UL_Casanova 2/17/04 8:31 AM Page 1 UL-ES-Casanova-WH04 OWNER'S MANUAL MANUAL DEL USUARIO Casanova Supreme TM Item # / Ítem No.: 78049 78051 78053 Finish / Acabado: Antique Brass / Latón antiguo Polished Brass / Latón pulido White / Blanco N.W. : 5.6 KGS G.W. : 6.
UL_Casanova 2/17/04 8:31 AM Page 2 UL-ES-Casanova-WH04 SAFETY TIPS OBSERVE THE FOLLOWING: READ AND SAVE THESE INSTRUCTIONS WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR PERSONAL INJURY, MOUNT TO OUTLET BOX MARKED "ACCEPTABLE FOR FAN SUPPORT", AND USE THE OUTLET SCREWS PROVIDED WITH THE OUTLET BOX. MOST OUTLET BOXES COMMONLY USED FOR THE SUPPORT OF LIGHTING FIXTURES ARE NOT ACCEPTABLE FOR FAN SUPPORT AND MAY NEED TO BE REPLACED. CONSULT A QUALIFIED ELECTRICIAN IF IN DOUBT. 1.
UL_Casanova 2/17/04 8:31 AM Page 3 UL-ES-Casanova-WH04 CONSEJOS DE SEGURIDAD HAGA LO SIGUIENTE: LEA Y GUARDE ESTAS INSTRUCCIONES ADVERTENCIA: PARA REDUCIR EL RIESGO DE INCENDIO, DESCARGA ELÉCTRICA O LESIONES PERSONALES, MONTE EL VENTILADOR EN UNA CAJA DE EMBUTIR ROTULADA “ADECUADA PARA VENTILADORES”, Y UTILICE LOS TORNILLOS DE MONTAJE INCLUIDOS CON LA CAJA DE EMBUTIR.
UL_Casanova 2/17/04 8:31 AM Page 4 UL-ES-Casanova-WH04 FEATURES CARACTERÍSTICAS COMBO-MOTOR COMBO-BLADE NOTE: Combo-Blade finishes vary, depending upon model. The Combo-Motor feature allows you to choose between installing 4 or 5 blades onto your ceiling fan. For 4 blade installation, use the inside hole pattern on the motor. To install 5 blades, use the outside hole pattern on the motor. ASPAS DE DOBLE CARA MOTOR DUAL Combo-Blades feature two high quality finishes on one blade.
UL_Casanova 2/17/04 8:31 AM Page 5 UL-ES-Casanova-WH04 PREPARING FOR INSTALLATION ANTES DE LA INSTALACIÓN 1 2 Unpack and inspect fan carefully to be certain all contents are included. Turn off power at fuse box to avoid possible electrical shock. Use metal outlet box suitable for fan support (must support 35 lbs). Before attaching fan to outlet box, ensure the outlet box is securely fastened by at least two points to a structural ceiling member (a loose box will cause the fan to wobble).
UL_Casanova 2/17/04 8:31 AM Page 6 UL-ES-Casanova-WH04 MOUNTING BRACKET INSTALLATION INSTALACIÓN CON SOPORTE DE MONTAJE 2 3 2 4 1 1 2 1 1 Remove the screws and star washers (1) from the bracket as shown above. Loosen (do not remove) the screws (2) from the bracket as shown above. Install mounting bracket to outlet box in ceiling using the screws and washers provided with the outlet box. Remove the screws and lock washers (1) from motor bracket and save for later use.
UL_Casanova 2/17/04 8:31 AM Page 7 UL-ES-Casanova-WH04 MOUNTING MONTAJE 5 1 6 2 2 Holding the motor upright, insert the other end of the motor bracket into the other slot in the mounting bracket (1) and adjust the motor bracket until tabs on each side (2) fall into place in mounting bracket slots. Secure the motor bracket onto the mounting bracket using the screws and lock washers removed in step 4. This will allow hand free wiring.
UL_Casanova 2/17/04 8:31 AM Page 8 UL-ES-Casanova-WH04 WIRING OPTIONS OPCIÓN DE CABLEADO 7 PULL CHAIN WIRING OPTION From Fan: White (common) Black (hot) Blue* (hot) Main (ground) (connect) (connect) (connect) 8 From House: White (common) Black (hot) Green (ground) WALL CONTROL WIRING OPTION From Fan: White (common) Black (hot) Blue* (hot) Main (ground) *Attach blue wire only if attaching light kit with fan.
