Users guide 6196-2230 Galvanic Isolation Transient Protection GSM Modem www.westermo.com © Westermo Teleindustri AB • 2004 • REV.
Contents 1. Legal information 2. Description 3. Safety ............................................................................................................................................... 4 .................................................................................................................................................................. 4 5–8 3.1 GSM specific ........................................................................................................................
6. Care and Maintenance 7. Installation .......................................................................................................................... 11 12–16 7.1 Mounting / Removal ................................................................................................................................... 12 ................................................................................................................................................... 7.2 SIM card .................
1. Legal information The content of this document are provided “as is”. Except as required by applicable law, no warranties of any kind, either express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, are made in relation to the accuracy and reliability or contents of this document.
3. Safety ! ! ! General: Before using this unit, read this manual completely and gather all information on the unit. Make sure that you understand it fully. Check that your application does not exceed the safe operating specifications for this unit. Before installation, maintenance or modification work: Prevent damage to internal electronics from electrostatic discharges (ESD) by discharging your body to a grounding point (e.g. use of wrist strap).
3.1.2 Hospital / Medical environment Do not use the unit in a medical environment such as health care facities. Follow any regulations or rules that instruct you to not use the unit. Medical equipment may be sensitive to RF energy. If the unit is being used together with any medical devices (such as pacemakers, hearing aids, etc.) consult the physician and/or the manufacturer of the device to determine if it is adequately shielded from external RF energy. 3.1.3 Aircraft Do not use the unit in an aircraft.
3.1.8 RF energy The GD-01 US is a low power radio transmitter and receiver. When it is ON, it receives and also sends out radio frequency (RF) signals. Most modern electronic equipment is shielded from RF signals. However, certain electronic equipment may not be shielded against the RF signals from your wireless unit. All radio transmitting devices send signals which may cause interference in different electronic devices.
3.3 FCC/Industry Canada Notice 3.3.1 Statement according to FCC part 15.105 NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.These limits are designed to provide reasonable protection against harmful interference in a residential installation.
5. Specifications GSM services Circuit Switched Data Fax SMS GPRS Asynchronous transparent or non-transparent up to 14.4 kbit/s MNP2 error correction and V.42 bis data compression Fax group 3 (Class 1 and Class 2) 160 characters text or PDU Point to point (MT/MO) Cell broadcast GPRS Class 8, Class B Coding scheme: CS1 to CS4 Power interface GD-01 US Rated voltage Operating voltage Rated current online mode/ idle mode Rated frequency Connection Connector size 12 – 36 VDC (reverse polarity protected) 10.
Mechanical Dimension (WxHxD) Weight Mounting Degree of protection 55 x 100 x 128 mm 0.
6. Care and Maintenance No maintenance is required, as long as the unit is used within the specified conditions. Follow the recommendations below to maintain full operation of unit and to fulfil the warranty obligations. • Do not attempt to disassemble the unit.There are no user serviceable parts inside. • Do not drop, knock or shake the unit, rough handling above the specification may cause damage to internal circuit boards.
7. Installation 7.1 Mounting / Removal ! Before mounting or removing the unit: Prevent damage to internal electronics from electrostatic discharges (ESD) by discharging your body to a grounding point (e.g. use of wrist strap). Hazardous voltage may occur within this unit when connected to power supply. CLICK! Prevent access to hazardous voltages by disconnecting the unit from power supply and all other electrical connections.
7.2 SIM card The SIM card is accessable under the lid on top of the unit.The SIM card is needed for full operation of the unit. ! Warning! Prevent damage to internal electronics from electrostatic discharges (ESD) by discharging your body to a grounding point (e.g. use of wrist strap), before the lid on top of the unit is removed. ! Warning! Do not open connected equipment. Hazardous voltage may occur within this unit when connected to power supply.
7.
7.4.1 Power interface 2-pos screw terminal No. 1 No. 2 Description –VDC +VDC 7.4.2 RS-232 interface, screw terminal Connection in GD-01 US 5-pos screw terminal No. 1 No. 2 No. 3 No. 4 No. 5 Direction Description – Out In Out In Signal ground CTS RTS RD TD 7.4.3 RS-232 interface, 9-pin D-sub Connection Direction No. 1 No. 2 No. 3 No. 4 No. 5 No. 6 No. 7 No. 8 No. 9 Out Out In In Out In Out Out Description DCD RD TD DTR Signal ground DSR RTS CTS RI 7.4.
7.
7.6 Quick Start guide The serial interface default configuration is: … 115.2 kbit/s, 8 databits, no parity and 1 stop bit (please refer to AT+IPR and AT+ICF commands) … RTS / CTS flowcontrol enabled (please refer to AT+IFC command) … DTR signal must be active from the DTE (please refer to AT&Dn command) Follow the steps below to get the unit up and running as quickly as possible: … Make sure the power is disconnected from the unit … Insert a valid SIM-card with correct services enabled (e.g.
8. Functional description The GD-01 US is used for for wireless data transmissions over the public GSM network. It can be used to link PLC:s, data loggers, security and surveillance systems or for data acquisition. The GSM services supported by the Westermo GD-01 US are Circuit Switched Data, Fax, SMS and GPRS. A data communication link can be established to another GSM modem, to an analogue modem or to a digital ISDN adapter.The protocol used when connecting to an analogue modem is V.21,V.22,V.22bis,V.
9. GSM network operators, subscriptions and services The GD-01 US support several services in the GSM network. In order to get the unit to work properly its important that the GSM service used in a specific application also is enabled on the subscription (the SIM card). When ordering a SIM card from a network operator its necessary to confirm that the specific service needed for the application is enabled before trying to set up the communication link.
10.
11. Related documents This installation manual is in related parts based on the following recommendations: … Westermo AT-command guide. … ETSI GSM 07.05: Digital cellular telecommunications system (Phase 2) Use of DTE-DCE interface for Short Message Service (SMS) and Cell Broadcast Service (CBS) … ETSI GSM 07.07: Digital cellular telecommunications system (Phase 2) AT command set for GSM Mobile Equipment (ME) … ITU-T Recommendation V.25 ter Serial asynchronous automatic dialling and control … ETSI GSM 03.
Westermo Data Communications Ltd Unit 14 Talisman Business Centre • Duncan Road Park Gate, Southampton • SO31 7GA Phone: +44(0)1489 580 585 • Fax.:+44(0)1489 580586 E-Mail: sales@westermo.co.uk Westermo Data Communications GmbH Goethestraße 67, 68753 Waghäusel Tel.: +49(0)7254-95400-0 • Fax.:+49(0)7254-95400-9 E-Mail: info@westermo.de Westermo Data Communications S.A.R.L. 9 Chemin de Chilly 91160 CHAMPLAN Tél : +33 1 69 10 21 00 • Fax : +33 1 69 10 21 01 E-mail : infos@westermo.