Operator`s manual

Generator
(Ae
Output)
Make sure that the AC output connections within the generator's districution box are tight and in
accordance with the specific
AC
Load Connections diagram found later
in
this manual. (See the "BT
GENERA TOR" section
of
this manaul.)
WARNING
DO NOT smoke or allow an open flame near batteries. Lead acid batteries emit hydrogen, a
highly-explosive gas.
Batteries
Make sure the positive (+) battery connection is connected to the battery connection
of
the starting
solenoid. The negative ( - ) battery connection should be connected
to
the system ground (engine block).
I
WARNING
I
When servicing the battery or checking electrolyte level, wear rubber gloves, a rubber apron, and
eye protection. Battery acid may splash on the skin or into the eyes inadvertently when removing
electrolyte caps.
Check the battery's electrolyte level ans specific gravity to ensure maximum engine starting efficiency.
Make sure the battery's terminals are clean and tight.
Ventilation
The ventilation requirements
of
the generator sets include the following: combustion air is required for the
engine cylinders; cooling air is required for the generator end; and ventilating air is required to clear the
bilges below the generator, as well as the compartment in which the generator is located,
of
potentially
toxic and flammable diesel fumes. Refer
to
the "SYSTEM SPECIFICATIONS" section
of
this manual for
the airflow requirements
of
the generator sets.