Installation manual
PROBLEM
No
AC
voltage
output
at
no
load.
Residual
volta~e
produced
at
no
load
15-
20
volts
A .
Low
AC
voltage
output
at
no
load
60-100
VAC.
High
AC
output
voltage
150
VAC
or
higher.
BE
TROUBLESHOOTING
NOTE:
AC
GENERATOR
TROUBLESHOOTING
MUST
BE
PERFORMED
WITH
ENGINE
OPERATING
AT
60
HERTZ
PROBABLE
CAUSE
1.
Short
or
open
in
the
4.
Open
in
exciter
main
stator
winding.
stator
winding.
2.
Shorted
pozi-resistor
on
exciter
rotor.
5.
Open
in
rotating
freld
winding.
3.
Four
or
more
shorted
or
open
diodes
on
exciter
rotor.
1.
Faulty
voltage
regulator.
2.
Short
or
open
to
wiring
to
voltage
regulator.
3.
Shorted
or
open
main
stator
auxiliary
winding.
1.
Reset
voltage
potentiometer.
4.
Faulty
voltage
regulator.
2.
Open
or
shorted
diodes
in
exciter
rotor
1
to
3
diodes.
5.
Short
in
exciter
stator
winding.
3.
Open
or
shorted
exciter
rotor
winding.
.
6.
Short
In
rotating
field
winding.
1.
Reset
voltage
potentiometer.
2.
Faulty
voltage
regulator.
Unstable
voltage
output.
Engine
Speed
Steady
1.
Adjust
voltage
regulator.
ยท
2.
Faulty
voltage
regulator.
AC
voltage
drop
under
load
1.
Diode(s)
on
exciter
rotor.
60
- 1
00
volts
AC.
breaking
down
when
load
is
applied
(inductive)
1-3
diodes.
Engines & Generators
48