Installation manual

DIGITAL
CONTROL
PANEL
STOP
SEQUENCE
To
stop
the
generator, press the S1DP
button.
The
d,isplay
will cycle thru
the
following text messages
and
shutdown.
Shutting
Down
Waiting
for
operator
Press start to
engage generator
Engine Shutdown
THE
CONTROL
PANEL
WILL
POWER-DOWN
AND
IN
A
FEW
MOMENTS
THE
DISPLAY
WILL
GO
BLANK
FAILURE
LIGHT/SHUTDOWN
If
a problem occurs, the generator
will
shutdown
and
the
FAILURE
light will illuminate red. In addition,
one
of
the
indicator lights will change from green
to
orange
to
reveal
where
the trouble has occurred
and
the
display
will
text
message what
has
happened.
CAUTION: When servicing/changing
DC
components.
The DC power most
be turned off using
either the DC breaker or the battery switch.
CHANGING
FREQUENCY
(DC
breaker
must
be
off)
When
changing
the
generators
frequency
(SO/60Hz)
switch
#f
on
the
ECU
board
must
be
positioned:
ON
lor
50Hz
OFF
lor
60Hz
CONTROL
BOX
INTERNAL
COMPONENTS
.
CAUTION
(WESTERLINK
or
NMEA·2000):
The electronic components in the Digital
Diesels draw a
very small amount
of
amperage (milli-amps)from the
generator's starting battery
when
the
unit is in a static
state. This maybe as
much
as
50
mtlli-amps
for
the system
ECU
and
50
niil~!-ampsfor
each display.
This can he
as
mitch as 72 amp-hours in a months
time with
no
generator use. It is not necessary to be
concerned with
this slight amperage draw during normal
seaso"al use. However,
if
the generator set is not to be
used
for
a
number
of
months, such
as
winter storage, it is
best
10
disconnect the
DC
power
to the generator with a
NMEA-2000 system
-or
shut
off
the .DC breaker
OIl
the
generator's control
boxfor
a WESTERLINK system.
Examples:
Failure
Light
is
red.
Coolant
Temperature
Light
is
orange.
High Engine Temp.
Reset
ECU
to ReStart
Failure
Light
is
red.
Oil
Pressure
Light
is
orange.
Low
Oil Pressure
Reset
ECU
to Restart
When
a failure
occurs,
refer
to
the
troubleshooting
chart,
wiring
diagram,
and
general operating text
in
this
manual
to
assist in solving
the
trouble.
There are
many
combinations
of
messages
that
can
be
displayed but
they
are
all self explanatory
and
the operator
can easily isolate
and
correct the problem should
one
occur.
Before restarting
the
generator,
the
20
amp
DC
circuit
breaker
must be
pushed
to
the
OFF
position,
and
back
to
the
ON
position
to
reset
the
ECD.
Once the problem
is
corrected
and
the generator
is
restarted,
the
LCD
display
will
begin
cycling
again.
LCD
DISPLAY
PANEL
NOTE:
Keep in
mind
that the Westerbc:ke gener:ator maybe
I':;;
..
=J
the
DC
power
supply
for
the vessel's
NMEA~2000
network.
-
...
~~~;
NOTE:
DURING OPERATION THE
COWR
OF
THE LCD
DISPlAY
MAY
VARY.
CAUSED
BY
HEAT.
THIS IS NORMAL
AND
NO CAUSE FOR CONCERN.
8