Installation manual

MAINTENANCE
SCHEDULE
NOTE:
Use the engine hour meter gauge to log
your
engine hours
or
record
your
engine hours
by
rurming time.
CHECK
HOURS
OF
OPERATION
SCHEDULED
EACH
EXPLANATION
OF
SCHEDULED
MAINTENANCE
DAY
50
100
250
500
750
1000 1250
MAINTENANCE
Raw
Water
Pump
0
0
0
Remove
the
pump
cover
and
inspect
impeller,
At
8{}{)
operating hours,
gasket,
cam
and
cover
for
wear.
Check
the
bearings
disassemble and inspect
and
seals
(the
shaft
should
not
wobble).
Lubricate
for overhaul.
when
reassembling.
Coolant
System
0 0
Drain,
flush,
and
refill
cooling
system
with
the
appropriate
antifreeze
mix.
Electric
Fuellifl
Pump
0
0
0 0 0
0
Periodically
check
the
wiring
connections
and
inspect
the
fuel
line
connections.
'Fuellnjeclors
0
Check
and
adjust
injection
opening
pressure
and
spray
condition
(see
ENGINE
ADJUSTMENTS).
'Starler
Molor
0
0
Check
solenoid
and
motor
for
corrosion.
Remove
and
lubricate.
Clean
and
lubricate
the
starter
motor
pinion
drive.
'Preheat
Circuit
0
0
Check
operation
of
preheat
solenoid.
Remove
and
clean
glow
plugs;
check
resistance
(4-6
ohms).
Reinstall
with
anti-seize
compound
on
threads.
'Engine
Cylinder
0
0
Check
compression
pressure
and
timing
Compression
(see
Engine
Adjustments).
'Adjust
the
Valve
Clearances
0
Adjust
Valve
Clearances
(see
ENGINE
ADJUSTMENTS).
'Heat
Exchanger
0
Remove,
have
professionally
cleaned
and
pressure
tested.
'Water
tnjected
Exhaust
0
0
Check
casting
integrity
every
500
hours
of
Elbow
operation.
Replace
a3
needed.
'WESTERBEKE
recommends
this
service
be
performed
by
an
authorized
mechanic.
CAUTION
(WESTERLINK
or
NMEA-20DD):
The electronic componems
ill
the Digital Diesels draw a very small amount
of
amperage (milli-amps)from the
generator's starting battery when
the unit is in a static state. This maybe as much as
50
milli-ampsfor the system
ECU
and
50
milli-amps
for
each display.
This can be
as
much as
72
amp-hours
in
a months time with no generator use. It is no/necessary
fa
be concerned with this slight amperage draw during
normal seasonal use. However,
if
the generator set is not to be used
for
a number
of
months,
.Hlcll
as willter storage, it is best to disconnect the
DC
power
to the generator with a NMEA-2000 system
o(shl#
off
the
DC
breaker on the generators control box
for
a WESTERLlNK system.
NOTE:
Keep
ill
mind that the Westerbeke generator maybe the
DC
power slIpplyfor the vessels NMEA-2000 network.
A
CAUTION:
When
serviCing/changing
DC
components.
the
DC
power
must
be
turned
off
using
either
the
DC
breaker
or
the
battery
switch.
Engines & Generators