Installation guide

3
Maintenance Procedures
3-65
Resetting a SPARC Application Processor
4. To backup a specific configuration enter this command:
tar -cvf /dev/rmt/0
/cnt/configs/offline/name-of-config
5. Press the button on the tape drive to eject the tape after the
command has completed.
6. Logout.
Configuration Restore
Procedure for a DAT
Drive
This procedure defines how to restore USD configurations that were
backed up to tape with the tar command. The configurations are
stored in a subdirectory named for the configuration under the
directory /cnt/configs/offline.
1. Login as root.
2. Install a DAT tape.
3. To restore all the configurations on the tape enter this command:
tar -xvf /dev/rmt/0
4. To restore a specific configuration enter this command:
tar -xvf /dev/rmt/0
/cnt/configs/offline/name-of-config
5. Press the button on the tape drive to eject the tape after the
command has completed.
6. Logout.
Resetting a SPARC Application Processor
This section provides information on resetting and shutting down a
SPARC application processor during normal operation.
Shut Down Solaris
Use the following procedure to shut down the operating system on a
SPARC application processor:
1. Log on to a SPARC application processor through the console.
The console is normally only reachable through the serial switch.
2. Issue this command string:
sync;sync;sync;halt