OPERATION
NOTICE
The engine is equipped with a low oil shutdown
switch. If the oil level becomes low, the engine will
shut down and will not start until the oil is filled to the
proper level.
Be sure the engine has the proper oil level before
using. Failure to verify that the engine has the proper
oil level could result in engine damage.
Disconnect all loads from the generator before
starting. Failure to verify all loads are disconnected
prior to starting the generator could result in damage
to the connected appliances.
1. Verify the battery is properly installed and both
batter
y cables are attached (see Installing the
Battery on page 14).
2. Make sure the circuit breakers are properly set (see
Figure 16).
2
3
1
Figure 16 – Circuit Breakers
1 - 240/120V Circuit
Breaker
2 - 120V Circuit
Breaker
3 - Main Circuit
Breaker
3. Move the fuel shutoff valve to the ON position (see
F
igure 17).
Figure 17 – Fuel Shutoff Valve in the ON Position
4. Pull the choke lever to the ON position (see Figure
18).
Figure 18 – Choke Lever
5. Turn the engine control switch to the START
position until the engine starts. Once the engine
starts, release the engine control switch; the switch
will automatically move into the ON position (see
Figure 19).