UL_Casanova 2/17/04 8:31 AM Page 9 UL-ES-Casanova-WH04 MOUNTING MONTAJE 3 9 1 2 10 1 2 The decorative motor housing has two mating slots (1) and two mating holes (2). Position both slots on the motor housing directly under and in line with two screws in the mounting bracket (3). Lift the motor housing, allowing the two screws to slide into the mating slots. Rotate the motor housing clockwise until both screws from the mounting bracket drop into the slot recesses. Tighten screws securely.
UL_Casanova 2/17/04 8:31 AM Page 10 UL-ES-Casanova-WH04 BLADE INSTALLATION INSTALACIÓN DE LAS PALETAS 11 12 2 2 13 1 Attach blade brackets to blades using the blade bracket screws (1), metal washers (2), and fabric washers (3), if provided. NOTE: Some models do not utilize fabric washers (3). Fije los soportes para paletas a las paletas con los tornillos (1), las arandelas de metal (2) y las de tela (3), si corresponde. NOTA: Algunos modelos no utilizan arandelas de tela (3).
UL_Casanova 2/17/04 8:31 AM Page 11 UL-ES-Casanova-WH04 PARTS LIST LISTA DE REPUESTOS # 1 2 3 4 5 6 No. 1 2 3 4 Description 1 . . . . . . . . . . . . . . . . . Mounting Bracket . . . . . . . . . . . . . . . . . Blade Bracket . . . . . . . . . . . . . . . . . Blade . . . . . . . . . . . . . . . . . Fan Speed Switch . . . . . . . . . . . . . . . . . Capacitor . . . . . . . . . . . . . . . . . Hardware Pack 3 2 Descripción . . . . . . . . . . . . . . . . .Soporte de montaje . . . . . . . . . . . .
UL_Casanova 2/17/04 8:31 AM Page 12 UL-ES-Casanova-WH04 OPERATION AND MAINTENANCE Operation Turn on the power and check operation of fan. The pull chain controls the fan speeds as follows: 1 pull - high; 2 pulls - medium; 3 pulls - low; 4 pulls - off. Speed settings for warm or cool weather depend on factors such as room size, ceiling height, number of fans and so on. The slide switch controls direction, forward or reverse. Warm weather/down position - (Forward) Fan turns counterclockwise direction.
UL_Casanova 2/17/04 8:31 AM Page 13 UL-ES-Casanova-WH04 OPERACIÓN Y MANTENIMIENTO Operación Encienda el ventilador y verifique su funcionamiento. La cadenilla de tiro controla las velocidades del ventilador de la siguiente manera: 1 jalón – rápida; 2 jalones - mediana; 3 jalones - lenta; 4 jalones - apagado. Las velocidades para clima cálido o frío dependen de factores como el tamaño de la habitación, la altura del ventilador, el número de ventiladores, etc.
UL_Casanova 2/17/04 8:31 AM Page 14 UL-ES-Casanova-WH04 TROUBLESHOOTING GUIDE If you have difficulty operating your new ceiling fan, it may be the result of incorrect assembly, installation, or wiring. In some cases, these installation errors may be mistaken for defects. If you experience any faults, please check this Trouble Shooting Chart. If a problem cannot be remedied, please consult with your authorized electrician and do not attempt any electrical repairs yourself.
UL_Casanova 2/17/04 8:31 AM Page 15 UL-ES-Casanova-WH04 GUÍA PARA SOLUCIONAR PROBLEMAS Si tiene dificultades para hacer funcionar su nuevo ventilador, podría ser a causa del armado, instalación o cableado incorrectos. En algunos casos, estos errores de instalación podrían ser confundidos con defectos. Si experimenta alguna falla, consulte esta guía para solucionar problemas. Si no puede solucionar el problema, consulte a un electricista autorizado y no intente reparar conexiones eléctricas.
UL_Casanova 2/17/04 8:31 AM Page 16 UL-ES-Casanova-WH04 Westinghouse Lighting Corporation 12401 McNulty Road Philadelphia, PA 19154 U.S.A. Westinghouse Lighting Corporation 12401 McNulty Road Philadelphia, PA 19154 U.S.A.