Owner's Manual

20
FEATURES
CONTROL PANEL FEATURES – 10KPRO
3 54
6 7 8
9
1112 10
1415 13
2
1
Figure 12 – Control Panel Features
1 - Battery Charger Port: Plug the 120-volt
AC charger into this port to charge the
generator battery.
2 - Low Idle Control: With the smart idle switch
in the ON (I) position, if there is no load
present to any of the outlets for 5 seconds
or longer, the engine speed will reduce to
1800 RPM. If a load is applied to any of the
outlets, the engine speed will automatically
increase to 3600 RPM. With the smart idle
control in the OFF (O) position, the engine
will constantly run at 3600 RPM.
3 - 20-Amp Circuit Breakers: Each circuit
breaker limits the current that can be
delivered through the 120-volt duplex outlets
to 20 amps.
4 - 120-Volt, 30-Amp Twist Lock Outlet: The
outlet can supply 120V output up to 30 amps.
5 - 120-Volt, 30-Amp Circuit Breakers: The
circuit breaker limits the current that can be
delivered through the 120-volt outlet to 30
amps.
6 - 120/240-Volt, 50-Amp Twist Lock Outlet:
Outlet can supply either 120V or 240V output.
7 - Data Center: The data center displays
voltage, frequency and accumulated run
time.
8 - 120/240-Volt, 30-Amp Circuit Breakers:
The circuit breakers limit the current that can
be delivered through the 120/240-volt outlet
to 30 amps.
9 - Ground Fault Sensor: The sensor will
scan all the outlets on the control panel for
a ground fault. If a ground fault is detected
from any of the outlets, the sensor will
automatically trip the main circuit breaker.
10 - Ground Terminal: The ground terminal is
used to ground the generator.
11 - Main Circuit Breaker: The main circuit
breaker controls total output of all outlets to
protect the generator.
12 - 120/240-Volt, 30-Amp Twist Lock Outlet
(NEMA L14-30): The outlet can supply
either 120V or 240V output up to 30 amps.
13 - 120-Volt, 20-Amp Duplex Outlets: Each
outlet is capable of carrying a maximum of
20 amps on a single outlet or a combination
of all outlets.
14 - Remote Start Program Button: Use this
button along with the key fob to program the
generator to be started remotely.
15 - Remote Start Indicator Light: The light will
light or flash depending on the status of the
remote start system.