Owner's Manual

31
OPERATION
3. Move the fuel shutoff valve to the ON position (see
Figure 27).
Figure 27 – Fuel Shutoff Valve in the ON Position
NOTICE
This generator is equipped with an automatic
choke for starting. This system is always on and
cannot be turned off. Do not attempt to make
adjustments to the automatic choke or any other
carburetor adjustments. Tampering with the
automatic choke system may void your warranty.
See an authorized Westinghouse service center for
more information.
4. Turn the engine control switch to the ST
ART
position until the engine starts. Once the engine
starts, release the engine control switch; the switch
will automatically move into the ON position (see
Figure 28).
Figure 28 – Engine Control Switch
NOTICE
Failure to release the engine control switch once
the engine starts could result in damage to the
generator.
Never turn the engine control switch to the START
position while the engine is running; this could
damage the generator.
OTE:N If the engine fails to start after 5 seconds,
release the engine control switch. Let the
generator sit idle for 15 seconds and then
repeat step 4. If the cranking speed drops
after each unsuccessful attempt, then the
battery may not be adequately charged.
OTE:N The generator is equipped with a battery
charging feature. Once the engine is
running, a small charge is supplied to
the battery via the battery cables and will
slowly recharge the battery.