STRAPPING CHARTS
FCP250
Depth (cm) Depth (in)
Fuel Level
(Litre)
Fuel Level
(US-Gallon)
Fuel Level
(Imp Gallon)
2
0.8
20
5
4
6
2.4
60
16
13
10
3.9
100
27
22
14
5.5
140
37
31
18
7.1
180
48
40
22
8.7
220
58
49
26
10.2
261
69
57
30
11.8
301
79
66
34
13.4
341
90
75
38
15.0
381
101
84
42
16.5
421
111
93
46
18.1
461
122
101
50
19.7
501
132
110
54
21.3
541
143
119
58
22.8
580
153
128
62
24.4
617
163
136
66
26.0
654
173
144
70
27.6
689
182
152
74
29.1
724
191
159
78
30.7
757
200
167
82
32.3
789
208
174
86
33.9
820
217
180
90
35.4
850
225
187
95
37.4
878
232
193
98
38.6
906
239
199
100
39.4
919
243
202
1. Highlighted on the strapping chart is the maximum safe fill level @
95% of the nominal volume. DO NOT FILL ABOVE THIS LEVEL
2. The dip chart volume is taken from the lowest point in the tank.
3. When programming a level monitoring system, the difference in floor
height at the port location (where the instrument is mounted) should
be subtracted from the fill height for each volume increment line to
equate to corresponding fill height at the instrument location.