
Cooling
225
-
250
cfm
(5.66
-
6.37
cmm)
Generator
Cooling
225
-
250
cfm
(5.66-
6.37
cmm)
Air
Requirements
Air
Requirements
(60
Hertz)
at
1800
rpm
NOTE:
Increase
air
supply
15%
for
50
Hertz
(60
Hertz)
at
1800
rpm
NOTE:
Increase
air
supply
15%
for
50
Hertz
operation
(1500
rpm)
operation
(1500
rpm)
Generator
Compartment
122"F
(5o•c)
maximum
Generator
Compartment
122•F
(50"C)
maximum
Ambient
Temperature
Ambient
Temperature
Recommendations
NOTE:
Forced
ventilation
should
be
provided
Recommendations
NOTE:
Forced
ventilation
should
be
provided
to
maintain
generator
compartment
to
maintain
generator
compartment
temperature
below122'F
(50"C)
temperature
below122'F
(50"C)
49