Technical Literature



      


Cooling Btu/h 23800 28400 35000 40500 47000 56000
SEER 14 14 14 14 14 14
EER 11 11 11 11 11 11
Sound Ratings 73 73 76 76 78 78

Volts-Cycles-Phase (1)
208/230-
60-1
208/230-
60-1
208/230-
60-1
208/230-
60-1
208/230-
60-1
208/230-
60-1
Operating Voltage Range 187 - 253 187 - 253 187 - 253 187 - 253 187 - 253 187 - 253
Total Amps 13.1 14.7 21.5 24.8 28.7 32.8
Delay Fuse - Max. (2) 20 25 40 45 50 60
Min. Circuit Ampacity 15.2 17.2 25.7 29.3 34.2 38.9

Outdoor Coil
Face Area (Ft
2
) 8.95 8.95 8.95 12.54 12.54 14.1
Type MC-23 MC-23 MC-23 MC-23 MC-23 MC-21
PSC
Fan Motor
Fan Motor - Amps 1 1 1.1 1.5 1.5 1.5
RPM 825 825 1100 1100 1100 1100
HP 1/5 1/5 1/8 1/4 1/4 1/4
Fan Blade
Dia - # Blades 20-3 20-3 20-3 20-3 20-3 20-3
SCFM 2400 2400 2400 2800 2800 3000
Compressor
Data
RLA 8.3 9.9 16.6 17.9 21.8 24.3
LRA 50 69 79 112 117 144.2

Indoor Coil
Face Area (Ft
2
) 3.6 3.6 3.6 5.1 5.1 5.8
Type MC-20 MC-20 MC-20 MC-20 MC-20 MC-20
Metering Device
Fixed
Orifice
Fixed
Orifice
Fixed
Orifice
Fixed
Orifice
Fixed
Orifice
TXV
ECM Blower
Amps 3.8 3.8 3.8 5.4 5.4 7
HP 1/2 1/2 1/2 3/4 3/4 1

Oz. 55 58 58 57 70 69

Shipping 242 248 242 297 300 325
Net Weight (lbs.) 230 236 230 283 286 309
(1) Operating Voltage Range: 187v min. - 253v max. Amperage and wire size based on refrgieration system only. See electrical data tables for
supplemental electric heaters.
(2) HACR Type Circuit Breakers may be used.