Operator`s manual

SYSTEM
SPECIFICATIONS
CONTINUED
...
General
- 3 Phase
12.5 KW - 60 Hertz
9.3 KW
- 50 Hertz
Voltage
- 3 Phase ( 60 Hertz)
Voltage
- 3 Phase (50 Hertz)
Amperage
- 3 Phase (60 Hertz)
Amperage
- 3 Phase (50 Hertz)
AC
GENERATOR:
ENGINE COMBUSTION AIR
REQUIREMENTS
(60 Hertz) AT
1800 rpm
ENGINE COMPARTMENT COOLING
AIR
TUNE UP SPECIFICATIONS
INJECTOR PRESSURE
ENGINE TIMING
Brushless six pole. revolving field.
Sealed lubricated
single bearing design.
12
Lead reconnectable for
low voltage WYE, high voltage Delta.
Solid State
voltage regulator with protection circuitry.
Low voltage WYE
208 volts
High voltage WYE
480 volts
DELTA
240 volts
High voltage WYE
380 volts
DELTA
220 volts
Low voltage WYE
43
Amps
High voltage WYE
18
Amps
DELTA
37 Amps
High voltage WYE
17
Amps
DELTA
30 Amps
32
cfm (.906 cmm)
100-200 cfm (2.83 - 5.66 cmm)
1707 psi (120 kg/cm
2
+
10
kg/cm
2
- 0 kg/cm
2
)
29
WESTERBEKE
GENERATORS